displaying 1000 best results Help
Search results for: acoustic diffuser
-
Study of Noise Propagation for Small Vessels
PublicationThe paper presents the results of the noise propagation analysis in ship structures tested in a number of AHTS (Anchor Handling Tug Supply) vessels. Statistical Energy Analysis (SEA) based on numerical model developed specially for the purpose of this numerical investigation were conducted. This numerical model enabled the analysis of both the structural elements and the acoustic spaces. For the detailed studies 47 points fixed...
-
Performance of Noise Map Service Working in Cloud Computing Environment
PublicationIn the paper a noise map service designated for the user interested in environmental noise subject is presented. It is based on cloud computing. Noise prediction algorithm and source model, developed for creating acoustic maps, are working in cloud computing environment. In the study issues related to noise modeling of sound propagation in urban spaces are discussed with a special focus on road noise. Examples of results obtained...
-
Pursuing Listeners’ Perceptual Response in Audio-Visual Interactions - Headphones vs Loudspeakers: A Case Study
PublicationThis study investigates listeners’ perceptual responses in audio-visual interactions concerning binaural spatial audio. Audio stimuli are coupled with or without visual cues to the listeners. The subjective test participants are tasked to indicate the direction of the incoming sound while listening to the audio stimulus via loudspeakers or headphones with the head-related transfer function (HRTF) plugin. First, the methodology...
-
DAB vs DAB+ Radio Broadcasting: a Subjective Comparative Study
PublicationIn the age of digital media, delivering high quality content to consumers is one of the most demanding tasks. There exist numerous broadcasting standards, with different pros and cons, and the DAB/DAB (Digital Audio Broadcasting) system is one of the most popular among them. From an engineer’s perspective, efficient resource management under limited bandwidth conditions has always been a challenge. In this paper a subjective quality...
-
In Memoriam Professors Marianna Sankiewicz-Budzyński and Gustaw K.E. Budzyński - Founders of the Polish Audio Engineering
PublicationBiography and scientific achievements of Professors Marianna Sankiewicz-Budzyński and Gustaw K.E. Budzyński - Founders of the Polish Audio Engineering.
-
Subjective and Objective Comparative Study of DAB+ Broadcast System
PublicationBroadcasting services seek to optimize their use of bandwidth in order to maximize user’s quality of experience. They aim to transmit high-quality digital speech and music signals at the lowest bitrate. They intend to offer the best quality under available conditions. Due to bandwidth limitations, audio quality is in conflict with the number of transmitted radio programs. This paper analyzes whether the quality of real-time digital...
-
Modelling and Measurement of Folk Guitar: Truss Rod and Strings in Numerical Analysis of Tone
PublicationThe study makes an attempt to model a complete vibrating guitar including its non-linear features, specifically the tension-compression of truss rod and tension of strings. The purpose of such a model is to examine the influence of design parameters on tone. Most experimental studies are flawed by uncertainties introduced by materials and assembly of an instrument. Since numerical modelling of instruments allows for deterministic...
-
Nonlinear Excitation of the Non-Wave Perturbations by the Magnetoacoustic Waves in the Non-Isentropic Plasma
PublicationNonlinear excitation of slow modes by the planar magnetosonic perturbations in a plasma is discussed. Plasma is an open system due to radiation and external heating. This may stipulate enhancement of wave perturbations and hence the acoustical activity of plasma. Plasma is assumed to be a homogeneous ideal gas with infinite electrical conductivity. The straight magnetic field is orthogonal to the velocity of fluid’s...
-
A study on of music features derived from audio recordings examples – a quantitative analysis
PublicationThe paper presents a comparative study of music features derived from audio recordings, i.e. the same music pieces but representing different music genres, excerpts performed by different musicians, and songs performed by a musician, whose style evolved over time. Firstly, the origin and the background of the division of music genres were shortly presented. Then, several objective parameters of an audio signal were recalled that...
-
Inhomogeneity of low-noise wearing courses evaluated by tire/road noise measurements using the close-proximity method
PublicationPerforming numerous analyses of tire/road noise measurements on low-noise pavements during the last several years, the authors observed significant inhomogeneity of the wearing course in numerous cases, while similar problems were almost non-existent when dense pavements were measured. Three main causes of low-noise pavement inhomogeneity can be defined. The first one is imperfections in the technology used for asphalt mix production...
-
Standing Waves in One-Dimensional Resonator Contaning an Ideal Isothermal Gas Affected by the Constant Mass Force
PublicationThe study is devoted to standing acoustic waves in one-dimensional planar resonator which containing an ideal gas. A gas is affected by the constant mass force. Two types of physically justified boundary conditions are considered: zero velocity or zero excess pressure at both boundaries. The variety of nodal and antinodal points is determined. The conclusion is that the nodes of pressure and antinodes of velocity do not longer...
-
Voiceless Stop Consonant Modelling and Synthesis Framework Based on MISO Dynamic System
PublicationA voiceless stop consonant phoneme modelling and synthesis framework based on a phoneme modelling in low-frequency range and high-frequency range separately is proposed. The phoneme signal is decomposed into the sums of simpler basic components and described as the output of a linear multiple-input and single-output (MISO) system. The impulse response of each channel is a third order quasi-polynomial. Using this framework, the...
-
About Unusual Diffraction and Thermal Self-Action of Magnetosonic Beam
PublicationThe dynamics of slightly diverging two-dimensional beams whose direction forms a constant angle θ with the equilibrium straight magnetic strength is considered. The approximate dispersion relations and corresponding links which specify hydrodynamic perturbations in confined beams are derived. The study is dedicated to the diffraction of a magnetosonic beam and nonlinear thermal self-action of a beam in a thermoconducting gaseous plasma....
-
Experiments and FE analyses on airborne sound properties of composite structural insulated panels
PublicationArtykuł przedstawia wyniki doświadczalne i numeryczne odnośnie właściwości akustycznych paneli budowlanych. Jako panele zastosowano płyty kompozytowe konstrukcyjno-izolacyjne CSIP. Obliczenia numeryczne wykonano MES stosując podejście zaproponowane w pakiecie ABAQUS. Wyniki MES porównano bezpośrednio z doświadczeniami. Zaproponowano różne spsoby poprawy właściwości akustycznych paneli.
-
Application a laboratory stand for multi-symptoms tests for high cyclic fatigue of constructional material
PublicationThis paper describes a need of diagnostics present ship plants according to current technical state. In order to reach competent physical quantity describing fatigue of materials by congregated energy. This paper describes using some diagnostics methods (acoustic emission AE, vibration, thermovision, deformation) in order to definition fatigue state of construction material. The author tries to find correlation between measured...
-
Sounding Mechanism of a Flue Organ Pipe—A Multi-Sensor Measurement Approach
PublicationThis work presents an approach that integrates the results of measuring, analyzing, and modeling air flow phenomena driven by pressurized air in a flue organ pipe. The investigation concerns a Bourdon organ pipe. Measurements are performed in an anechoic chamber using the Cartesian robot equipped with a 3D acoustic vector sensor (AVS) that acquires both acoustic pressure and air particle velocity. Also, a high-speed camera is employed...
-
Automatic labeling of traffic sound recordings using autoencoder-derived features
PublicationAn approach to detection of events occurring in road traffic using autoencoders is presented. Extensions of existing algorithms of acoustic road events detection employing Mel Frequency Cepstral Coefficients combined with classifiers based on k nearest neighbors, Support Vector Machines, and random forests are used. In our research, the acoustic signal gathered from the microphone placed near the road is split into frames and converted...
-
The AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters
Open Research DataThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
BADANIA ODBIOROWE ŁUKOWEJ KŁADKI DLA PIESZYCH 10T NAD DROGĄ S8 W WARSZAWIE
PublicationThe paper presents in situ load testing of the newly build footbridge over S8 expressway in Warsaw. The most characteristic thing for the structure is a shape of arch girders, which correspond with adjacent half-tunnel acoustic baffles. The paper consists of description of the structure, results of the in-situ static and dynamic load testing, results of the numerical simulations, comparative analysis and final conclusions on the...
-
Split-Beam Echosounder Data from Puck Bay
PublicationThe acoustic data was collected in 2018–2019 in the Bay of Puck in the seasons: autumn, winter, spring. The data was collected during the day and night using three split-beam echosounders with frequencies of 38 kHz, 120 kHz and 333 kHz at a designated study area not far from the city of Hel, while the ship was sailing. To ensure data quality, the echosounders were calibrated and passive noise was measured.
-
Robust algorithm for active feedback control of narrowband noise
PublicationThe problem of active control of narrowband acoustic noise is considered. It is shown that the proposed earlier feedback control algorithm called SONIC (self-optimizing narrowband interference canceller), based on minimization of the L2-norm performance measure, can be re-derived using the L1 approach. The resulting robust SONIC algorithm is more robust to heavy-tailed measurement noise, such as the αlpha-stable noise, than the...
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [519073004665201]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant lymphoma, large B-cell, diffuse, NOS - Male, 55 - Tissue image [5190730046645881]
Open Research DataThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [5190730046656331]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [7040247104956541]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant lymphoma, large B-cell, diffuse, NOS - Male, 55 - Tissue image [5190730046649041]
Open Research DataThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant lymphoma, large B-cell, diffuse, NOS - Male, 55 - Tissue image [519073004664201]
Open Research DataThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant lymphoma, large B-cell, diffuse, NOS - Male, 55 - Tissue image [5190730046649591]
Open Research DataThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [5190730046655751]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [5190730046659901]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [5190730046659201]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 68 - Tissue image [909072959440871]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [5190730046652631]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant lymphoma, large B-cell, diffuse, NOS - Male, 55 - Tissue image [5190730046644781]
Open Research DataThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant lymphoma, large B-cell, diffuse, NOS - Male, 55 - Tissue image [7040247104959341]
Open Research DataThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [7040247104957181]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant lymphoma, large B-cell, diffuse, NOS - Male, 55 - Tissue image [519073004664761]
Open Research DataThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant lymphoma, large B-cell, diffuse, NOS - Male, 55 - Tissue image [5190730046646681]
Open Research DataThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [5190730046652881]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant lymphoma, large B-cell, diffuse, NOS - Male, 55 - Tissue image [7040247104959211]
Open Research DataThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 68 - Tissue image [9090729594404491]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant lymphoma, large B-cell, diffuse, NOS - Male, 55 - Tissue image [5190730046641891]
Open Research DataThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [5190730046652911]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [5190730046658641]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [5190730046654301]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant lymphoma, large B-cell, diffuse, NOS - Male, 55 - Tissue image [5190730046643161]
Open Research DataThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant lymphoma, large B-cell, diffuse, NOS - Male, 55 - Tissue image [5190730046646441]
Open Research DataThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [5190730046651411]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [5190730046653061]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
EBV positive diffuse large B-cell lymphoma - Female, 70 - Tissue image [5190730046655921]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.