Wyniki wyszukiwania dla: MV CABLE LINE - MOST Wiedzy

Wyszukiwarka

Wyniki wyszukiwania dla: MV CABLE LINE
Przykład wyników znalezionych w innych katalogach

Wyniki wyszukiwania dla: MV CABLE LINE

  • Cross-Bonding of MV Cable Lines for Energy Losses Decrease

    Publikacja

    - Acta Energetica - Rok 2019

    Currently, almost all medium voltage cable lines (MV) operate with the return wires earthed at both ends of the cable. Such a way of operation causes that during normal states of operation as well as during disturbances, e.g. short-circuits, in the return wires induce currents whose values mainly depend on the currents flowing in the phase wires. These currents in normal operating states are a source of additional energy losses...

    Pełny tekst do pobrania w portalu

  • Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines

    Publikacja

    - ENERGIES - Rok 2020

    Cable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...

    Pełny tekst do pobrania w portalu

  • Modelling of MV and HV Cable Lines

    Overhead and cable lines are fundamental elements of power systems. Participation of cable lines is smaller and their percentage decreases as voltage is increased. HV cable lines are often built with the use of cables which are composed of coaxial metallic sheaths. Such cables are also often used in MV networks. The sheath may operate in different confgurations. In the case of Polish MV network the sheaths are earthed at both ends....

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Attempt to a Video-Transmission Capability in MV Mine Cable Network Using BPL-PLC Technology

    Publikacja
    • G. Debita
    • P. Falkowski-Gilski
    • M. Habrych
    • B. Miedziński
    • G. Wiśniewski
    • P. Jedlikowski
    • B. Polnik

    - Rok 2020

    This article presents and discusses the attempt to transmit video content using the BPL-PLC (Broadband over Power Line - Power Line Communication) technology. It includes simulation results of a specially developed digital transmitter and receiver, dedicated to a given predefined 6 kV mining power cable. The effect of two different transmission modes (2-7 MHz and 3-7.5 MHz) and two types of coupling (capacitive-inductive and induction-inductive),...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Quality Evaluation of Voice Transmission Using BPL Communication System in MV Mine Cable Network

    Publikacja

    - Elektronika Ir Elektrotechnika - Rok 2019

    This article presents results of a quality evaluation study, considering voice transmission in a 6 kV medium voltage cable network using the BPL (Broadband over Power Line) communication system. The tests are carried out under real mining conditions for the selected power cable without voltage, earthed at both sides. Such a method of monitoring work conditions is of great importance, especially during a disaster. Power cables are...

    Pełny tekst do pobrania w portalu

  • Energy losses reduction in the medium voltage cable line – case study

    Publikacja

    - Rok 2019

    The paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Study of Soil Temperature and Moisture Changes in a Physical Model of an Underground Cable Line

    Publikacja

    - Rok 2023

    The ampacity of power cables is highly dependent on the thermal resistivity of the soil in which they are laid. The lower it is, the higher this ampacity. The thermal resistivity of the soil decreases as its moisture increases. Therefore, it is preferable that the soil around the cables has high moisture. Unfortunately, the heat generated in heavily loaded cables causes the migration of moisture from the surrounding soil, which...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Hybrid high-frequency-SiC and line-frequency-Si based PEBB for MV modular power converters

    Publikacja

    - Rok 2012

    Izolowane przekształtniki DC-DC o sterowanym kącie przesunięcia napięć strony pierwotnej i wtórnej są kluczowymi elementami współczesnych modułowych przekształtników energoelektronicznych średniego napięcia (SN). W porównaniu do konwencjonalnych przekształtników SN, przekształtniki modułowe z izolowanymi przetwornicami DC-DC nie wymagają izolacji w postaci wielkogabarytowych transformatorów o częstotliwości sieci. Zastosowanie...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Overheating of underground power cable line due to its partial exposition to solar radiation

    Publikacja

    - Rok 2019

    Current-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • A new approach to cross-bonding in medium voltage cable lines

    Publikacja

    The medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints...

    Pełny tekst do pobrania w portalu