  • Cross-Bonding of MV Cable Lines for Energy Losses Decrease

    Publikacja

    - Acta Energetica - Rok 2019

    Currently, almost all medium voltage cable lines (MV) operate with the return wires earthed at both ends of the cable. Such a way of operation causes that during normal states of operation as well as during disturbances, e.g. short-circuits, in the return wires induce currents whose values mainly depend on the currents flowing in the phase wires. These currents in normal operating states are a source of additional energy losses...

    Pełny tekst do pobrania w portalu

  • Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines

    Publikacja

    - ENERGIES - Rok 2020

    Cable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...

    Pełny tekst do pobrania w portalu

  • Modelling of MV and HV Cable Lines

    Overhead and cable lines are fundamental elements of power systems. Participation of cable lines is smaller and their percentage decreases as voltage is increased. HV cable lines are often built with the use of cables which are composed of coaxial metallic sheaths. Such cables are also often used in MV networks. The sheath may operate in different confgurations. In the case of Polish MV network the sheaths are earthed at both ends....

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Attempt to a Video-Transmission Capability in MV Mine Cable Network Using BPL-PLC Technology

    Publikacja
    • G. Debita
    • P. Falkowski-Gilski
    • M. Habrych
    • B. Miedziński
    • G. Wiśniewski
    • P. Jedlikowski
    • B. Polnik

    - Rok 2020

    This article presents and discusses the attempt to transmit video content using the BPL-PLC (Broadband over Power Line - Power Line Communication) technology. It includes simulation results of a specially developed digital transmitter and receiver, dedicated to a given predefined 6 kV mining power cable. The effect of two different transmission modes (2-7 MHz and 3-7.5 MHz) and two types of coupling (capacitive-inductive and induction-inductive),...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Quality Evaluation of Voice Transmission Using BPL Communication System in MV Mine Cable Network

    Publikacja

    - Elektronika Ir Elektrotechnika - Rok 2019

    This article presents results of a quality evaluation study, considering voice transmission in a 6 kV medium voltage cable network using the BPL (Broadband over Power Line) communication system. The tests are carried out under real mining conditions for the selected power cable without voltage, earthed at both sides. Such a method of monitoring work conditions is of great importance, especially during a disaster. Power cables are...

    Pełny tekst do pobrania w portalu

  • Energy losses reduction in the medium voltage cable line – case study

    Publikacja

    - Rok 2019

    The paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Hybrid high-frequency-SiC and line-frequency-Si based PEBB for MV modular power converters

    Publikacja

    - Rok 2012

    Izolowane przekształtniki DC-DC o sterowanym kącie przesunięcia napięć strony pierwotnej i wtórnej są kluczowymi elementami współczesnych modułowych przekształtników energoelektronicznych średniego napięcia (SN). W porównaniu do konwencjonalnych przekształtników SN, przekształtniki modułowe z izolowanymi przetwornicami DC-DC nie wymagają izolacji w postaci wielkogabarytowych transformatorów o częstotliwości sieci. Zastosowanie...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Overheating of underground power cable line due to its partial exposition to solar radiation

    Publikacja

    - Rok 2019

    Current-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • A new approach to cross-bonding in medium voltage cable lines

    Publikacja

    The medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints...

    Pełny tekst do pobrania w portalu

  • The low-frequency magnetic field emissions on-board of the vessel

    Dane Badawcze
    open access

    The data represents measurement results performed on board of the vessel. The acquired time-waveforms, corresponding to the instantaneous values of the magnetic field (MF) induction were acquired near the cable supplying the bow thruster motor. Data recording of the magnetic field density (MFD) emissions was carried out with a/d converters of the data...

  • Zastosowanie specjalnego uziemienia żył powrotnych w liniach kablowych SN

    Publikacja

    W artykule porównano metody uziemiania żył powrotnych kabli średniego napięcia. Głównym kryterium oceny poszczególnych rozwiązań było ograniczenie strat w przesyle energii elektrycznej oraz zapewnienie ochrony przeciwprzepięciowej osłon kabli. Na podstawie symulacji kabli zamodelowanych w programie CYMCAP i otrzymanych wyników obciążalności prądowej i strat w linii zaprezentowano metodę krzyżowania żył powrotnych (CB – cross-bonding...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Mechanical Strength of MV Ship-switchgear During Fault Arc

    Publikacja

    In the paper the analysis of pressure stressed in enclosure during fault arc inside switchgear is pre-sented as well. There is introduced the method based on determining stresses which are sum of tensile stresses (membrane) and deflection stresses. For tensile stresses nalysis the energy method, for unrestrainedly supported rectangular plate, was used. In the further part of the paper, the calculations and measurements results...

    Pełny tekst do pobrania w portalu

  • Szybkie uziemniki do ograniczania skutków zwarć łukowych w okrętowych rozdzielnicach SN

    Publikacja

    - Rok 2014

    W artykule scharakteryzowano moc i napięcie łuku, jak również przedstawiono model termodynamiczny służący do obliczania ciśnienia i temperatury gazów w otoczeniu łuku zwarciowego. Przedstawiono przykładowy układ elektrowni okrętowej i zasilania najważniejszych odbiorników na statku do przewozu gazu ziemnego w stanie ciekłym. Na podstawie parametrów prądnic i silników odbiorników zasilanych z rozdzielnicy głównej obliczono prądy...

  • Usługi on-line w kontekście mobilnym - jakościowe badanie obserwacyjne

    Artykuł przedstawia wyniki badania obserwacyjnego, majacego na celu zidentyfikowanie czynników kształtujących u użytkowników chęć skorzystania z usług on-line za pomocą urządzeń mobilnych takich jak smartfon, tablet lub laptop. Przeprowadzono badania obserwacyjne, w których użytkownicy (7 osób) przez 14 dni notowali swoją aktywność w zakresie korzystania z usług on-line z dostępnych urządzeń w powiązaniu z czynnikami uznawanymi...

    Pełny tekst do pobrania w portalu

  • Determination of non-steroidal anti-inflammatory drugs in natural waters using off-line and on-line SPE followed by LC coupled with DAD-MS

    Opisano dwie metody pozwalające na jednoczesne oznaczanie zawartości niesterydowych leków przeciwzapalnych (difluisal, diklofenak, naproksen, tolmetin, fenoprofen, ibuprofen) w próbkach wodnych. Próbki przygotowywano do analizy z użyciem techniki ekstrakcji do fazy stałej (off-line i on-line). Natomiast oznaczeń końcowych dokonano z użyciem LC-DAD-MS. Sprawdzono kilka różnych kolumienek ekstrakcyjnych i wybrano RP-18 jako najlepsze...

  • Elipsometric data analysis used in on-line metal passivation monitoring

    Wykorzystano technikę elipsometrii monochromatycznej do opisu on-line warstw tlenkowych, elektroosadzanych na miedzi. Elipsometria jest w stanie dostarczyć informacji odnośnie grubości i współczynników załamania światła układów warstwowych, jednakże wymagane w tym celu jest zbudowanie matematycznego modelu odwzorowującego stałe optyczne układu badanego. W powyższej pracy przedyskutowane zostały różne metody dopasowywania modelu...

  • Possibility of exact determination of thermal and flow degradation symptoms in on-line power objects diagnostics

    Publikacja

    - Rok 2006

    Przedyskutowano problem dokładności tworzenia symptomów degradacji dotyczących sprawności urządzeń składowych dużych obiektów energetycznych. W referacie zajęto się szczególnie metodami tworzenia wzorców sprawnej pracy w przypadku określania sprawności w układzie on-line i porównano ją z określeniem w systemie off-line. Do odtwarzania stanu referencyjnego zastosowano sieć neuronową statystyczną (SSN, ang. ANN) o nieskokowych funkcjach...

  • AC motor feeding cable consequences on EMC performance of ASD

    Publikacja

    - Rok 2013

    High level of conducted EMI emissions of adjustable speed drives (ASD) is one of the most difficult problems in contemporary applications. Many investigations are carried out in order to find more effective methods allowing to predict this emission at early stage of design, and therefore to predict adequate countermeasures. This paper deals with the method which allows to estimate by simulation the influence of motor feeding cable...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Management of MV/LV Transformer Replacement Based on AMI Platform

    Publikacja

    - Automatyka Elektryka Zakłócenia - Rok 2023

    The paper presents the extended possibilities of managing the selection and replacement of MV/LV transformers using the measurement data from the Advanced Metering Infrastructure (AMI) system. The analysis was conducted on samples of over 1900 transformers that operate in two different types of MV grids: rural and urban. The analysis has shown that there is a great potential in the field of optimizing the rated power of the transformers.

    Pełny tekst do pobrania w serwisie zewnętrznym

  • The effect of cable duct diameter on the ampacity of high-voltage power cables

    Publikacja

    The ampacity of power cables depends, among others, on the conditions of heat dissipation from the cable to the environment. Cables are usually laid directly in the ground, but in some sections, they may be placed in ducts, which adversely affects the ampacity of the cable line. The paper presents heat transfer phenomena for cables installed in pipe-type ducts filled with air. The effect of cable duct diameter on this ampacity...

    Pełny tekst do pobrania w portalu

  • Reference FEM model for SHM system of cable-stayed bridge in Rzeszów

    The paper presents the references model for structural health monitoring system (SHM) of cable-stayed bridge recently constructed in Rzeszów over Wisłok River. The SHM system is design to provide on-line information on the structure state and facilitate its maintenance procedures. The main feature of the SHM system is permanent observation of the dynamic behavior of the bridge with focus on cable vibrations. The paper discusses...

  • Heat Dissipation from the Power Cable in the Casing Pipe

    Publikacja

    - IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS - Rok 2024

    The current carrying capacity of a power cable determines its ability to carry a specific current and is related to the efficiency of dissipation of heat generated in the cable laid in a specific environment. The studies were conducted in order to determine how the characteristics of the medium around the cable affected its temperature, and thus the ability of the cable to transmit electricity. The experimentation in the lab and...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Experiment-Based Study of Heat Dissipation from the Power Cable in a Casing Pipe

    Publikacja

    - ENERGIES - Rok 2022

    The paper deals with the important challenges in terms of electricity transmission by means of underground cable lines. The power cable’s performance is characterized by an ampacity that represents its maximum electric current-carrying capacity. The ampacity of power cables depends on their ability to diffuse the heat generated by the current flow into the environment. In the performed research, the analysis of the efficiency of...

    Pełny tekst do pobrania w portalu

  • On-Line Partitioning for On-Line Scheduling with Resource Conflicts

    Within this paper, we consider the problem of on-line partitioning the sequence of jobs which are competing for non-sharable resources. As a result of partitioning we get the subsets of jobs that form separate instances of the on-line scheduling problem. The objective is to generate a partition into the minimum number of instances such that the response time of any job in each instance is bounded by a given constant. Our research...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Estimation of the Maximum Permissible PV Power to be Connected to the MV Grid

    Publikacja

    - Rok 2023

    In recent decades, a significant increase in the share of renewable energy sources in power grids at various voltage levels has been observed. A number of articles have been published highlighting emerging problems in low-voltage grids with a large share of prosumers and in medium- and high-voltage grids to which photovoltaic (PV) plants are connected. The article analyzes the medium-voltage grid in terms of the possibility of...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • The Laboratory Stand for the Evaluation of Heat Dissipation from the Power Cable in a Casing Pipe

    Publikacja

    - Rok 2022

    The current carrying capacity of a power cable determines its efficiency, which depends on its capability to dissipate heat produced inside the cable, as a result of current flow, into the surrounding. The studies were conducted to determine how the characteristics of the medium around the cable affected its temperature and, as a result, its ability to transport electricity. The experimentation in the lab and real measurements...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Dynamic Response of the Suspended on a Single Cable Footbridge

    Publikacja

    The article presents numerical simulations, dynamic in situ load tests and a structural health monitoring (SHM) system installed in a suspended on a single cable footbridge. Numerical simulations performed prior to construction indicated the possibility of structural dynamics problems, finally confirmed in the course of dynamic test loading. In the dynamic load course the bridge deck developed vibrations displaying accelerations...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Numerical crash analysis of the cable barrier

    Safety barriers are used to increase road safety. Their basic task is to prevent the errant vehicle from getting off the road in places which are potentially dangerous for vehicle passengers. Barriers, which are used on European roads, must fulfill the requirements of EN 1317 standards by passing appropriate crash tests. Because of their high cost, numerical simulations are increasingly used to evaluate the properties of safety...

  • Geoambiente On-line

    Czasopisma

    ISSN: 1679-9860

  • Bottom Line

    Czasopisma

    ISSN: 0888-045X , eISSN: 2054-1724

  • Ciceroniana On Line

    Czasopisma

    eISSN: 2532-5353

  • Power Electronics Building Blocks for implementing Smart MV/LV Distribution Transformers for Smart Grid

    Publikacja

    With an observed increase in the involvement of active consumers in activities aimed at improving energy efficiency and increasing interest in producing energy from renewable sources, there is a need for the development of new technologies enabling the distribution network operators to offer new services and functionalities. Smart MV/LV distribution transformers are characterized by a compact three-stage design, including an...

    Pełny tekst do pobrania w portalu

  • Cable-stayed bridges. Basic static schemes

    The paper presents an overview of shaping of cable-stayed bridges. Historical background, basic static sketches and overview of selected bridges are included. Selected natural solutions and interesting unrealized projects were presented. Basic ideas and most important principals are discussed. The examples and sketches were given an author's comment. Static diagrams of two pylon structures with three variants of the arrangement...

    Pełny tekst do pobrania w portalu

  • DETERMINATION OF ADDITIONAL TENSION IN TOWED STREAMER CABLE TRIGGERED BY COLLISION WITH UNDERWATER MOVING OBJECT

    Publikacja

    - Polish Maritime Research - Rok 2020

    The paper deals with issues connected with the behaviour of a streamer cable towed by a survey seismic vessel when the cable undergoes a strike triggered by collision with an underwater moving object. The consequences of such collisions may be both threat to the life of marine animals or damage to underwater units and large economic losses suffered by vessel owners. The risk of such collisions has increased over the last years...

    Pełny tekst do pobrania w portalu

  • Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid

    Publikacja

    One of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...

  • Application of Structural Control Systems for the Cables of Cable-Stayed Bridges: State-of-the-Art and State-of-the-Practice

    Publikacja

    - ARCHIVES OF COMPUTATIONAL METHODS IN ENGINEERING - Rok 2021

    Stay cables are one of the key elements of cable-stayed bridges and are characterized by lightweight, low inherent damping, and high flexibility. They are continuously subjected to small-to large-amplitude vibrations due to various types of dynamic loads that may, in the long term, cause fatigue and fracture problems for the cable system, and may eventually compromise the safety of cable-stayed bridges. Thus, several countermeasures...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Broadband Modeling of Motor Cable Impact on Common Mode Currents in VFD

    Publikacja

    - Rok 2011

    Examination of conducted EMI generation and propagation in AC motor drives fed by frequency converter requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. AC motor winding voltage transients and related common mode currents are significantly correlated with resonance effects occurring in converter's load circuits. Intensity levels of these phenomena depend...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • On-line ranking of split graphs

    A vertex ranking of a graph G is an assignment of positive integers (colors) to the vertices of G such that each path connecting two vertices of the same color contains a vertex of a higher color. Our main goal is to find a vertex ranking using as few colors as possible. Considering on-line algorithms for vertex ranking of split graphs, we prove that the worst case ratio of the number of colors used by any on-line ranking algorithm...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Determination of the Bending Properties of Wire Rope Used in Cable Barrier Systems

    Publikacja

    - Materials - Rok 2020

    This paper presents research on the bending properties of 3 × 7 19-mm wire rope commonly used in road cable barriers. A total of 19 experimental tests were conducted. In addition, two nonlinear 3D numerical models of the wire rope using beam and solid finite elements were developed. Based on these models, four numerical simulations were carried out. The numerical results were validated against the experimental ones and a very good...

    Pełny tekst do pobrania w portalu

  • Cerclage cable augmentation does not increase stability of the fixation of intertrochanteric fractures. A biomechanical study

    Publikacja

    - Orthopaedics & Traumatology-Surgery & Research - Rok 2021

    Background: Intertrochanteric fractures with a posteromedial intermediate fragment are unstable because of the loss of medial support. Additional fixation with a cerclage is used in subtrochanteric fractures, but not in intertrochanteric fractures. The aim of this biomechanical study is to evaluate whether cerclage fixation improves stability of intertrochanteric fractures. Hypothesis: Our hypothesis is that the cerclage fixation...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • On-line P-coloring of graphs

    For a given induced hereditary property P, a P-coloring of a graph G is an assignment of one color to each vertex such that the subgraphs induced by each of the color classes have property P. We consider the effectiveness of on-line P-coloring algorithms and give the generalizations and extensions of selected results known for on-line proper coloring algorithms. We prove a linear lower bound for the performance guarantee function...

    Pełny tekst do pobrania w portalu

  • Theoretical analysis of the cable-stayed bridge over brda river in Bydgoszcz

    Publikacja

    The topic of this article is the numerical analysis carried out for the cable-stayed tram (road) bridge over Brda river in Bydgoszcz. The goal of numerical studies was the verification of project assumptions and construction solutions elaborated by the autonomous team. The bridge calculations were conducted on three independent FEM models The internal forces and the elements effort under different loading schemes were examined....

  • The influence of position of the post or its absence on the performance of the cable barrier system

    Road safety barriers are used to increase safety in potentially dangerous places on the roads. They are designed and installed on the roads to prevent any vehicle from getting outside the travelled way or from entering the opposite lane of the road. Barriers, which are used on European roads, have to undergo full scale crash tests according to the EN 1317 standards. Nowadays as a supplement to real crash tests, numerical simulations...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Numerical studies on the influence of selected construction features and road conditions on the performance of road cable barriers

    Publikacja

    - Rok 2018

    Cable barriers are commonly used on Polish roads, including motorways and local roads. Their main elements are pre-stressed wire ropes, which are usually anchored at two ends in concrete blocks buried in the soil. In this work numerical studies concerning the influence of selected construction features and parameters of the vehicle motion on the performance of cable barriers were performed. Numerical simulations are a useful tool...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Shape and force control of cable structures with minimal actuators and actuation

    Publikacja

    - International Journal of Space Structures - Rok 2021

    Shape adjustment and stress control can be considered as one of the effective parameters in prestressed cable structures since such structures are widely constructed nowadays due to their characteristics. The assembly errors and applied loads hugely affect the cables’ nodal positions and stress due to their delicacy. The former could disturb the shape, which affects the appearance and the function of the structure. In contrast,...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Wpływ usług on-line na budowanie pozytywnych relacji i lojalności klienta

    W artykule omówiono wybrane problemy projektowe dotyczące współczesnych usług on-line w kontekście budowania trwałej lojalności klienta. Przedstawiono model warstwowego rozwoju usług on-line wraz z zaleceniami projektowymi zorientowanymi na budowanie i wzmacnianie lojalności klienta. Przedstawiono przykłady scenariuszy rozwoju usług e-zdrowia online. Przedstawiono możliwości dalszego rozwoju prezentowanego podejścia i plany dalszych...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Pylon foundation of a cable stayed bridge at the motorway ring road of Wrocław

    The largest bridge of the motorway ring road of Wroclaw is a cable stayed bridge over the Odra river near Rędzin. Due to hydrogeological conditions of the ground it was not convenient to use standard bored piles of high length. Instead shorter piles were applied with additional improvement by cement injections at the pile toes. This decision was possible by extending ground investigation program and application of numerical modeling...

    Pełny tekst do pobrania w portalu

  • On-line Search in Two-Dimensional Environment

    We consider the following on-line pursuit-evasion problem. A team of mobile agents called searchers starts at an arbitrary node of an unknown network. Their goal is to execute a search strategy that guarantees capturing a fast and invisible intruder regardless of its movements using as few searchers as possible. We require that the strategy is connected and monotone, that is, at each point of the execution the part of the graph...

    Pełny tekst do pobrania w portalu

  • Mikroekonomia nst msu_on-line

    Kursy Online
    • A. B. Mikulska

    Podstawy mikroekonomii dla msu 4. sem. - 2h zajęć prowadzi w formule on-line dr Aniela Mikulska.

  • Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System

    This paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...

    Pełny tekst do pobrania w serwisie zewnętrznym