Search results for: SIECI MESH
-
Local Mesh Deformation for accelerated parametric studies based on the Finite Element Method
PublicationThis paper presents an approach for enhancing the efficiency of two-dimensional Finite Element Method analysis in parametric studies or optimisation process of microwave components. The new approach involves local mesh deformation applied near the elements that are modified during computations. Since in the proposed approach the topology of the mesh remains unchanged, a new mesh does not have to be generated from scratch when the...
-
Assessment of usefulness of different tacks in laparoscopic ventral hernia repair
PublicationLaparoscopic ventral hernia repair is becoming a popular technique with good results and fast postoperative recovery. The mesh is placed directly under the peritoneum and anchored with transabdominal sutures and tacks. However, the ideal size of the mesh covering the hernia orifice is know, nor the ideal type or amount of tacks has to be described.
-
A 3D-FEM mesh technique for fast analysis of waveguide problems containing rotatable tuning elements
PublicationIn this paper a meshing technique for 3D Finite Element Method is presented. It allows for fast analysis and optimization of the waveguide structures, which contain rotatable tuning elements. In the proposed procedure a thin layer of varying cylindrical mesh buffer is introduced in order to reuse unchanged mesh and FEM matrices in the rest of the domain.
-
Combined numerical and experimental approach to determine numerical model of abdominal scaffold
PublicationA proper junction of the prosthesis and the abdominal wall is important in successful hernia repair. The number of tacks should be balanced to assure appropriate mesh fixation and not to induce post-operative pain. Numerical simulations help to find this balance. The study is aimed at creating a proper numerical model of a knitted surgical mesh subjected to boundary conditions and load occurring in the abdominal cavity. Continuous,...
-
A New Type of Macro-Elements for Efficient Two-Dimensional FEM Analysis
PublicationThis letter deals with a model order reduction technique applicable for driven and eigenvalue problems solved using the finite element method (FEM). It allows one to efficiently compute electromagnetic parameters of structures comprising small features that require strong local mesh refinement. The subdomains of very fine mesh are separated from the global domain as so called macro-elements that undergo model reduction. The macro-elements...
-
BJS-03 DO WE NEED FIXATION OF THE MESH IN LAPAROENDOSCOPIC TECHNIQUES FOR M3 INGUINAL DEFECTS? AN EXPERIMENTAL STUDY
PublicationThe authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. The results showed that mesh fixation is not the only alternative to preventing recurrence in complex defects and that the type of implant seems to be a key factor from the point of view of mechanics and biophysics.
-
Is mesh fixation necessary in laparoendoscopic techniques for M3 inguinal defects? An experimental study.
Publicationrepairs, in case of large direct hernias (M3) mesh fixation is recommended to reduce recurrence risk. Despite lack of highquality evidence, the recommendation was upgraded to strong by expert panel. The authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. Method The authors conducted...
-
Cross-layer mDNS/ARP integration for IEEE 802.11s Wireless mesh Network
PublicationPopularization of mobile computing devices created a need for robust, efficient and ubiquitous methods of communication and network access. At the same time, evolution and standardization of Wireless Local Area Network (WLAN) technologies made them an attractive solution for building of complex network systems. Moreover, growing maturity of WLAN standards such as IEEE 802.11 allows for introduction of WLAN architectures other than...
-
Measures of region failure survivability for wireless mesh networks
PublicationWireless mesh networks (WMNs) are considered as a promising alternative to wired local, or metropolitan area networks. However, owing to their exposure to various disruptive events, including natural disasters, or human threats, many WMN network elements located close to the failure epicentre are frequently in danger of a simultaneous failure, referred to as a region failure. Therefore, network survivability, being the ability...
-
On the necessity of experimental verification of numerical results in biomedical applications
PublicationPorous structures made of metal or biopolymers with a structure similar in shape and mechanical properties to human bone can be easily produced by stereolitography techniques, e.g. selective laser melting (SLM). Numerical techniques, like finite element method (FEM) have great potential in testing new, even the most sophisticated designs, according to their mechanical properties, i.e. strength or stiffness. However, due to different...
-
Mathematical modelling of implant in an operated hernia for estimation of the repair persistence
PublicationThis paper presents mathematical modelling of an implanted surgical mesh used in the repair process of the abdominal hernia. The synthetic implant is simulated by a membrane structure. The author provides a material modelling of the implant based on the dense net model appropriate for technical fabrics. The accuracy of the proposed solution is evaluated by comparing the simulations of the dynamic behaviour of the system with the...
-
Self-Adaptive Mesh Generator for Global Complex Roots and Poles Finding Algorithm
PublicationIn any global method of searching for roots and poles, increasing the number of samples increases the chances of finding them precisely in a given area. However, the global complex roots and poles finding algorithm (GRPF) (as one of the few) has direct control over the accuracy of the results. In addition, this algorithm has a simple condition for finding all roots and poles in a given area: it only requires a sufficiently dense...
-
In vivo performance of intraperitoneal onlay mesh after ventral hernia repair
PublicationBackground: Ventral hernia repair needs to be improved since recurrence, postoperative pain and other complications are still reported in many patients. The behavior of implants in vivo is not sufficiently understood to design a surgical mesh mechanically compatible with the human abdominal wall. Methods: This analysis was based on radiological pictures of patients who underwent laparoscopic ventral hernia repair. The pictures...
-
Application of mesh deformation for modeling of conformal RF components with 3D FEM
PublicationIn this paper, a method of analysis of conformal RF components has been proposed. In this approach, modeling of a curved structure is based on mesh deformation of planar objects rather than the construction of conformal geometry at CSG level. Since the model is represented as a 3D mesh, the deformation only requires the calculation of nodes position in the bent structure. The results of the proposed algorithm have been validated...
-
A PRELIMINARY STUDY ON THE OPTIMAL CHOICE OF AN IMPLANT AND ITS ORIENTATION IN VENTRAL HERNIA REPAIR
PublicationThis paper addresses the problem of ventral hernia repair. The main goals are to find an optimal surgical mesh for hernia repair and to define its optimal orientation in the abdominal wall to minimise the maximum force at the tissue-implant juncture. The optimal mesh is chosen from a set of orthotropic meshes with different stiffness ratios for typical hernia placement in the abdominal area. The implant is subjected to an anisotropic...
-
Fluid–Structure Interaction methods for the progressive anatomical and artificial aortic valve stenosis
PublicationCardiovascular system diseases, as aortic valve stenosis, are the main cause of mortality and morbidity among patients. There is still a room for enhancement of the diagnostic and therapeutic procedures, which will lead to improvement of the treatment. One of the remedies are the computer tools to support the medical diagnoses and prostheses design. The development of a procedure for modeling the aortic valves: anatomical tricuspid...
-
Mesh dependence study for numerical assessment of hydrodynamic characteristics of windsurfing fin
PublicationThe presented research aims to assess the drag coefficient and lift coefficient versus angle of attack curves for windsurfing fin. Special attention in the research was being paid to the evaluation of the stall angle value. The angle of incidence for which the stall occurs was searched, and the sensitivity of the solution for the mesh resolution was studied. The mesh resolution sensitivity analysis was done by systematically decreasing...
-
Interworking and Cross-layer Service Discovery Extensions for IEEEE802.11s Wireless Mesh Standard
PublicationWith the rapid popularization of mobile end-user electronic devices wireless network technologies begin to play a crucial role as networks access technologies. While classic point-to-multipoint wireless access systems, based on fixed infrastructure of base stations providing access to clients, remain the main most popular solution, an increasing attention is devoted to wireless mesh systems, where each connecting client can extend...
-
Impact response of novel layered two stage fibrous composite slabs with different support type
PublicationThe performance of novel Layered Two Stage Fibrous Composite slabs (LTSFC) was pioneered under falling mass collisions using a combined experimental and numerical study. Such LTSFC slabs consist of three layers with and without the insertion of glass fibre mesh between the layers. LTSFC techniques were used to fabricate the composite slabs with three layers including 3%, 1.5%, and 3% of fibre content for the top, middle, and...
-
Mechanical behaviour of the implant used in human hernia repair under physiological loads
PublicationIn laparoscopic operations of abdominal hernias some recurrences still take place, even when applying a surgical mesh. This is usually caused by a failure of the connection between the tissue and the implant. The study deals with the influence of an implant’s orientation on forces in joints, which connect the mesh to human tissues. In the paper, the implant is modelled as a membrane structure within framework of the Finite Element...