Publications
Filters
total: 786
Catalog Publications
Year 2016
-
3D polypyrrole structures as a sensing material for glucose detection
PublicationIn this work, 3D polypyrrole (PPy) structures as material for glucose detection is proposed. Polypyrrole was electrochemically polymerized on platinum screen-printed electrode from an aqueous solution of lithium perchlorate and pyrrole. The growth mechanism of such PPy structures was studied by ex-situ scanning electron microscopy. Preliminary studies show that studied here PPy film is a good candidate as a sensing material for...
-
A new diagnostic IR-thermal imaging method for evaluation of cardiosurgery procedures
PublicationTwo methods for monitoring the state of the myocardium during cardiosurgical interventions based on thermal IR imaging are presented below. These methods, called static thermography and active dynamic thermography (ADT), use information about the distribution of temperature on the surface, and an external excitation source to induce thermal transient processes in a tested object. Recording the time series of thermograms allows...
-
A new diagnostic method for evaluation of cardiosurgery wound healing
PublicationOne of important and still unsolved problems in medicine is the question of objective and quantitative evaluation of post-surgery wound healing. The aim of this research is to analyse possibility and value of using the newly elaborated infrared imaging procedure – Active Dynamic Thermography (ADT) – for quantitative description of wound healing processes in cardiosurgery. Both, classical thermal figures of merit as well as ADT...
-
A novel concept for tissue-metal detection and differentiation using an inductive proximity sensor
PublicationIn this paper a novel application of inductive proximity sensors for detection of living tissue by means of measurements of the coil impedance changes at different frequencies is described. The mathematical analyses utilizing Bessel function estimation include detected object size and its distance from a sensor. The main aim of this study is to prove the possibility of distinguishing between metal objects and living tissues. The...
Year 2024
-
3D-Breast System for Determining the Volume of Tissue Needed for Breast Reconstruction
Publication3D imaging systems can be used to effectively determine breast volumes for surgical applications. This article presents methods for surface reconstruction and volume determination based on the point cloud created by 3D imaging. Such a system would be used to accurately estimate breast volume in patients classified for breast reconstruction surgery at plastic surgery centers. To develop such a system, various methods of determining...
Year 2018
-
A Biofeedback System that Uses the Game to Study Electrical Muscle Activity
PublicationThe aim of this project was to design a system that will allow performing repetitive muscle exercises using a biofeedback device. It is supposed to enhance the motivation and attractiveness of the performed tasks thanks to an interactive game developed for mobile devices with the Android operating system. The built-in calibration mechanisms enable the users to play a game that is independent of their abilities which evens out the...
-
A Meta-Analysis of Pulse Arrival Time Based Blood Pressure Estimation
PublicationThe paper presents a preliminary meta-analysis of the sample correlation between pulse arrival time (PAT) and blood pressure (BP). The aim of the study was to verify sample correlation coefficient between PAT and BP using an affine model BP = a · P AT + b for systolic and diastolic blood pressure. The databases included in the search were the IEEE Xplore Digital Library, Springer Link and Google Scholar. Only papers from 2005 to...
Year 2017
-
A body position influence on ECG derived respiration
PublicationAn influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...
-
A navigation device utilizing body communication channel for mobile wearable systems
PublicationA novel touch sensor utilizing a body communication technology is presented in the paper. The proposed device accepts orders (gestures) only from a person wearing it. Moreover, when comparing it to a similar, however an optical one, it appears as a less power consumable. Preliminary results of its properties examination are presented and discussed. Additionally, the developed sensor allows to measure a human body the electrical...
-
A novel sensor for measuring temperature profile during the thermoablation
PublicationAbstract — A novel approach for monitoring a temperature distribution inside a tissue during thermoablation is presented in the paper. A thermal profile is measured using a set of serially connected thermistors each bypassed by a capacitor. This technique allows a two-wire and simultaneous multi- point measurements using a multi-frequency measurement of electrical impedance. It is...
Year 2014
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
A detector of sleep disorders for using at home
PublicationObstructive sleep apnea usually requires all-ni ght examination in a specialized clinic, under the supervision of a medical staff. Because of those requirements it is an expensive and a non-widely utilized test. Moving the examination procedure to patients’ home with automatic analysis algorithms involved will decrease the costs and make it available for larger group of patients. The developed device allows all-night recordings...
Year 2015
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
Year 2010
-
A Fast Method of Separation of the Noisy Background from the Head-Cross Section in the Sequence of MRI Scans
PublicationThe paper presents a new method of removing the noisy background from the sequence of magnetic resonance imaging (MRl) scans. The sequence of scans is required in order to monitor a passage of a contrast agent through the brain tissue. The scans contain the noisy head-cross data and also the noisy background data. The latter has to be removed and excluded from a further analysis. It is achieved by applying some basic morphological...
Year 2021
-
A MEASUREMENT SYSTEM FOR MONITORING CARDIOVASCULAR EVENTS IN SYNCOPE PATIENTS
PublicationSyncope phenomena is an abrupt and transient loss of consciousness leading to interruption of awareness of one’s surroundings and falls with risk of injury. Syncope is often followed by complete and usually rapid spontaneous recovery. It is said that half of all individuals experience syncopal event at least once during their life. The condition can occur at any age and happens in people with and without other medical problems....
Year 2013
-
A multisensor detector of a sleep apnea for using at home
PublicationDiagnosis of obstructive sleep apnea usually involves polysomnographic analysis, which unfortunately requires overnight stay in a specialized clinic and is very uncomfortable for a patient. This paper describes the method and apparatus for recording a set of signals to detect sleep apnea. The device records the following signals simultaneously: three-channel ECG, respiratory functions, signals from the accelerometer, and snoring...
Year 2006
-
A new OSS design based on parameter sensitivity tochanges in measurements
PublicationW wyniku istniejących silnych ograniczeń praktycznych i etycznych nałożonych na eksperymenty medyczne, procedura estymacji parametrów w diagnozie i terapii jest często zagadnieniem skomplikowanym. Jeśli dane pomiarowe pobierane są w postaci próbek krwi, liczba tych próbek, a także czas obserwacji powinny być zminimalizowane. Optymalizacja eksperymentu polega na optymalizacji odpowiedniego sformułowanego kryterium będącego funkcją...
Year 2019
-
A New Rehabilitation Device for Balance Impaired Individuals
PublicationIn the paper authors present a device designed to improve the rehabilitation process of people with balance impairment. The discussed device (JStep) utilizes a commercially available static standing frame (stander) modified in order to fit force sensing units under the feet and in the pillows around the hips of a patient. While executing rehabilitation tasks, the patient may compensate his balance deficiency by leaning on the pillows...
Year 2007
-
A novel technology of solid oxide fuel cell fabrication
PublicationW pracy przedstawiono metodę wytwarzania wartstw i materiałów elektroceramicznych. Metoda jest kombinacją metod nanoszenia szkieletu z proszków ceramicznych i prekursorów polimerowych. Umożliwia ona otrzymanie zarówno gęstych jak i porowatych warstw i materiałów jednorodnych oraz kompozytowych. W pracy przedstawiono przykłady struktur dla tlenkowych ogniw paliwowych.
Year 2023
-
A review of methods of blood supply to organs of the gastrointestinal tract. State of art
PublicationThe correct assessment of blood supply is essential to eliminate possible postoperative complications. Re-anastomosis of the gastrointestinal tract after its resection must be preceded by the analysis of blood supply to the anastomosed fragments. It is important that the blood supply assessment procedure is reliable but also non-absorbing and, if possible, short. It should also be possible to repeat the procedure due to the need...