Filters
total: 9193
filtered: 1116
-
Catalog
- Publications 6081 available results
- Journals 988 available results
- Conferences 6 available results
- Publishing Houses 4 available results
- People 167 available results
- Projects 33 available results
- Laboratories 4 available results
- Research Teams 1 available results
- Research Equipment 2 available results
- e-Learning Courses 175 available results
- Events 57 available results
- Open Research Data 1675 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: CRIMINAL LAW
-
Determination of flow properties of a serial connection of a pressure relief valve (C=5.3, b=0.38) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=7.3, b=0.49) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Accidents, victims and risk levels on regional roads in pomorskie voivodeship, 2017-2019 - Medium to High and high road sections
Open Research DataData contain road sections with the highest number of accidents and victims on regional roads (voivodeship roads) in pomorskie voivodeship in 2017-2019. Measures used to assess the level of risk is: minimum 4 accidents or 4 seriously injured or fatalities per one kilometer (5 classes: low, low to medium, medium, medium to high, high):
-
2 Latin letters by Georg Pauli (b.1586-d.1650) - transcription, translation and photographs
Open Research DataThe data set contains two Latin letters by Georg Pauli (b. 1586 – d. 1650) to his brother Adrian (d. 1622) in photographs, transcriptions, and translations into Polish and English. The first letter was sent by Georg from Gdańsk (formerly Danzig) in 1604 when he was still a student at the local Academic Gymnasium. The second one, in turn, was written...
-
X-ray images of Baltic herring. Data analysis
Open Research DataBased on the developed methodology for the: (i) optimal method of catching, (ii) transporting and storing fish, (iii) measuring and (iv) analyzing X-rays images, the existing collection of X-ray images of Baltic herring, caught in October 2002 during the Swedish component of the Baltic International Acoustic Survey (BIAS) in the Baltic proper (ICES...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=6.2, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=7.3, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=7.3, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=3.3, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=6.4, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=7.3, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=3.3, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=6.2, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=6.2, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=3.3, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=6.4, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=6.4, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.80, b=0.25) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.80, b=0.25) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.8, b=0.25) and (C=5.3, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.10, b=0.14) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.1, b=0.14) and (C=4.4, b=0.42) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.70, b=0.32) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.10, b=0.14) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.70, b=0.32) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=4.4, b=0.42) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.80, b=0.25) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.4, b=0.26) and (C=5.3, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.7, b=0.32) and (C=4.4, b=0.42) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.1, b=0.14) and (C=5.3, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=4.4, b=0.42) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.7, b=0.32) and (C=5.3, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.0, b=0.11) and (C=5.3, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.70, b=0.32) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=4.4, b=0.42) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.70, b=0.32) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.8, b=0.25) and (C=4.4, b=0.42) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.80, b=0.25) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.5, b=0.37) and (C=5.3, b=0.38) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=2.10, b=0.14) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a pressure relief valve arranged in-line. Four test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere,...
-
The XAS spectra of O-K edges, Fe-L edges in pristine, La-, and Nb-doped SFM in 3 states: as-prepared, reduced and reoxidized
Open Research DataThis dataset contains the normalized and exported to *.txt spectra for x-ray absorption spectroscopy. The samples analyzed were strontium ferrite molybdate based, doped with lanthanum and niobium. The powders were measured in as-prepared state (denoted in filename as AP), reduced (red) and reoxidized (reox). The filenames are written accordingly: Edge_(optional:...
-
Mechanical properties of cement pastes containing pristine and silica-coated bismuth oxide (Bi2O3) and gadolinium oxide (Gd2O3) structures
Open Research DataExcel file containing raw mechanical (compressive strength) data of cement pastes containing variable amount of Bi2O3, Gd2O3, Bi2O3-SiO2 and Gd2O3-SiO2 structures. Sample designation in the Excel file is in line with sample designation in the manuscript associated with dataset.
-
XRD results of melamine sponges impregnated by DES
Open Research DataThe set includes raw data from XRD analysis of pure melamine sponge and melamine sponges impregnated by:- Eucalyptol:Menthol (1:1)- Eucalyptol:Menthol (1:2)- Eucalyptol:Menthol (1:3)- Eucalyptol:Menthol (1:4)- Eucalyptol:Menthol (1:5)- Thymol:Menthol (1:1)
-
Accidents, victims and risk levels on regional roads in pomorskie voivodeship, 2017-2019 - All accidents
Open Research DataData contain risk classification on regional roads (voivodeship roads) in pomorskie voivodeship in 2017-2019. Measures used to assess the level of risk are (5 classes low, low to medium, medium, medium to high, high):
-
Carbonized Metal-Organic Frameworks-based strucutres with aluminium, phosphorus and nitrogen
Open Research DataThe dataset includes Raman spectra of carbonized Metal-Organic Frameworks (MOF) [acquired on Renishaw] and electrochemical properties of the materials [acquired on EC Lab], which includes techniques such as Linear Sweep Voltammetry (LCV), Electrochemical Impedance Spectroscopy (EIS), Taffel slope and Chronopotentiometry (CP).
-
Vident-real: an intra-oral video dataset for multi-task learning
Open Research DataWe introduce Vident-real, a large dataset of 100 video sequences of intra-oral scenes from real conservative dental treatments performed at the Medical University of Gdańsk, Poland. The dataset can be used for multi-task learning methods including:
-
Data from pizoelectric pressure sensor placed inside PWK pump chamber
Open Research DataThe dataset contains raw data acquired from a piezoelectric pressure sensor placed inside PWK pump chamber. Pumping pressure was 10MPa, displacement was set to 100%, oil temperature was 33C. Columns "Czas" stand for a time in seconds and milliseconds, "Napięcie" stands for Voltage in Volts
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 4-8h.
Open Research DataWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer.Running time: 4-8h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21, #22-#23, #24-#25, #26-#27,...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #24 - #25.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #24 (upper, rotating), #25 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...