Filtry
wszystkich: 1348
wybranych: 1117
-
Katalog
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: hybrid constructed wetland
-
Evaluation of respiration capacity of VF in hybrid constructed wetland systems.
PublikacjaThree VF-beds operating in hybrid constructed wetlands in configuration HF-VF-HF were analysed. These hybrid constructed wetlands provide the II stage biological treatment. They are located in Pommerania voivodship, in Sarbsk, Wiklino and Wieszyno, and their capacities are 29.5, 14.2 and 21.6 m3/d, respectively. The article focuses on performance and operation of VF-CW plants during one year. Based on removal of organic matter...
-
Using terrestrial laser scanning in inventorying of a hybrid constructed wetland system
PublikacjaThe goal of this paper was to evaluate the possibility of using terrestrial laser scanning (TLS) for inventorying of a hybrid constructed wetland (CW) wastewater treatment plant. The object under study was a turtle-shaped system built in 2015 in Eastern Poland. Its main purpose is the treatment of wastewater from theMuseumand Education Centre of Polesie National Park. The study showed that the CW system had been built in compliance...
-
The Concept of Construction of Hybrid Constructed Wetland for Wastewater Treatment in Roztocze National Park
PublikacjaRoztocze National Park (RNP) is one of 23 national parks in Poland. It was created in 1974 both to protect the natural and cultural heritage as well as to share the park area for science, education and tourism. In caring for the environment, the park removed asbestos coverage, performs thermo-modernization using renewable energy sources by the installation of solar panels and photovoltaic cells on the roofs of buildings, and pellet...
-
The efficiency and reliability of pollutant removal in a hybrid constructed wetland with giant miscanthus and Jerusalem artichoke in Poland
PublikacjaIn this paper, we analysed the pollutant removal efficiency and reliability of a vertical and horizontal flow hybrid constructed wetland (CW) planted with giant miscanthus and Jerusalem artichoke. The wastewater treatment plant, located in south-eastern Poland, treated domestic sewage at an average flow rate of 1.2m3·d−1. The tests were carried out during. 5-years of operation of the sewage treatment plant (2011–2016). During this...
-
Assessment of the technological reliability of a hybrid constructed wetland for wastewater treatment in a mountain eco-tourist farm in Poland
PublikacjaThe aim of the present study was to assess the technological reliability of a domestic hybrid wastewater treatment installation consisting of a classic three-chambered (volume 6 m3) septic tank, a vertical flow trickling bed filled with granules of a calcinated clay material (KERAMZYT), a special wetland bed constructed on a slope, and a permeable pond used as a receiver. The test treatment plant was located at a mountain eco-tourist...
-
Experience of hybrid constructed wetlands operation in Gdansk region
PublikacjaThe investigation were carried out at five local hybrid constructed wetlands (HCWs), which secured biological treatment of domestic wastewater generated from 15 to 600 pe. Based on over two years monitoring it was indicated that HCWs ensured very effective removal of organic matter from 74.9 to 95.5 COD % in wild range of loadings (1.5 - 17.0g COD/ m3day). Efficiency of total nitrogen removal varied significantly from 23.4 two...
-
Pathways of nitrogen compounds depletion in hybrid constructed wetlands
PublikacjaHybrid Constructed Wetlands are composed of two or more filters with mixed flow direction of sewage. Apparently in the HCWS the benefits of both types of bed are merged, resulting in better effluent quality (organic and nitrogen componds removal). Such heterogeneous environment creates possibilities for different ways of nitrogen "disappearing". The objective of the present study was to compare the removal of nitrogen with accompanying...
-
Influence of configurations of the beds on contaminations removal in hybrid constructed wetlands.
PublikacjaThree hybrid constructed wetlands in configuration HF-VF-HF in Poland and one with another configuration VF-HF-Pond in Gremany were analysed. These hybrid constructed wetlands provide the second stage biological treatment. They are located in Pommerania region, in Sarbsk, Wiklino and Wieszyno, and their capacities are 29.7, 18.6 and 24.5 m3/day, respectively. The analysed system in Germany in Waizenfeld (Gemeinde Pommelsbrunn,...
-
Effectiveness of pollutants removal in hybrid constructed wetlands – different configurations case study
PublikacjaIn recent years, an increase in interest in hybrid constructed wetland systems (HCWs) has been observed. The aim of the paper is to compare different HCW configurations in terms of mass removal rates and efficiency of pollutants removal. Analysed data have been collected at multistage constructed wetlands in Poland, which are composed by at least two beds: horizontal subsurface flow (SSHF) and vertical subsurface flow (SSVF). The...
-
Dependence between quality and removal effectiveness of organic matter in hybrid constructed wetlands
PublikacjaW procesie oczyszczania ścieków w Vertical Flow Constructed Wetland (VF-CW) jednym z czynników jest dopływ tlenu. Niewystarczający dopływ tlenu do złoża może być przyczyną braku efektywności usuwania zanieczyszczeń, a więc wskazywać na niewłaściwą eksploatację obiektu.Obiekty badań stanowiły złoża pionowe stanowiące jeden z elementów biologicznego oczyszczania dwóch hybrydowych systemów hydrofitowych zlokalizowanych w Wieszynie...
-
Hybrid constructed wetlands for the National Parks in Poland - a case study, requirements, dimensioning, preliminary results
PublikacjaWater and wastewater management, especially in rural areas, greatly affects loads of nutrients discharged to the Baltic Sea. In Poland, this management is unbalanced because of the dispersed development and in many locations con struction of sewerage system is uneconomic or even impossible. For this reason, a significant part of sewage from single-family houses in rural areas must be discharged into domestic sewage systems. The...
-
The removal of biogenic compounds and suspended solids in a constructed wetland system
PublikacjaW celu ochrony ujęcia powierzchniowego wody pitnej dla m. Gdańska w 1997 roku został wybudowany obiekt hydrofitowy na cieku spływającym ze wsi Bielkowo. System hydrofitowy jest zbiornikiem retencyjnym złożonym z dwóch części: - część ''mokra'' tzn. stale wypełniona wodą stanowiąca system grobli z wewnętrznym drenażem, która miała pełnić rolę oczyszczających złóż korzeniowych, - część ''sucha'' wypełniająca się wodą okresowo i przeznaczona...
-
Operational problems of constructed wetland for landfill leachates treatment: case study
PublikacjaIn the paper the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and evaluation of a wetland system designed for treatment of the leachate are discussed.The research has been conducted during the 5 years period. The constructed wetland for leachate treatment, consisting of 2 horizontal subsurface flow reed beds, working in parallel was built in 2001. In the period 2005-06 it underwent...
-
OPERATIONAL PROBLEMS OF CONSTRUCTED WETLAND FOR LANDFILL LEACHATE TREATMENT: CASE STUDY
PublikacjaThe present paper discusses the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and the evaluation of a wetland system designed for treatment of the leachate. The research has been conducted during a 5-year period. The constructed wetland for leachate treatment was built in 2001; it consists of 2 horizontal subsurface flow reed beds, working in parallel. In the period 2005–2006...
-
Removal and speciation of heavy metals in the constructed wetland treating landfill leachate
PublikacjaThe results of heavy metals removal and speciation of metals at two treatment wetlands receiving landfill are discussed. The first TW is a surface flow facility consisting of 10 ponds. The next TW is a newly constructed pilot-scale facility consisting of three beds with alternately vertical and horizontal sub-surface flow. The metals concentrations were analysed in leachate(both TWs) and bottom sediments (surface flow TW). Seasonal...
-
Constructed wetland systems for aerial runoff treatment in the Gulf of Gdansk region
PublikacjaW artykule przywołano przykłady udanych wdrożeń obiektów hydrofitowych oczyszczania spływów obszarowych na terenie aglomeracji trójmiejskiej. Zespół obiektów hydrofitowych wybudowany w ZOO w Oliwie wykazał szczególnie wysoką skuteczność usuwania związków azotu. Obiekt hydrofitowy na Potoku Swelina spowodował znaczną poprawę jakości wód Potoku, a co za tym idzie i czystości kąpieliska w rejonie Kamiennego Potoku w Sopocie. Podjęte...
-
A fast start-up of the organotrophic anammox process inoculated with constructed wetland sediment
PublikacjaOrganotrophic anaerobic ammonium oxidation (anammox) bacteria can utilize small volatile fatty acids with nitrate as electron acceptors with less energy consumption and no biomass production. To achieve a faster and stable start-up of organotrophic anammox process, in this study, the growth of organotrophic anammox bacteria seeded from hybrid constructed wetland (CW) sediment under different TOC/TN ratios and different chloramphenicol...
-
Assessment of metal removal in a surface flow constructed wetland treating landfill leachate
PublikacjaThe study concerns heavy metal retention and transformation processes in a free water surface constructed wetland treating landfill leachate in a temperate climate. The total effectiveness of heavy metals removal in the analyzed CW was evaluated basing on heavy metals inflow and outflow concentrations. The concentrations of eight heavy metals (Fe, Mn, Zn, Pb, Ni, Cu, Cr, Cd) in landfill leachate (LL) and sediments were measured....
-
Removal of organic matter and nitrogen in an horizontalsubsurface flow (HSSF) constructed wetland undertransient loads
PublikacjaA monitoring campaign in a horizontal subsurface flow constructed wetland under the influence of transient loads of flow-rate, organic matter, nitrogen and suspended solids showed an irregular removal of COD and TSS and lower both removal efficiencies and mass removal rates than the ones observed in other studies for similar operating conditions. This circumstance is associated to the presence of large amount of particulate organic...
-
Temperature Impact of Nitrogen Transformation in Technological System: Vertical Flow Constructed Wetland and Polishing Pond
PublikacjaThe article describes the results of the research, purpose of which was to evaluate influence of the temperature on the effectiveness of nitrification and denitrification in the sewage treatment system consisting of vertical flow constructed wetland and polishing pond. During the analysed period, the efficiency of removing total nitrogen was low and amounted to 12.7%. In the polishing pond in the summer period, content of total...