Filters
total: 2599
-
Catalog
- Publications 682 available results
- Journals 1 available results
- People 90 available results
- Inventions 8 available results
- Projects 1 available results
- Laboratories 3 available results
- Research Equipment 4 available results
- e-Learning Courses 300 available results
- Events 90 available results
- Open Research Data 1420 available results
displaying 1000 best results Help
Search results for: 304
-
High grade serous carcinoma - Female, 34 - Tissue image [8310729566966561]
Open Research DataThis is the histopathological image of OVARY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade serous carcinoma - Female, 34 - Tissue image [8310729566967371]
Open Research DataThis is the histopathological image of OVARY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified diseases of liver - Female, 30 - Tissue image [3300730069431011]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mixed germ cell tumor - Male, 30 - Tissue image [3301001549112921]
Open Research DataThis is the histopathological image of TESTIS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mixed germ cell tumor - Male, 30 - Tissue image [2270630026316791]
Open Research DataThis is the histopathological image of TESTIS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Inflammatory disease of cervix uteri - Female, 30 - Cell image [2220630014953581]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified diseases of liver - Female, 30 - Tissue image [9200729571537671]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade serous carcinoma - Female, 34 - Tissue image [8310729566962301]
Open Research DataThis is the histopathological image of OVARY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified diseases of liver - Female, 30 - Tissue image [9200729571538311]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mixed germ cell tumor - Male, 30 - Tissue image [227063002631681]
Open Research DataThis is the histopathological image of TESTIS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Iron deficiency anaemia, unspecified - Female, 34 - Cell image [7120730007984591]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (40x magnification) and saved to DICOM format.
-
Mixed germ cell tumor - Male, 30 - Tissue image [2270630026318861]
Open Research DataThis is the histopathological image of TESTIS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mixed germ cell tumor - Male, 30 - Tissue image [227063002631511]
Open Research DataThis is the histopathological image of TESTIS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
ECG measurement from the hand with elbows in the air - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
Other hypertrophic disorders of skin - Female, 30 - Tissue image [8140730001729971]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade serous carcinoma - Female, 34 - Tissue image [8310729566964831]
Open Research DataThis is the histopathological image of OVARY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Erosion and ectropion of cervix uteri - Female, 30 - Tissue image [6190730017332391]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mixed germ cell tumor - Male, 30 - Tissue image [2270630026315901]
Open Research DataThis is the histopathological image of TESTIS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified diseases of liver - Female, 30 - Tissue image [9200729571533261]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade serous carcinoma - Female, 34 - Tissue image [831072956696351]
Open Research DataThis is the histopathological image of OVARY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Inflammatory disease of uterus, unspecified - Female, 30 - Cell image [4140730008823661]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified diseases of liver - Female, 30 - Tissue image [9200729571534531]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mixed germ cell tumor - Male, 30 - Tissue image [227063002631961]
Open Research DataThis is the histopathological image of TESTIS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Candidiasis of vulva and vagina (N77.1*) - Female, 34 - Cell image [3301001549116751]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mixed germ cell tumor - Male, 30 - Tissue image [227063002631281]
Open Research DataThis is the histopathological image of TESTIS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mixed germ cell tumor - Male, 30 - Tissue image [2270630026318371]
Open Research DataThis is the histopathological image of TESTIS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade serous carcinoma - Female, 34 - Tissue image [8310729566965241]
Open Research DataThis is the histopathological image of OVARY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
ECG measurement from the hand with elbows in the air - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
Spray-deposited carbon-nanotube counter-electrodes for dye-sensitized solar cells
PublicationCarbon nanotubes due to their catalytic properties are a promising alternative to platinum counter electrodes (CE) for dye-sensitized solar cells (DSSC). In this study, counter electrodes were made from double-walled carbon nanotube (DWCNT) ink using the spray printing technique and afterwards they were thermally treated at temperatures ranging from 120 to 300 °C. Morphology and structure was studied using scanning electron microscopy...
-
Preparation and characterization of rigid polyurethane -polyglycerol nanocomposite foams
PublicationThis work reports on the preparation of polyurethane–polyisocyanurate (PUR–PIR) foams containing different polyglycerols and layered silicate nanoclays. The rigid polyurethane foams were obtained in a laboratory scale, in a single step method, from a two-component system with a NCO to OH groups ratio equal to two. The reaction mixture consisted of the proper amounts of a commercial oligoetherpolyol, polyglycerol, catalysts, water,...
-
SPEKTROSKOPOWE BADANIA WYŁADOWANIA MIKROFALOWEGO W ŹRÓDLE PLAZMY TYPU KOMORA REZONANSOWA ZASILANA FALOWODOWO
PublicationW pracy przedstawiono wyniki spektroskopowych badań wyładowania mikrofalowego (2,45 GHz) pod ciśnieniem atmosferycznym, generowanego w źródle plazmy typu komora rezonansowa. Gazami roboczymi były: argon, azot oraz metan, a także mieszaniny argon/metan oraz azot/metan. Natężenie przepływu gazu roboczego zmieniano w zakresie od 50 do 100 l/min, natomiast moc mikrofal absorbowanych przez wyładowanie wynosiła od 300 do 4000 W. Zmierzone...
-
Spray deposited carbon nanotubes counter electrodes for dye-sensitized solar cells
PublicationCarbon nanotubes due to their catalytic properties are a promising alternative to platinum counter electrodes (CE) for dye-sensitized solar cells (DSSC). In this study, counter electrodes were made from double-walled carbon nanotube (DWCNT) ink using the spray printing technique and afterwards thermally treated at temperatures ranging from 120 to 300 °C. Morphology and structure was studied using scanning electron microscopy and...
-
Study of the chemical state of Gd in a Ba-La-Gd-Co based ceramic
Open Research DataBarium, Lanthanum, Gadolinium and Cobaltium precursors were used for production of ceramic materials. Samples were produced by standard solid state reaction. Samples were annealed at 300 Celsius degree in wet and dry atmosphere. Annealing takes 72h or 2h. Results of annealing on a Gadolinum were observed by X-Ray photoemission spectroscopy (XPS), OmicronNanotechnology....
-
Karol Federowicz dr inż.
People -
Wojciech Chrzanowski dr hab. inż.
PeopleWojciech Chrzanowski was born in 1952 in Toruń. He completed his studies in Chemical Technology in 1975, getting his MSc in Inorganic Technology (specialty: Anti-Corrosion Protection) At the Faculty of Chemistry, Gdańsk University of Technology (with distinction). Later this year he was employed in the Department of Analytical Chemistry of then Institute of Chemical Engineering and Measuring Techniques, initially as a technical...
-
Charging of the cast iron lapping tools.
PublicationPrzedstawiono technikę i technologię zbrojenia wymuszonego powierzchni docieraków tarczowych. Omówiono konstrukcję przyrządu oraz wyniki badań intensywności zbrojenia docieraków mikroziarnami węglika krzemu. Analizowano docieraki z żeliwa szarego i sferoidalnego oraz mikroziaren o numerze 320 i 300.
-
Total cross section measurements for electron scattering from tin(IV) chloride (SnCl4)
PublicationTotal cross section for electron scattering from SnCl4 molecules has been measured for energies from 0.6 to 300 eV. Obtained results have been compared with total cross sections for electron scattering from other tetrachloride molecules: XCl4 where X=C, Si, Ge.
-
System monitoringu rozdzielnic kampusu Politechniki Gdańskiej
PublicationW artykule opisano koncepcję, realizację programową oraz stanowisko testowe systemu monitoringu rozdzielnic kampusu Politechniki Gdańskiej. Zaproponowano realizację sprzętową oraz opracowano realizację programową systemu monitoringu rozdzielnic dla dwóch budynków: Gmachu Głównego i Centrum Obsługi Technicznej. Ważną cechą opracowanego rozwiązania jest jego skalowalność, gdyż docelowo system monitoringu będzie obejmował wszystkie...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 301 mA. Sample 24
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 301 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,4 V at 562 mA. Sample 71.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,4 V and discharged to 10 mV by constant current 562 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 1650 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 930 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K04
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate folders).Specimen...
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 300 mA. Sample 103.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 300 mA. Sample 103. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...