Potentiometric sensor with lipid-polymer membranes for quality assessment of French red wines
PublicationThe quality of wines resulting from vineyard management is important for consumers due to the taste and price of wines. In this work, the quality of red wines of three vintages has been investigated by potentiometric sensors with six all-solid-state electrodes. Two series of experiments were carried out. The first involved a qualitative analysis of wine of different vintages from freshly opened bottles. The second consisted of...
-
Tuning the sumanene receptor structure towards the development of potentiometric sensors
Publication -
The possibility of the application of a potentiometric sensor with all-solid-state electrodes for the quality control of different natural waters
PublicationThe quality of various natural waters was examined by a new potentiometric sensor with six all solid state electrodes containing an appropriate lipophilic compound in a polymer membrane. Physicochemical parameters such as conductivity and acidity of tested waters were also tested. All waters were neutral or slightly alkaline and contained different ions (e.g., Cl–) due to the place of their sampling (a coastal zone and a moraine...
-
Potentiometric sensor containing set of ion selective electrodes with lipid modified membranes for quality assessment of tested non-alcoholic beverages
PublicationPotentiometric sensors may be a good tool for fast quality control of commercial drinks. In this work, such a sensor, containing a set of ion-selective electrodes with lipid-modified membranes (benzylhexadecyldimethylammonium chloride monohydrate, hexadecylamine, 1-dodecanol, elaidic acid, cholesterol) was used for discrimination and quality control of non-alcoholic beverages, mainly composed of sugar and citric acid. It was found...
-
New bis(azobenzocrown)s with dodecylmethylmalonyl linkers as ionophores for sodium selective potentiometric sensors
PublicationNovel biscrowns 1 and 2 were synthesized from 13-membered azobenzocrown ethers containing bromoalkylenoxy chains in para position relative to the azo group. The synthesized diester molecules are dodecylmethylmalonic acid derivatives differing by the linker length. The synthesized compounds have the potential of being used as sodium ionophores in ion-selective electrodes. They were characterized and used as ionophores in classic...
-
The possibility of application of the potentiometric sensor with all-solid-state electrodes containing lipid-polymer membranes for classification of tested black leaf teas in terms of their quality
PublicationPotentiometric sensor with all-solid-state electrodes containing lipid-polymer membranes for a set of black leaf teas coming from four countries (China, India, Sri Lanka and Kenia) classification was applied. The tested tea samples were reassigned to quality classes marked with numbers I–V according to the information available. The sensor results of tea samples are presented in the form of radar charts. It was observed that, in...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Potentiometric taste sensor application for liquid product taste estimation
PublicationThe principles of taste sense and kinds of tastes (sweet, salty, sour, bitter, umami and fat) have been described. Food quality estimation by taste sense: organoleptic testing and sensory analysis has been presented. The principle of operation of potentiometric sensor composed of several Ion Selective Electrodes or All Solid State Electrodes with polymeric membranes and macromolecular chemical compounds sensitive to substances...
-
INVESTIGATION OF ACIDIC SOLUTIONS BY POTENTIOMETRIC TASTE SENSOR WITH ALL SOLID STATE ELECTRODES
PublicationPotentiometric taste sensors with electrodes containing lipophilic compound / polymer membranes were already used to distinguish commercial liquid products. In this paper a new potentiometric taste sensor consisting of six All Solid State Electrodes (ASSEs) has been presented. Each of the membrane contains a selected lipophilic compound. The set-up consists of a reference electrode and six ASSEs. The inner layer made of a conducting...
-
Investigation of sweet substances of different molecular structure by potentiometric taste sensor with all solid state electrodes
PublicationA five channel potentiometric taste sensor consisting of an array of All Solid State Electrodes (ASSESs) with different lipid-polymer membranes has been developed. The electrodes are constructed of glassy carbon discs with electrochemically deposited poly(3,4-ethylenedioxythiophene) (PEDOT) acting as ion to electron transducer. The outer layer of the electrode is lipid-polymer membrane. Lipid substances immobilized in PVC membranes...
-
Qualitative and Quantitative Analysis of Selected Tonic Waters by Potentiometric Taste Sensor With All-Solid-State Electrodes
PublicationTaste sensor with five all-solid-state electrodes (ASSE) III (third version) was used for qualitative and quantitative analysis of selected tonic waters (J.Gasco, Kinley, Jurajski, Jurajski with citrus flavor, Carrefour, Schweppes Indian Tonic, and Schweppes Bitter Lemon). The results obtained by this taste sensor analyzed with principal component analysis, agglomerative hierarchical clustering methods show that this sensor can...
-
Characterization of various drinking waters by new potentiometric taste sensor with lipid, lipid-like polymer membranes
PublicationA new sensing system comprising five all-solid-state electrodes with lipid, lipid like-polymer membranes was applied for rapid qualitative and quantitative analysis of various drinking waters. The results elaborated by chemometric methods revealed sensitivity to CO2 content in drinking water, suggesting that this sensing system could be used as a taste sensor. The ability of taste sensor to perform quantitative analysis of minerals...
-
INVESTIGATION OF SOUR SUBSTANCES BY FIVE-CHANNEL POTENTIOMETRIC TASTE SENSOR CONTAINING ALL-SOLID-STATE- ELECTRODES (ASSEs)
PublicationAn elaboration of taste sensor for discrimination of different food products is of great importance for food industry. Potentiometric taste sensor containing ion selective electrodes with lipid/polymer membranes has already been applied commercially in food industry. However, time-consuming and demanding preconditioning method of ions selective electrodes as well as maintenance of electrodes’ bodies are disadvantages of this taste...
-
Investigation of sour substances by five-channel potentiometric taste sensor containing all-solid-state-electrodes ( ASSEs)
PublicationAn elaboration of taste sensor for discrimination of different food products is of great importance for food industry. Potentiometric taste sensor containing ion selective electrodes with lipid/polymer membranes has already been applied commercially in food industry. However, time-consuming and demanding preconditioning method of ions selective electrodes as well as maintenance of electrodes’ bodies are disadvantages of this taste...
-
Application of Potentiometric Taste Sensor with All Solid State Electrodes for Distinguishing of Red Dry Wines from Polish and French Vineyards
PublicationOpracowano nowy potencjometryczny czujnik smaku z sześcioma różnymi elektrodami typu All Solid State Electrode (ASSE). Każda z elektrod zawiera dwie warstwy: polimer przewodzący i membranę lipidowo-polimerową, w której rozpuszczone są poszczególne związki lipidowe. Potencjometryczny sensor smaku charakteryzuje się globalną selektywnością. Zastosowano go w celu odróżnienia próbek wytrawnych czerwonych win pochodzących z różnych...
-
Electrocatalytic gas sensor with reference layer
PublicationIn recent years electrochemical gas sensors based on solid state electrolytes have been intensively developed. They are easy to obtain, use and relative durable. Nasicon is one of the most promising materials, which have been used in construction of gas sensors. Most of these devices work in potentiometric or amperometric mode. However, some works are dedicated to sensors working in electrocatalytic mode. Principle of operation...
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublicationGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
The computational methods in the development of a novel multianalyte calibration technique for potentiometric integrated sensors systems
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in small volume samples. One of the key problems related to the preparation of potentiometric integrated sensors systems (PISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim...
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublicationA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...
-
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublicationPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
-
All solid state electrodes taste sensor with modified polymer membranes for discrimination of mineral water with different CO2 content
PublicationA potentiometric taste sensor with All Solid State Electrodes containing five all solid state electrodes with appropriate lipophilic compounds (benzyldimethyltetradecylammonium chloride, dodecyltrimethylammonium bromide, palmitic acid, stearic acid, and phytol) embedded in a polymer membrane was applied for discrimination of mineral water samples differed in CO2 content. Samples of still, slightly sparkling, and sparkling Naleczowianka...
-
TASTE QUALITIES ESTIMATION BY TASTE SENSE AND ELECTROCHEMICAL SENSORS
PublicationThe principles of taste sense and kinds of tastes (sweet, salty, sour, bitter, umami and fat) have been described. Food quality estimation by taste sense: organoleptic testing and sensory analysis has been presented. The principle of operation of potentiom etric sensor composed of several Ion Selective Electrodes or All Solid State Electrodes with polymeric membranes and macromolecular chemical compounds sensitive to substances...
-
Combination of instrumental and qualitative descriptive analysis for evaluation of selected tonic waters quality features
PublicationThe combination of sensory and instrumental analysis was applied for quality assurance of selected tonic waters. The Quantitative Descriptive Analysis (QDA) in terms of fourteen sensory attributes (aroma, astringency, bite, burn, numbing, tongue heaviness, carbonation, mouth coating, sweet taste, sour taste, bitter taste, sweet aftertaste, sour aftertaste, bitter aftertaste) of selected tonic waters was performed by sensory experts....
-
Multianalyte Calibration Methods for Potentiometric Integrated Sensors System for Determination of Ions Concentration in a Body Fluids
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in a small sample volume. One of the key problems related to the preparation of integrated sensors systems (ISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim of the research...
-
Bridge Non-Destructive Measurements Using a Laser Scanning during Acceptance Testing: Case Study
PublicationOwing to the recent proliferation of inventory works on roads and railways, bridge acceptance tests have increased exponentially. These tests’ results are often misinterpreted owing to the use of various measuring equipment types, rendering integrated interpretation problematic. It is also problematic that adjusting the measurement method is difficult when the structure’s response to load is uncertain. Therefore, it is important...