Filters
total: 13
Search results for: connection stiffness
-
Load introduction to composite columns revisited—Significance of force allocation and shear connection stiffness
PublicationThe AISC 360-16 Specification recommends that the design shear force between parts of a composite column in the load introduction area shall be calculated based on the force allocation at ultimate limit state. Applicability of this straightforward method to the load levels that usually arise in slender composite columns is questionable, as this capacity-based force allocation is only true when the axial force is equal to the plastic...
-
Numerical and experimental investigation of rotational stiffness of zed-purlins connection with sandwich panels
PublicationA rotational resistant stiffness of the zed-purlins connection with sandwich panels is investigated. A simple finite element method model of the connection is proposed. The numerical analysis of the model performed by ABAQUS software, in physically linear and geometrically nonlinear ranges, leads to the rotational resistant stiffness sought. The numerical solution obtained is verified experimentally. Two variants of distribution...
-
inclinometers results
Open Research DataThe aim of the research project is to determine the rotational stiffness of the connection between the purlin and the part of the truss top chord. The attached files are referred to inclinometers results (four devices, two axis of rotation for each device) placed on 16 specimens (two types of inclinometers location).
-
Strain gauge results
Open Research DataThe aim of the research project is to determine the rotational stiffness of the connection between the purlin and the part of the truss top chord. The attached files are referred to strain gauge results placed on 16 specimens. For the specimens number from 1 to 8 the magnitudes should be multiplied by factor -2 and for the others by factor -1.
-
Strength testing machine results
Open Research DataThe aim of the research project is to determine the rotational stiffness of the connection between the purlin and the part of the truss top chord. The attached files are referred to the forces and displacements obtained from the strength testing machine (two sensors). The 16 specimens were tested on the experimental set up.
-
Experimental and analytical analysis of punching shear in flat slabs supported on column topped with concrete head
PublicationAn experimental laboraatory test of the two series of slab-column elements topped with drop panels of varying sizes is described in this paper. The scope of the paper is to investigate the influence of the drop panel size and stiffness on the behaviour of the connection between the flat slab and the column topped by the concrete head. The impact of the head size and stiffness is analysed analytically and experimentally. The experimental...
-
Joints Of Steel Sandwich Structures
PublicationSteel sandwich structures are perceived as alternatives to single-skin welded structures in the shipbuilding industry due its advantages like significant reduction of mass in relation to typical single skin structure. However, beside problems with their strength properties itself, applications in real structures requires of solving the problem of joining, both for connection sandwich to sandwich as well as sandwiches to single-shell...
-
Three-point bending test of sandwich beams supporting the GFRP footbridge design process - validation
PublicationSome selected aspects concerning material and construction design issues for pedestrian footbridge made of GFRP composite materials are elaborated in this paper. The analysis is focused on validation tests, which are particularly important because of the advanced technology and materials that are used for this innovative bridge. The considered footbridge is a sandwich-type shell structure comprising of PET foam core and outer skins...
-
Modelling of elastic wave propagation in a bolted joint using a thin layer of shell elements
PublicationThere are many mathematical models describing the propagation of elastic waves through the imperfect boundary of two media. They were successfully applied to modelling of high frequency bulk waves and their interaction with local defects. On the other hand, the existing literature models of bolted connections ignore the aspect of imperfect connection between elements. Therefore, this paper presents the concept of application of...
-
Diagnosis of Damage in a Steel Tank with Self-Supported Roof through Numerical Analysis
PublicationThe safety of civil engineering structures is one of the most important issues of building industry. That is why the assessment of the damage-involved structural response has recently become of major concern to engineers. Among a number of different approaches to diagnosis of damage, the method of measuring the changes in natural frequencies is considered to be one of the most effective indicators of global damage. From the practical...
-
Cable-stayed cantilever structures as an expat of unique application in the construction of a building located in seismic area – an author’s project of multifunctional building in Lisbon, Portugal
PublicationThe article presents numerical simulations for the modelling of seismic impact on the structure of unique cantilever cablestayed structure with application of two methods. The Response Spectrum method, in which a spectrum of the structure's responses to an earthquake's impact is generated and the Accelerogram method, in which we generate dynamic load in the form of a diagram of the connection between acceleration and time for...
-
Badania stanu technicznego ścianek szczelnych strony południowej i północnej komory południowej śluzy Dzierżno
PublicationPrace dotyczyły badań nieniszczących łączników (zamków) Paine`a oraz ścianek szczelnych. Ściany boczne komory południowej śluzy Dzierżno zbudowane są ze stalowych pasów blachy o grubości około 16mm i długości 22m połączonych ze sobą wzdłuż dłuższej krawędzi za pomocą zamków Peine`a. System ten umożliwia uzyskanie szczelnego połączenia na całej długości ścianki. Zaawansowany proces korozji spowodował rozszczelnienie połączenia...
-
Analiza porównawcza metod zwiększania nośności i sztywności stalowych, doczołowych węzłów śrubowych.
PublicationInnowacyjna, w porównaniu z dotychczas stosowanym sposobem, metoda obliczania nośności stalowych węzłów została wdrożona wraz z normami europejskimi. Pozwala ona dokładniej odwzo-rować rzeczywistą pracę poszczególnych części węzła, gdyż wynik obliczeń uzależniony jest od znacznie większej liczby zmiennych. Dzięki postępowi technologicznemu w zakresie metalurgii oraz badaniom naukowym obecnie możliwe jest wzmacnianie połączeń...