Numerical Model of the Aortic Valve Implanted Within Real Human Aorta
PublicationCardiovascular system diseases are the main cause of deaths in developed and developing countries. The main reasons are myocardial infarction, heart failure, stroke and valvular diseases. These are caused mainly by arteriosclerosis. The valvular diseases involve a significant burden for the health care system and their frequency is rising with the patient age. This work describes the tools and numerical models appropriate for modeling...
-
Flow through a prosthetic mechanical aortic valve: Numerical model and experimental study
PublicationThis research presents a numerical model dedicated for virtual patient diagnostics in the field of synthetic valve implantation. The model operates based on computational fluid dynamics solver with implemented rigid body motion solver. Characteristic indicators related to the prosthetic valve were determined to assess the correctness of cardiac system operation after implantation. A novel approach for dynamic time discretization...
-
Multiscale model for blood flow after a bileaflet artificial aortic valve implantation
PublicationCardiovascular diseases are the leading cause of mortality in the world, mainly due to atherosclerosis and its consequences. The article presents the numerical model of the blood flow through artificial aortic valve. The overset mesh approach was applied to simulate the valve leaflets motion and to realize the moving mesh, in the aortic arch and the main branches of cardiovascular system. To capture the cardiac system’s response...
-
Fluid–Structure Interaction methods for the progressive anatomical and artificial aortic valve stenosis
PublicationCardiovascular system diseases, as aortic valve stenosis, are the main cause of mortality and morbidity among patients. There is still a room for enhancement of the diagnostic and therapeutic procedures, which will lead to improvement of the treatment. One of the remedies are the computer tools to support the medical diagnoses and prostheses design. The development of a procedure for modeling the aortic valves: anatomical tricuspid...
-
General anaesthesia or sedation for percutaneous aortic valve implantation? The questionnaire results and authors’ experience
Publication -
Long-term mortality after transcatheter aortic valve implantation for aortic stenosis in immunosuppression-treated patients: a propensity-matched multicentre retrospective registry-based analysis
PublicationIntroduction Data regarding patients with a previous medical record of immunosuppression treatment who have undergone transcatheter aortic valve implantation (TAVI) are limited and extremely inconclusive. Available studies are mostly short term observations; thus there is a lack of evidence on efficacy and safety of TAVI in this specific group of patients. Aim To compare the in-hospital and long-term outcomes between patients...
-
Late Aortic Remodeling after Endovascular Repair of Complicated Type B Aortic Dissection—TEVAR Protects Only the Covered Segment of Thoracic Aorta
PublicationIntroduction: TEVAR is the preferred way of treatment of complicated type B aortic dissection. The purpose of the study was to assess the impact of TEVAR on aortic remodelling in the thoracic and abdominal segment in long-term follow-up. Methods: 23 patients with complicated type B aortic dissection were treated by TEVAR in years 2004-2012 in our Department. Aortic remodelling was rated based on preoperative and final follow-up...
-
Late subclinical hemolysis and long-term outcomes after aortic valve replacement with On-X mechanical prostheses – a preliminary single-center report
Publication -
Salve
Journals -
Calculations of electron impact ionization cross section for simple biomolecules: formic and acetic acids
PublicationObliczono przekroje czynne na jednokrotną jonizację kwasu mrówkowego oraz kwasu octowego. Obliczenia przeprowadzono używając formalizmu BEB w zakresie energii od progu na jonizację do 400 eV. Wyniki porównano z dostępnymi danymi doświadczalnymi.
-
Comparative in vitro research of the Human Aortic Bioprosthesis
PublicationE valuate of the usefulness and reliability of structures based on the analysis of recorded parameters determining the flow through the Human Aortic Bioprosthesis (HAB) have been dealt with. By flow parameters changes determining the performance environment of prosthesis analyzed change of the motion dynamics of the valve leaflets as a function of pressure, thereby determining the degree of alignment of the prosthesis to the performance...
-
Language Value
Journals -
VALUE IN HEALTH
Journals -
JOURNAL OF HEART VALVE DISEASE
Journals -
Outboard valve material testing
PublicationWykonano analizę przyczyn uszkodzenia korozyjnego zaworu zaburtowego. Sformułowano wnioski.
-
Pharmacokinetics and pharmacodynamics of propofol in patients undergoing abdominal aortic surgery
Publication -
In Vitro Study of a Stentless Aortic Bioprosthesis Made of Bacterial Cellulose
Publication -
Acute hypertensive response in ischemic stroke is associated with increased aortic stiffness
Publication -
Aortic Stiffness Predicts Functional Outcome in Patients After Ischemic Stroke
Publication -
Journal of Creating Value
Journals -
Journal of Value Inquiry
Journals -
Aortic stiffness is not only associated with structural but also functional parameters of retinal microcirculation
Publication -
Association of left atrial fibrosis with aortic excess pressure and white matter lesions
Publication -
Aortic excess pressure and arterial stiffness in subjects with subclinical white matter lesions
Publication -
Cost-Effectiveness of Open Repair of Abdominal Aortic Aneurysms with a Novel Perioperative Protocol
Publication -
Numerical Simulations for Transonic Flow in Control Valve
PublicationResults of numerical simulations for transonic flow in control valve are presented. The valve is the main part of an adaptive pneumatic shock absorber. Flow structure in the valve domain and the influence of the flow non-uniformity in the valve on a mass flow rate is investigated. Numerical simulation results are compared with experimental data.
-
IL-22 modulates inflammatory properties of human primary aortic smooth muscle cells
Publication -
Cost Effectiveness of Open Repair of Abdominal Aortic Aneurysms with a Novel Peri-Operative Bundle
Publication -
Forewarned Is Forearmed: Machine Learning Algorithms for the Prediction of Catheter-Induced Coronary and Aortic Injuries
PublicationCatheter-induced dissections (CID) of coronary arteries and/or the aorta are among the most dangerous complications of percutaneous coronary procedures, yet the data on their risk factors are anecdotal. Logistic regression and five more advanced machine learning techniques were applied to determine the most significant predictors of dissection. Model performance comparison and feature importance ranking were evaluated. We identified...
-
CFD Simulations and Tests of a Prototype Flow Control Valve
PublicationIn this paper a prototype of a flow control valve is described and numerically simulated. The flow control valve is used in hydraulic systems to maintain constant fluid flow despite changing loads of a receiver. The standard construction of this type of valves is modified mainly by eliminating the spring. The prototype consists the hydrostatically unloaded throttle valve and pressure ratio valve substituting pressure difference...
-
Effect of Simultaneous Valve Closures in Hydraulic Piping Systems
PublicationThe paper investigates wave interference (between pressure waves) occurring in simple hydraulic systems. Water hammer was induced by simultaneous closure of three valves located at the reservoirs of a “Y” type hydraulic system. Numerical simulations were carried out with the help of the freeware computer package Allievi enabling the reader to replicate results in a direct manner. The influence of the following quantities has been...
-
ARCTIC
Journals -
Value in Health Regional Issues
Journals -
The effect of 7-ketocholesterol and 25-hydroxycholesterol on the integrity of the human aortic endothelial and intestinal epithelial barriers
Publication -
Noninvasively assessed pulsatility of ascending aortic pressure waveform is associated with the presence of coronary artery narrowing
Publication -
Catheter-induced coronary artery and aortic dissections. A study of the mechanisms, risk factors, and propagation causes
PublicationBackground: Only the incidence, management, and prognosis of catheter-induced coronary artery and aortic dissections have been systematically studied until now. We sought to evaluate their mechanisms, risk factors, and propagation causes. Methods: Electronic databases containing 76,104 procedures and complication registries from 2000– –2020 were searched and relevant cineangiographic studies adjudicated. Results: Ninety-six dissections...
-
Conditional Value-at-Risk Vs. Value-at-Risk to Multi-Objective Portfolio Optimization
Publication -
Failure analysis of the exhaust valve face in diesel marine engine
PublicationThe exhaust valve from marine diesel engine which was damaged after 2000 hours of service was investigated. In order to prolong the service time the valve face was cladded with cobalt base alloy using laser technique. After failure microstructural and chemical analyses reviled that cladding process was conducted improperly. The chemical composition of the clad layer was far from the designed one and what more completely inhomogeneous....
-
Behavior of the exhaust valve cladding face under the service conditions
PublicationPodczas eksploatacji silnika okrętowego kluczowym problemem jest trwałośc zaworów wylotowych a w szczególności wąskiego fragmentu - przylgni grzybka zaworu, która decyduje o szczelności zaworu.Przylgnia wykonana przez laserowe napawanie stopu kobaltu została poddana badaniom w warunkach normalnej eksploatacji silnika L22 przez 2 lata. W tym czasi silnik był zasilany zarówno paliwem lekkim jak i biopaliwem. Po zdemontowaniu głowicy...
-
Hydraulic valve design methodology for hydro turbine control system
PublicationThe control of the turbine and its equipment in a hydroelectric power plant requires the HPU (hydraulic power unit) to deliver large volumes of working fluid in a short time at specific optimum control parameters. The use of typical proportional flow control valves created by manufacturers of hydraulic components in low-pressure control systems is disadvantageous due to high pressure losses in the control chambers. This paper presents...
-
The effect of interleukin-35 on the integrity, ICAM-1 expression and apoptosis of human aortic smooth muscle cells
Publication -
Cathepsin G deficiency reduces periaortic calcium chloride injury-induced abdominal aortic aneurysms in mice
Publication -
Left ventricular ejection fraction and aortic stiffness are independent predictors of neurological outcome in acute ischemic stroke
Publication -
Upgrading low value-added activities in global value chains: a functional specialisation approach
PublicationThis paper aims to identify patterns of functional specialisation (FS) in global value chains (GVCs) and determinants of upgrading them for selected Central Eastern European (CEE) economies. By combing the World Input-Output Database with data on occupations, we reveal a new FS pattern among subgroups of CEEs. Poland and Slovakia have an unfavourable GVC position and specialise in low value-added fabrication function. In contrast,...
-
Wrodzone zwężenie zastawki aortalnej - wyniki leczenia operacyjnego i interwencyjnego, z wykluczeniem krytycznej stenozy aortalnej noworodkowej = Congenitial aortic stenosis - outcomes after surgical treatment and baloon dilatation with exclusion of neonatal critical congenitial aortic stenosis
PublicationOdległe wyniki leczenia wrodzonego zwężenia zastawki aortalnej są ważnym problemem medycznym. Celem pracy była ocena wyników postępowania zabiegowego u dzieci z wrodzonym zwężeniem zastawki aortalnej.
-
Boundary value problems for ODEs.
PublicationPrzedmiotem badań są problemy brzegowe dla równań różniczkowych zwyczajnych.W zależności od parametru lambda [występującego w warunku brzegowym] zdefiniowano ciągi monotoniczne i stosując metodę kwasi linearyzacji pokazano,że przy pewnych założeniach ciągi te są zbieżne do jedynego rozwiązania problemu brzegowego i jest to zbieżność kwadratowa. W pracy zawarte są pewne rozważania dotyczące brzegowych nierówności różniczkowych.
-
Nanotechnology for Enhancement of Food Value
Publication -
Creating Shared Value by the University
PublicationPurpose Works that link creating shared value (CSV) with the university are arising, and there is a hope for a great future of this combination. The main problem with these works is that they are based on the wrong assumptions of what CSV is. The aim of the paper is to properly explain the concept of CSV and match it with university social responsibility (USR) at a strategic level. Design/methodology/approach A literature review...
-
Numerical simulation of axisymmetric valve operation for different outer cone angle
Publication -
Study of structures and properties of the laser cladding exhaust valve after service
PublicationPrzylgnie zaworów wydechowych silnie obciążonego silnika okrętowego zostały pokryte warstwą wykonana ze stopu kobaltu za pomocą techniki napawania laserowego. Tak przygotowane zawory były eksploatowane przez 3000 godzin w silniku Daru Młodzieży. Po tym czasie zostały zdemontowane i poddane szczegółowej analizie. Warunki pracy spowodowały powstanie na powierzchni przylgni warstwy tlenków o różnej grubości, wykazującej skłonność...