prof. dr hab. inż. Bożena Zabiegała
Zatrudnienie
- Profesor w Katedra Chemii Analitycznej
Publikacje
Filtry
wszystkich: 127
Katalog Publikacji
-
Concentrations of monoaromatic hydrocarbons in the air of the underground car park and individual garages attached to residential buildings
PublikacjaThe paper describes the characteristics of a two-level underground car park and three individual garages attached to residential buildings, differing by the resident utilization habits, located in North Poland (Tri-City agglomeration area). The strategy of collecting the analyte samples from air in mentioned enclosed areas, concerning the determination of benzene, toluene, ethylbenzene, o-xylene and p,m-xylenes (BTEX) concentrations...
-
An investigation of selected monoaromatic hydrocarbons released from the surface of polystyrene lids used in coffee-to-go cups
PublikacjaA consumer trend towards the fast preparation of beverages has increased the popularity of hot beverages (especially coffee and tea) available in disposable containers called coffee-to-go cups with fitted polystyrene lids. Lids in contact with hot beverages may release low molecular weight organic compounds into the gaseous phase causing direct exposure of consumers to these compounds during drinking. The paper describes in detail...
-
Real-time monitoring of the emission of volatile organic compounds from polylactide 3D printing filaments
PublikacjaEstablishing the emission profile of volatile organic compounds generated during fused deposition modeling 3D printing using polymer filaments is important in terms of both understanding the processes taking place during thermal degradation of thermoplastics, and assessing the user's exposure to potentially harmful volatiles. However, obtaining detailed, real-time qualitative and quantitative results poses a challenge. In this...
-
Application of the chromatographic retention index system for the estimation of the calibration constants of permeation passive samplers with polydimethylsiloxane membranes
PublikacjaThe paper presents the results of research on the calibration of permeation passive samplers equipped with polydimethylsiloxane (PDMS) membranes using the physico-chemical properties of the analytes. Strong correlations were found between the calibration constants of the samplers and the linear temperature-programmed retention indices of the analytes determined on columns coated with pure PDMS (r2 = 0.914). These correlations...
-
Elicitation strategies for the improvement of essential oil content in Rhododendron tomentosum (Ledum palustre) bioreactor-grown microshoots
PublikacjaRhododendron tomentosum Harmaja, previously Ledum palustre L., is a fragrant plant growing in swampy areas, which is characterized by well-known repellent properties and the anti-arthritic potential. In the present study, R. tomentosum microshoots cultivated in RITA® bioreactor, providing the alternative, environment-independent source of the valuable essential oil, were treated for 7 days with copper and nickel salts, methyl jasmonate,...
-
The miniaturised emission chamber system and home-made passive flux sampler studies of monoaromatic hydrocarbons emissions from selected commercially-available floor coverings
PublikacjaThe estimation of the emission rate of organic compounds released from various types of indoor materials can be performed using stationary environmental test chambers (ETC) classified as ex-situ methods or small-scale portable analytical devices based on the use of passive technique at the stage of analytes sampling from the gaseous phase (in-situ methods). The paper presents results of emissions of selected organic compounds from...
-
The emissions of monoaromatic hydrocarbons from small polymeric toys placed in chocolate food products
PublikacjaThe article presents findings on the emissions of selected monoaromatic hydrocarbons from children's toys placed in chocolate food products. The emission test system involved the application of a new type of microscale stationary emission chamber, μ-CTE™ 250. In order to determine the type of the applied polymer in the manufacture of the tested toys, Fourier transform infrared spectroscopy and thermogravimetric analysis coupled...
-
Mobile Systems (Portable, Handheld, Transportable) for Monitoring Air Pollution
PublikacjaThe monitoring and analysis of atmospheric air pollutants is a rapidly developing branch of analytical chemistry. The in situ analysis of atmospheric air quality using mobile instrumentation is becoming routine. The article provides information on devices used in various kinds of mobile laboratories. It reviews the portable gas chromatographs and handheld devices used for detecting and determining specific harmful substances in...
-
Sample preparation for gas chromatographic determination of halogenated volatile organic compounds in environmental and biological samples
PublikacjaPodstawowym elementem przygotowania próbek środowiskowych i biologicznych do analizy jest etap izolacji i/lub wzbogacania polegający na przeniesieniu analitów z matrycy pierwotnej charakteryzującej się złożonym i często zmiennym składem (próbka oryginalna) do matrycy wtórnej z równoczesnym usunięciem substancji przeszkadzających (izolacja)i zwiększeniem stężenia analitów do poziomu powyżej granicy oznaczalności stosowanego przyrządu...
-
Bioreactor shoot cultures of Rhododendron tomentosum (Ledum palustre) for a large-scale production of bioactive volatile compounds
PublikacjaRhododendron tomentosum Harmaja (Ledum palustre), a peat bog plant from Ericaceae family, has been used in traditional medicine as the anti-arthritis agent. Although modern researches confirm its anti-inflammatory properties, it remains threatened by habitat degradation and possibilities to collect this endangered species from its natural environment for further biological activity studies are limited. Therefore, R. tomentosum...
-
Human hair as a biomarker of human exposure to persistent organic pollutants (POPs)
PublikacjaThe main aim of this article is to investigate the possibility of using human hair as a biomarker with particular emphasis on persistent organic pollutants (POPs). We report previous results of studies of this topic. We critically review the available information on analytical procedures applied during analysis of human hair. Finally, we discuss future trends and possibilities arising from hair analysis.
-
α-Pinene, 3-carene and d-limonene in indoor air of Polish apartments: The impact on air quality and human exposure
PublikacjaMonoterpenes are among most ubiquitous volatile organic compounds (VOCs) to be detected in indoor air. Since the quality of indoor air is considered important for inhabitants' well-being, the present study aimed at investigating impact of human activity on levels of selected monoterpenes applying passive sampling technique followed by thermal desorption and gas chromatography coupled mass spectrometry. One of the objectives of...
-
The influence of meteorological conditions and anthropogenic activities on the seasonal fluctuations of BTEX in the urban air of the Hanseatic city of Gdansk, Poland
PublikacjaThe results of studies conducted in Gdansk in the period from January to December 2013 and focused on the determination of BTEX in the atmospheric air are presented. At the stage of the isolation and/or enrichment of analytes from the gaseous medium, a passive sampling technique—Radiello® diffusive passive samplers, was applied. The time-weighted average annual concentration of benzene, toluene, ethylbenzene, and total xylenes...
-
Measurement of benzene concentration in urban air using passive sampling
PublikacjaAbstract The concentration of benzene in urban air in theTri-City area of Poland (Gdańsk-Sopot-Gdynia, andTczew) was assessed using diffusive passive samplers (Rad-iello). Samples were collected during a four-year monitoringcampaign (2007-2010) at selected monitoring stations man-aged by the Agency of Regional Air Quality Monitoring inthe Gdańsk Metropolitan Area (ARMAAG) Foundation.The performance of the passive samplers was investigatedin...
-
Application of passive sampling technique in monitoring research on quality of atmospheric air in the area of Tczew, Poland.
PublikacjaThis paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. Analytical procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID)...
-
Solventless sample preparation techniques based on solid- and vapour-phase extraction
PublikacjaThe main objective of this review is to critically evaluate recent developments in solventless sample preparation techniques. The potential of a variety of sample preparation techniques based on solid- and vapour-phase extraction techniques is evaluated. Direct thermal extraction and derivatization processes to facilitate the extraction of analytes in different areas are included. The applicability, disadvantages and advantages...
-
The effect of anthropogenic activity on BTEX, NO2, SO2, and CO concentrations in urban air of the spa city of Sopot and medium-industrialized city of Tczew located in North Poland
PublikacjaThe major goal of the present study is to compare the air quality of two urban locations situated in Northern Poland – the spa City of Sopot and the medium-industrialized city of Tczew using chemometric methods. As a criterion for the assessment of atmospheric air quality, measurements of benzene, toluene, ethylbenzene and total xylenes were used (collected from atmospheric air using diffusion-type passive samplers) as well as...
-
BTEX concentration levels in urban air in the area of the Tri-City agglomeration (Gdansk, Gdynia, Sopot), Poland
PublikacjaThe paper presents and discusses the results of atmospheric air quality research conducted in 2012 with reference to the level of BTEX compounds in the Tri-City agglomeration—Gdansk, Gdynia, and Sopot (northern Poland). At the stage of BTEX sampling from the ambient air, Radiello® diffusive passive samplers were applied. The annual time-weighted average concentrations for benzene, toluene, ethylbenzene, and xylenes (BTEX) in the...
-
Indoor air quality of everyday use spaces dedicated to specific purposes—a review
PublikacjaAccording to literature data, some of the main factors which significantly affect the quality of the indoor environment in residential households or apartments are human activities such as cooking, smoking, cleaning, and indoor exercising. The paper presents a literature overview related to air quality in everyday use spaces dedicated to specific purposes which are integral parts of residential buildings, such as kitchens, basements,...
-
Permeation passive sampling as a tool for the evaluation of indoor air quality
PublikacjaOkreślono stężenie średnie ważone w czasie wybranych lotnych związków organicznych w powietrzu ośmiu pomieszczeniach mieszkalnych na terenie miasta Gdańska. Do pobierania próbek analitów z powietrza wewnętrznego zastosowano permeacyjny dozymetr pasywny typu pudełkowego oraz technikę dynamiczną (urządzenie przepływowe z rurką sorpcyjną). Porównano wyniki uzyskane w wyniku zastosowania w/w technik pobierania próbek analitów.
wyświetlono 2562 razy