Case Study NEB Atlas / part II - Autodesk Forma analysis / Pilestredet Park, Oslo, Norway.
Dane BadawczeThe data present the results of the work on the analysis of modern settlements. The goal of this part of the research was to analyze housing estates already in place in various European cities. Analyses were performed in real time using artificial intelligence, and responses were searched for sun hours, daylight potential, noise, wind, and microclimate....
-
Case Study NEB Atlas / part II - Autodesk Forma analysis / King’s Cross, London, UK.
Dane BadawczeThe data present the results of the work on the analysis of modern settlements. The goal of this part of the research was to analyze housing estates already in place in various European cities. Analyses were performed in real time using artificial intelligence, and responses were searched for sun hours, daylight potential, noise, wind, and microclimate....
-
Case Study NEB Atlas / part II - Autodesk Forma analysis / Oceanhamnen, Helsingborg, Sweden
Dane BadawczeThe data present the results of the work on the analysis of modern settlements. The goal of this part of the research was to analyze housing estates already in place in various European cities. Analyses were performed in real time using artificial intelligence, and responses were searched for sun hours, daylight potential, noise, wind, and microclimate....
-
Case Study NEB Atlas / part II - Autodesk Forma analysis / La Courrouze district in Rennes, France
Dane BadawczeThe data present the results of the work on the analysis of modern settlements. The goal of this part of the research was to analyze housing estates already in place in various European cities. Analyses were performed in real time using artificial intelligence, and responses were searched for sun hours, daylight potential, noise, wind, and microclimate....
-
Lack of control over work and organizational citizenship behavior: overwork climate as a suppressor variable
Dane BadawczeThis study investigates a suppressor effect in the relationship between lack of control over work and organizational citizenship behavior (OCB). Suppressor effects operate when the addition of a predictor (in our study it is an overwork climate) increases the predictive power of another variable (lack of control over work) in predicting an outcome variable...
-
Number of active credit cards issued to individual customers (2017)
Dane BadawczePolish banks serviced 6.04 million credit cards in 2017. This is a decrease by 121,000 year on year (comparing 2017 and 2016). The largest issuer of credit cards in the country is Bank PKO BP. In the third quarter of 2017, this institution had 847,000 credit cards. Bank Zachodni WBK is second (803,000) and CITI Handlowy is third (697,000).
-
Number of active HCE cards installed in mobile phones (2017)
Dane BadawczeHCE technology (Host Card Emulation), which enables contactless payments by phone in a similar way as in the case of a payment card. At the time of making the transaction, the phone is close to the terminal, practically the same as the payment card. This solution, like the others described previously, should be included in the elements of electronic...
-
Number of active debit cards issued to individual customers (2017)
Dane BadawczeAt the end of the fourth quarter of 2017, financial institutions (including non-banking ones, e.g. SKOK) serviced 25.8 million debit cards (excluding credit card data) of individual clients. This means an increase by 1.3 million cards compared to the same period in 2016. The largest number of cards was issued and serviced by Bank PKO BP - 6.81 million,...
-
Number of active users of the mobile banking application (only a mobile phone) - 2017
Dane BadawczeCustomers using mobile devices can use their bank account via the bank's website or a separate application. Such a solution allows for easier logging in (usually no customer number is required, but only a password) and a number of additional functions (from a more extensive interface to a larger number of possible operations - making a transfer, opening...
-
Dual drive control under SVPWM, experimental results
Dane BadawczeThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The analysis includes the behaviour of the drive system, examining the dynamic system response to speed and angle changes, and encompassing data...
-
Glutathione conjugation of the antitumor-active 1-nitroacridine derivatives compounds C-857 and C-1748 – the major role of glutathione S-transferase M1-1
Dane BadawczeObjectives: C-857 and C-1748 are antitumor-active agents, monomers of unsymmetrical bisacridine derivatives. The aim of this study was to analyze their glutathione (GSH) conjugation in vitro in the presence of glutathione S-transferase (GST) M1-1.
-
Vident-real: an intra-oral video dataset for multi-task learning
Dane BadawczeWe introduce Vident-real, a large dataset of 100 video sequences of intra-oral scenes from real conservative dental treatments performed at the Medical University of Gdańsk, Poland. The dataset can be used for multi-task learning methods including:
-
Experimental Study of the Influence of Noise Level on the Uncertainty Value in a Measurement System Containing an Analog-to-Digital Converter
Dane BadawczeFor newly developed measuring systems it is easy to estimate type B uncertainties based on the technical data of the measuring modules applied. However, it is difficult to estimate A type un-certainties due to the unknown type and level of interferences infiltrating into the measuring sys-tem. This is a particularly important problem for measurements...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.7, b=0.32) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.1, b=0.14) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.8, b=0.25) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.5, b=0.37) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.4, b=0.26) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.0, b=0.11) and a air blow gun from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Measurements of no-load and short-circuit parameters of power transformers with taps
Dane Badawcze1) The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E).