Speed sensorless ac drive with inverter output filter and fault detection using load torque signal - Publikacja - MOST Wiedzy

Wyszukiwarka

Speed sensorless ac drive with inverter output filter and fault detection using load torque signal

Abstrakt

In this paper, a sensorless induction motor (IM) drive using speed observer system is presented. The system includes load torque computation for gear fault detection. Nonlinear control method is adopted for controlling the motor over a wide speed range. An LC filter for smoothing current and voltage waveforms is used at the output of the voltage inverter. The use of filter imposes more building of the used observer to avoid using additional current and voltage sensors. An analysis of the motor load torque makes it possible to detect existing problems in the load. The developed algorithm was verified by simulation and experiments for a 1.5 kW induction motor drive system.

Cytowania

  • 0

    CrossRef

  • 0

    Web of Science

  • 0

    Scopus

Informacje szczegółowe

Kategoria:
Aktywność konferencyjna
Typ:
publikacja w wydawnictwie zbiorowym recenzowanym (także w materiałach konferencyjnych)
Język:
angielski
Rok wydania:
2010
Opis bibliograficzny:
Guziński J., Abu-Rub H., Toliyat H.: Speed sensorless ac drive with inverter output filter and fault detection using load torque signal// Industrial Electronics (ISIE), 2010 IEEE International Symposium on./ : , 2010, s.3113-3118