Filtry
wszystkich: 4054
wybranych: 595
-
Katalog
- Publikacje 3009 wyników po odfiltrowaniu
- Czasopisma 142 wyników po odfiltrowaniu
- Konferencje 16 wyników po odfiltrowaniu
- Osoby 195 wyników po odfiltrowaniu
- Projekty 3 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 81 wyników po odfiltrowaniu
- Dane Badawcze 607 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: FRICTION FORCE CONTROL
-
API 5L X65 steel - CMOD-force record in -10°C, across rolling direction
Dane BadawczeSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
AFM (atomic force microscopy) images of borophene flakes obtained during ball milling at different operating parameters
Dane BadawczeThis dataset contains atomic force microscopy (AFM) images of representative borophene flakes obtained during ball milling. The operational parameters of the ball-milling process included rotation speed (250, 450, and 650 rpm), time of ball-milling (1, 3, 6, and 12 h), and the mass loading of starting bulk boron (1, 2, 3 g).
-
Lack of control over work and organizational citizenship behavior: overwork climate as a suppressor variable
Dane BadawczeThis study investigates a suppressor effect in the relationship between lack of control over work and organizational citizenship behavior (OCB). Suppressor effects operate when the addition of a predictor (in our study it is an overwork climate) increases the predictive power of another variable (lack of control over work) in predicting an outcome variable...
-
EH36 steel for shipbuilding (plate thicnkness 50mm) - CMOD - force record, a0/W = 0.6
Dane BadawczeThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding (plate thicnkness 40 mm) - CMOD - force record, a0/W = 0.5
Dane BadawczeThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding (plate thicnkness 40 mm) - CMOD - force record, a0/W = 0.6
Dane BadawczeThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding (plate thicnkness 30 mm) - CMOD - force record, a0/W = 0.6
Dane BadawczeThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding (plate thicnkness 60 mm) - CMOD - force record, a0/W = 0.6
Dane BadawczeThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding (plate thicnkness 50 mm) - CMOD - force record, a0/W = 0.5
Dane BadawczeThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
EH36 steel for shipbuilding (plate thicnkness 30 mm) - CMOD - force record, a0/W = 0.5
Dane BadawczeThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
API 5L X65 steel - fracture documentation of CMOD-force test in -10°C, across rolling direction
Dane BadawczeSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - fracture documentation of CMOD-force test in -10°C, along rolling direction
Dane BadawczeSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
Dual drive control under SVPWM, experimental results
Dane BadawczeThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The analysis includes the behaviour of the drive system, examining the dynamic system response to speed and angle changes, and encompassing data...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K04
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K05
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K03
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K01
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - DISTILLED WATER. Specim. set K07
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DISTILLED WATER. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - DISTILLED WATER. Specim. set K06
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DISTILLED WATER. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - PARAFFIN OIL. Specim. set K08
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: PARAFFIN OIL. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig:...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - DISTILLED WATER. Specim. set K02
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DISTILLED WATER. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - PARAFFIN OIL. Specim. set K09
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: PARAFFIN OIL. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig:...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - DISTILLED WATER. Specim. set K06
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DISTILLED WATER. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.7, b=0.32) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.1, b=0.14) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.8, b=0.25) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.5, b=0.37) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.4, b=0.26) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.0, b=0.11) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...