Electrical responses of nanostructured ZrS3 as field-effect transistor for nitrogen dioxide, ethanol, and acetone detection enhanced by visible light
Dane BadawczeSmall-area layers of nanostructured ZrS3 were fabricated and measured in the field-effect transistor configuration. Irradiation with visible light enabled generating photocurrent and increasing the sensitivity to selected ambient gases: nitrogen dioxide, ethanol, and acetone. The data set consists of electrical responses (current vs. voltage characteristics...
-
Light transmission measurement through the fluidized bed photoreactor
Dane BadawczeDataset contains light transmission measurements through the fluidized bed photoreactor. Two sources of light were used: UV-LEDs and UV fluorescent. Measurements were performed at different air flows: 0, 80, 160 and 240 ml/min. The detailed measurement and equipment data was described in measurment info.txt file.
-
Chromium Cluster Luminescence: Advancing Near‐Infrared Light‐Emitting Diode Design for Next‐Generation Broadband Compact Light Sources
Dane BadawczeIn modern technology devices, an energy-saving miniature near-infrared (NIR) light source plays a critical role in non-destructive, non-invasive sensing applications and further advancement of technology. This dataset reports the broadband NIR luminescence of Cr3+ clusters for designing phosphor-converted NIR light-emitting diodes as an alternative...
-
UAV Survey Images - orthophotomap - Gdynia Container Terminal Day Light- MP1
Dane BadawczeDataset description: Raw images from photogrammetric survey. Object: Parking place near by Gdynia Container Terminal - day light photosLocation: Gdynia, Pomerania, PolandDrone type: DJI Mavic Pro 1Flight plan: Single GridTarget Product: OrthophotoDate: 15.10.2020Direct georeferencing: yesMetadata data: yes/GPSGCP: Yes - Description and position includedGCP...
-
UAV Survey Images - orthophotomap - Gdynia Container Terminal Day Light- MP2
Dane BadawczeDataset description: Raw images from photogrammetric survey. Object: Parking place near by Gdynia Container Terminal - day light photosLocation: Gdynia, Pomerania, PolandDrone type: DJI Mavic Pro 2Flight plan: Single GridTarget Product: OrthophotoDate: 15.10.2020Direct georeferencing: yesMetadata data: yes/GPSGCP: Yes - Description and position includedGCP...
-
Electrical and noise responses of Graphene-Silicon Schottky diodes decorated with Au nanoparticles for light-enhanced sensing of organic gases
Dane BadawczeGraphene-Silicon Schottky junctions decorated with Au nanoparticles were used for light-enhanced detection of organic tetrahydrofuran and chloroform. Au nanoparticles exhibited localized surface plasmon resonance (LSPR) in the range of yellow light; thus yellow LED (wavelength of 592 nm) was utilized to induce the plasmonic effect, that increased the...
-
Electrical and noise responses of carbon nanotube networks enhanced by UV light for detection of organic gases (ethanol, acetone)
Dane BadawczeCarbon nanotube networks of different optical transparencies were investigated via resistance and 1/f noise measurements for detection of ethanol and acetone. The sensor resistive and noise responses were collected for dark and UV-assisted conditions, revealing the improvement in sensor sensitivity and limit of detection after applying UV light (275...
-
Electrical responses of nanoporous NiO films for light-activated nitrogen dioxide and acetone gas sensing
Dane BadawczeThe chemoresistive sensor response of nanoporous NiO films prepared by advanced gas deposition was investigated with and without simultaneous light irradiation, to detect nitrogen dioxide and acetone gases. The presented data show electrical responses presented as sensor resistance or relative changes in sensor resistance under selected environment...
-
Unraveling Luminescent Energy Transfer Pathways: Futuristic Approach of Miniature Shortwave Infrared Light-Emitting Diode Design
Dane BadawczePhosphor-converted shortwave infrared phosphor light-emitting diodes (pc-SWIR LEDs, 900–1700 nm) are promising next-generation portable light sources for spectroscopy, security, optical communication, and medical applications. A typical design strategy involves energy transfer from Cr3+ to Ni2+, and thus, energy transfer from Cr3+–Cr3+ pairs to Ni2+...
-
Runner bean (Phaseolus coccineus) histological cross section observations of stems, leaves, and roots using light microscope
Dane BadawczeThis data set contains images of root crown, root, stem, and leaf cross-sections of runner bean (Phaseolus coccineus). Runner bean seedlings (3-5 cm) were planted on soil amended with poultry (chicken) manure biochars pyrolized at various temperatures (400, 500, and 600 C degrees). Three different poultry manure biochar materials (450, 500, and 600°C)...
-
Electrical and noise responses of carbon nanotube networks enhanced by UV light for nitrogen dioxide sensing
Dane BadawczeNetworks consisting of randomly oriented carbon nanotubes (CNN) were investigated toward nitrogen dioxide detection by means of electrical and low-frequency noise measurements. UV-activation of CNN layers improved gas sensitivity and reduced the limit of detection, especially by employing 275 nm-LED. This data set includes DC resistance measurements...
-
Electrical and noise responses of graphene back-gated field-effect transistors enhanced by UV light for organic vapors sensing
Dane BadawczeBack-gated field-effect transistors with graphene channels (GFETs) were investigated toward organic vapors sensing. Two methods were used for sensing experiments including DC characteristics measurements and fluctuation-enhanced sensing by low-frequency noise studies. The data set consists of raw and modified data on GFET responses to acetonitrile,...
-
Optical transmission of the Niobium thin films
Dane BadawczeNiobium thin films with a thickness of 200nm were deposited n a Corning glass substrate by magnetron sputtering method. The optical transmission spectra in a visible light range were.recorded. Investigations showed a good optical transmission thru the layers for each samples, annealed at various temperatures. For measurements samples annealed at 500,...
-
LDRAW based renders of LEGO bricks moving on a conveyor belt
Dane BadawczeThe set contains renders of 5237 LEGO bricks moving on a white conveyor belt. The images were prepared for training neural network for recognition of LEGO bricks. For each brick starting position, alignment and color was selected (simulating the brick falling down on the conveyour belt) and than 10 images was created while the brick was moved across...
-
Plasmon resonance in a TiO2-Au NPs structures
Dane BadawczeInvestigated structures were deposited on a pre cleaned Corning 1737 glass substrates, which provided flat optical transmission characteristics and high transmission coefficient in a visible light range. Plasmonic nanostructures were formed as a result of thermal annealing. For gold films with thickness of 2.8 nm depiction a table-top dc magnetron sputtering...
-
LDRAW based renders of LEGO bricks moving on a conveyor belt with extracted models
Dane BadawczeThe set contains renders of LEGO bricks moving on a white conveyor belt. The images were prepared for training neural network for recognition of LEGO bricks. For each brick starting position, alignment and color was selected (simulating the brick falling down on the conveyour belt) and than 10 images was created while the brick was moved across the...
-
A study of nighttime vehicle detection algorithms
Dane BadawczeThis dataset is from my master's thesis "A study of nighttime vehicle detection algorithms". It contains both raw data and preprocessed dataset ready to use. In the pictures below you can see how images were annotated.
-
The XRD diffraction pattern of interdiffusion test in the CLO-NiO-YSZ system (30wt.%YSZ)
Dane BadawczeThe dataset includes the XRD pure diffraction pattern of the interdiffusion system consisting of CLO (Ce0.8La0.2O2), NiO and 8YSZ (8mol.% Y2O3 stabilized ZrO2). The mixture contains equal amounts of CLO and NiO as well as 30wt.% 8YSZ. Samples were sintered at 1400 oC. The reaction between CLO and YSZ is visible.
-
The XRD diffraction pattern of interdiffusion test in the CLO-NiO-YSZ system (10wt.%YSZ)
Dane BadawczeThe dataset includes the XRD pure diffraction pattern of the interdiffusion system consisting of CLO (Ce0.8La0.2O2), NiO and 8YSZ (8mol.% Y2O3 stabilized ZrO2). The mixture contains equal amounts of CLO and NiO as well as 10wt.% 8YSZ. Samples were sintered at 1400 oC. The reaction between CLO and YSZ is visible.
-
The XRD diffraction pattern of interdiffusion test in the CLO-NiO-YSZ system (20wt.%YSZ)
Dane BadawczeThe dataset includes the XRD pure diffraction pattern of the interdiffusion system consisting of CLO (Ce0.8La0.2O2), NiO and 8YSZ (8mol.% Y2O3 stabilized ZrO2). The mixture contains equal amounts of CLO and NiO as well as 20wt.% 8YSZ. Samples were sintered at 1400 oC. The reaction between CLO and YSZ is visible.