Nie znaleźliśmy wyników w zadanych kryteriach!
Ale mamy wyniki w innych katalogach.Filtry
wszystkich: 394
Wyniki wyszukiwania dla: CRITICAL VELOCITY
-
Life tests of a rotary single-stage magnetic-fluid seal for shipbuilding applications
PublikacjaUse of the magnetic fluid seal technology in water is much more difficult technological problem in comparisonto gas or vacuum environment. Some seals constructed up to time been are designed as hybrid, two stagesealing structures with shields or mechanical seals used as protection measures to the magnetic fluid seal.Anyway, there is always problem with immediate contact between magnetic fluid and the environmentalliquid. In the...
-
The Magnetic Fluid Seals Research Results vs. Kelvin-Helmholtz (K-H) instability and Preliminary Conclusions
PublikacjaIn the article a magnetic-fluid seals durability research and the tests results are presented. The tests were made with three magnetic fluids using various magnets quantity in magnetic assemblies. If values obtained in the repeated test deviated by more than 10 % from results of the first test an additional control test was made for final characteristics. The characteristics are: critical pressure, critical motion velocity and...
-
Data points of structures of R1233zd(E) flowing in a circular minichannel at low, medium and high values of saturation pressure
Dane BadawczeDatabase present structures of two-phase flow of R1233zd(E) in 3 mm vertical channel. Database contains datapoints which contain information of reduced pressure (ratio of saturation pressure and critical pressure), quality and mass velocity. 4 two phase structures are distinguished: bubbly flow, slug flow, intermittent flow and annular flow.
-
Multi-stage magnetic-fluid seals for operating in water - life test procedure, test stand and research results
PublikacjaThe edge criteria for magnetic-fluid seals durability research are critical for the seal'stechnological usefulness. The magnetic fluid seal technology in water is much moredifficult technological problem in comparison to gas or vacuum environment. There isalways problem with immediate contact between magnetic fluid and the environmentaluninspected liquids. In the paper are presented ways of experiments definitions carried outwith...
-
Multi-stage magnetic-fluid seals for operating in water - life test procedure, test stand and research results. Part II Results of life tests of multi-stage magnetic - fluid seal operating in water
PublikacjaThe edge criteria for magnetic-fluid seals durability research were described in previous article [24] and now the tests results are presented. The tests were made with three magnetic fluids using various magnets quantity in magnetic assemblies. If values obtained in the repeated test deviated by more than 10 % from results of the first test an additional control test was made for final characteristics. The characteristics are:...
-
COMPUTER ANALYSIS OF HYDRAULIC CONDITIONS IN A SANITARY CHAMBER
PublikacjaThis paper presents analysis of hydraulic conditions of sewage flow down the slipway (ramp) in the collecting sanitary chamber connecting 3 collectors on the inlet: ⌀600, ⌀800 and ⌀1400 and one on the outlet ⌀1600 mm, with a maximum difference of elevation 5 m. The mathematical model has been made and hydraulic calculations were carried out in steady flow conditions. Then wastewater surface elevation, energy grade line elevation,...
-
Visual method for detecting critical damage in railway contact strips
PublikacjaEnsuring an uninterrupted supply of power in the electric traction is vital for the safety of this important transport system. For this purpose, monitoring and diagnostics of the technical condition of the vehicle's power supply elements are becoming increasingly common. This paper presents a new visual method for detecting contact strip damage, based on measurement and analysis of the movement of the overhead contact line (OCL)...
-
STUDY OF ARRAY OF MEMS INERTIAL MEASUREMENT UNITS UNDER QUASI-STATIONARY AND DYNAMIC CONDITIONS
PublikacjaA measurement system includes all components in a chain of hardware and software that leads from a measured variable to processed data. In that context, the type and quality of the sensors or measuring devices are critical to any measurement system. MEMS/IMU sensors lag behind leading technologies in this respect, but the MEMS/IMU performance rapidly changes while is relatively inexpensive. For this reason, the paper proposes...
-
Pressure drop and heat transfer during boiling and condensation at subcritical region
PublikacjaMost of the data presented in the literature relate to saturation temperatures in the range - 20°C to 40°C due to the application in refrigeration technology. There is necessity to extend databases to higher values of saturation temperature due to new applications such as Organic Rankine Cycle and high temperature heat pumps. Only few papers contain data for high reduced pressure for low boiling point liquids. This paper focus...
-
Hydrauliczna wiarygodność wyników pomiarów terenowych stosowanych do identyfikacji oporności hydraulicznej przewymiarowanych sieci wodociągowych
PublikacjaPublikacja zawiera zalecenia metodyczne dotyczące identyfikacji oporności hydraulicznej w przewymiarowanych sieciach wodociągowych na tle spotykanych nieprawidłowości. Krytycznie oceniono wyniki pomiarów terenowych, które zastosowano do tarowania komputerowych modeli przepływów (KMP) pomimo, że nie spełniały kryterium hydraulicznej wiarygodności. Ponadto zaproponowano spadek hydrauliczny jako obiektywny wskaźnik wiarygodności pomiarów,...