Filtry
wszystkich: 1963
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: detection
-
The Transmission Protocol of Sensor Ad Hoc Networks
PublikacjaThis paper presents a secure protocol for a radio Ad Hoc sensor network. This network uses the TDMA multiple access method. The transmission rate on the radio channel is 57.6 kbps. The paper presents the construction of frames, types of packets and procedures for the authentication, assignment of time slots available to the node, releasing assigned slots and slots assignment conflict detection.
-
Gas chromatography-olfactometry (GC-O), electronic noses (e-noses) and electronic tongues (e-tongues) for in vivo food flavour measurement
PublikacjaThe capter revies two types of artificial olfaction instrumentation, i.e. gas-chromatography-olfactometry (GC-O) and chemical sensor technologies (electronic nose and tongue), combined with multivariate data processing methods as promising approaches for rapid analysis of food. The chapter also includes examples of specific applications for the detection of food flavour and volatile components.
-
Deep slot effect in the squirrel-cage induction motors with scalar (V/F) control
PublikacjaQualitative characteristics of the electrical drive considerably depend on identification accuracy of math model parameters. In particular, it is depend on detection accuracy of stator active resistance r1 that is used in calculation of flux linkages, rotary speed in sensorless control systems. Paper provides analysis of influence of stator deep slot effect to stator active resistance value
-
POSSIBILITY OF ASSESSMENT OF OPERATION OF SLIDING BEARINGS IN PISTON-CRANK MECHANISMS OF DIESEL ENGINES WITH REGARD TO LOAD AND TIME OF CORRECT WORK OF THE BEARINGS BY APPLYING ACOUSTIC EMISSION AS A DIAGNOSTIC SIGNAL
PublikacjaAbstract: The paper presents a possibility of determining (assessing) operation of sliding bearings with multilayer bushings in crank-piston mechanisms of diesel engines. Properties of load and wear, particularly fatigue and abrasive, are characterized in general. Acoustic emission as a diagnostic signal was proved to be useful for detection of the wear of sliding and barrier layers. Results of measurements of acoustic emission...
-
Use of Neural Networks in Diagnostics of Rolling-Element Bearing of the Induction Motor
PublikacjaBearing defect is statistically the most frequent cause of an induction motor fault. The research described in the paper utilized the phenomenon of the current change in the induction motor with bearing defect. Methods based on the analysis of the supplying current are particularly useful when it is impossible to install diagnostic devices directly on the motor. The presented method of rolling-element bearing diagnostics used indirect...
-
Raman Spectra Measurements for Chemical Identifications - Aspect of Uncertainty Sources and Reduction of Their Effects
PublikacjaRaman spectrometers enable fast and non-contact identification of examined chemicals. These devices measure Raman spectra and compare with the spectra database to identify unknown and often illicit chemicals (e.g. drugs, explosives) usually without any sample preparation. Raman spectra measurements are a challenge due to noise and interferences present outside the laboratories (field applications). The design of a portable Raman...
-
Video Semantic Analysis Framework based on Run-time Production Rules - Towards Cognitive Vision
PublikacjaThis paper proposes a service-oriented architecture for video analysis which separates object detection from event recognition. Our aim is to introduce new tools to be considered in the pathway towards Cognitive Vision as a support for classical Computer Vision techniques that have been broadly used by the scientific community. In the article, we particularly focus in solving some of the reported scalability issues found in current...
-
A magnetic imprinted polymer nano-adsorbent with embedded quantum dots and mesoporous carbon for the microextraction of triazine herbicides
PublikacjaA magnetic molecularly imprinted polymer (MMIP) adsorbent incorporating amino-functionalized magnetite nanoparticles, nitrogen-doped graphene quantum dots and mesoporous carbon (MIP@MPC@NGQDs@ Fe3O4–NH2) was fabricated to extract triazine herbicides from fruit juice. The embedded magnetite nanoparticles simplified the isolation of the adsorbent from the sample solution. The N-GQDs and MPC enhanced adsorption by affinity binding...
-
INVESTIGATION OF THE LOMBARD EFFECT BASED ON A MACHINE LEARNING APPROACH
PublikacjaThe Lombard effect is an involuntary increase in the speaker’s pitch, intensity, and duration in the presence of noise. It makes it possible to communicate in noisy environments more effectively. This study aims to investigate an efficient method for detecting the Lombard effect in uttered speech. The influence of interfering noise, room type, and the gender of the person on the detection process is examined. First, acoustic parameters...
-
Optimization of a Fabric Phase Sorptive Extraction protocol for the isolation of six bisphenols from juice pouches to be analysed by high performance liquid chromatography coupled with diode array detector
PublikacjaFabric Phase Sorptive Extraction (FPSE) combined with high pressure liquid chromatography using to diode array detection (HPLC-DAD) was applied for the simultaneous determination of bisphenols (BPA, BPB, BPC, BPE, BPF, BPS) in juice pouches. The FPSE procedure was optimized with regards to the critical parameters that affect the performance of the method including the selection of the FPSE membrane type and size, adsorption time,...
-
Chromium‑based metal organic framework for pipette tip micro‑solid phase extraction: an effective approach for determination of methyl and propyl parabens in wastewater and shampoo samples
PublikacjaAbstract Background A chromium-based metal organic framework was synthesized and employed as an efficient sorbent for pipette tip micro-solid phase extraction and preconcentration of parabens from wastewater and shampoo samples up to sub-ppb level before their spectrophotometric analysis. Results Factors affecting preconcentration including volume and type of solvent, amount of sorbent, number of extraction, and volume and pH of...
-
Dekodowanie kodów iterowanych z użyciem sieci neuronowej
PublikacjaNadmiarowe kody iterowane są jedną z prostych metod pozyskiwania długich kodów korekcyjnych zapewniających dużą ochronę przed błędami. Jednocześnie, chociaż ich podstawowy iteracyjny dekoder jest prosty koncepcyjnie oraz łatwy w implementacji, to nie jest on rozwiązaniem optymalnym. Poszukując alternatywnych rozwiązań zaproponowano, przedstawioną w pracy, strukturę dekodera tego typu kodów wspomaganą przez sieci neuronowe. Zaproponowane...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-MAG1L
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen AMA1-MIC3-ROP1
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA7
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-AMA1F
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-P35
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA9
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA6
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-MIC1L
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA1
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-LDH2
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-MIC3
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-ROP1
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-AMA1
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA5
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA2
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Short-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Bioterrorism — characteristics and possibilities of prevention
PublikacjaIn the paper bioterrorist threats have been presented. Historical background and possible methods of attacks have been described. The most dangerous pathogens and disease entities have been classified. Selected methods of detection and identification of biological weapon have been presented. The wireless system for threats monitoring — developed at Gdansk University of Technology — has been described.
-
The secure transmission protocol of sensor Ad Hoc network
PublikacjaThe paper presents a secure protocol of radio Ad Hoc sensor network. This network operates based on TDMA multiple access method. Transmission rate on the radio channel is 57.6 kbps. The paper presents the construction of frames, types of packets and procedures for the authentication, assignment of time slots available to the node, releasing assigned slots and slots assignment conflict detection.
-
Long-term measurement of physiological parameters - patient 7 (serie 2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 6)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 14)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Short-term measurement of physiological parameters - child (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurement of physiological parameters were performed on the healthy...
-
Long-term measurement of physiological parameters - patient 7 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 14)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 7 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 10)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 11)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 7 (serie 9)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (1 hour) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 21)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 7)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (1.5 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 5 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 18)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 6)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2.5 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 7 (serie 3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (2 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 13)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 7 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...