Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublikacjaThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Expert opinion on the effectiveness of protection against electric shock in case of fault in an installation for electric vehicles charging
PublikacjaThe opinion concerns the use of residual current devices for protection against electric shock by automatic disconnection of supply in a Norwegian installation intended for charging of electric vehicles.
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublikacjaThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Service-based Resilience via Shared Protection in Mission-critical Embedded Networks
PublikacjaMission-critical networks, which for example can be found in autonomous cars and avionics, are complex systems with a multitude of interconnected embedded nodes and various service demands. Their resilience against failures and attacks is a crucial property and has to be already considered in their design phase. In this paper, we introduce a novel approach for optimal joint service allocation and routing, leveraging virtualized...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublikacjaEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublikacjaIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublikacjaMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublikacjaVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Residual Current Devices: Selection, Operation, and Testing
PublikacjaIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
Resonance problems in UHV transmission lines
PublikacjaThe paper presents resonance phenomena observed in 400 kV transmission lines in the Polish power system. Two events are analysed, when shunt reactors used for reactive power compensation, caused overvoltages and overcurrent protection tripping as a result of resonance. An oscillographic fault recordings from protection devices are compared to time domain simulation results. The obtained simulation results match fault recordings,...
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Tripping limitations of residual current devices in photovoltaic installations
PublikacjaIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublikacjaLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Behavior of residual current devices at earth fault currents with DC component
PublikacjaLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Electric shock hazard in circuits with variable-speed drives
PublikacjaThe conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50/60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives...
-
Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
PublikacjaThe paper dealt with the issue of breakdowns detection of isolated hanging wires on the medium-voltage transmission. The main aim of article is to describe the function of created breakdowns detector and evaluation its. The breakdowns detector is created based in indicators of faults such as touch between tree limbs and insulated wire, touch tree limbs with several phases or fall insulated wire on the ground. Breakdowns detector...
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublikacjaThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Residual current devices in electric vehicles charging installations
PublikacjaThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...
-
Performance analysis of power swing blocking feature in ABB 670 series impedance relays
PublikacjaThis paper presents test results of a distance protection’s PSD power swing detection feature in ABB 670 series relays. A RED670 relay was tested, which is part of the hydroelectric set protection in Żarnowiec Pumped Storage Plant. The power swing blocking feature’s performance was analysed on the basis of the results of object tests made with an Omicron digital tester. Also presented are simulation results that illustrate the...
-
Fault detection in the marine engine using a support vector data description method
PublikacjaFast detection and correct diagnosis of any engine condition changes are essential elements of safety andenvironmental protection. Many diagnostic algorithms significantly improve the detection of malfunctions.Studies on diagnostic methods are rarely reported and even less implemented in the marine engine industry.To fill this gap, this paper presents the Support Vector Data Description (SVDD) method as applied to thefault detection...
-
Low-frequency tripping characteristics of residual current devices
PublikacjaFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublikacjaThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Effect of the let-through energy of overcurrent protective devices on the temperature of conductors during short-circuits
PublikacjaThe scope of the verification of low-voltage systems covers the earth fault loop impedance measurement. This measurement is usually performed with the use of low-value current meters, which force a current many times lower than the one occurring during a real short-circuit. Therefore, the international standard recommends consideration of the increase of resistance of conductors with the increase of temperature, which may occur...
-
Uziemienia w zespołach elektrowni wiatrowych
PublikacjaW pracy jest omawiana problematyka budowy systemów uziemień na farmach elektrowni wiatrowych. Uziemienia poszczególnych elektrowni są wykorzystywane jako elementy systemu ochrony odgromowej oraz układu ochrony od porażeń otoczenia elektrowni wiatrowej. Farmy elektrowni są często umieszczane na gruntach o wysokiej rezystywności, co utrudnia realizację skutecznych systemów uziemień elektrowni. Trudność może napotykać zwłaszcza wykonanie...
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublikacjaThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublikacjaElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
Tripping of F-type RCDs for high-frequency residual currents
PublikacjaResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs are...
-
Tripping of F-type RCDs for High-Frequency Residual Currents
PublikacjaResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs...
-
Trends in Locally Balanced Energy Systems without the Use of Fossil Fuels: A Review
PublikacjaIn recent years, the idea of the operation of energy systems (power systems, heating systems) has changed significantly. This paper is an overview of locally balanced energy systems without the use of fossil fuels. The paper justifies the concept of local energy balancing in a new energy system that does not use fossil fuels (coal, natural gas, and crude oil), based on European Union guidelines and formal documents as well as the...
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublikacjaW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...
-
Kazimierz Darowicki prof. dr hab. inż.
OsobyStudia wyższe ukończyłem w czerwcu 1981 roku po zdaniu egzaminu dyplomowego i obronie pracy magisterskiej. Opiekunem pracy magisterskiej był dr hab. inż. Tadeusz Szauer. W roku 1991, 27 listopada uzyskałem stopień naukowy broniąc pracę doktorską zatytułowaną „Symulacyjna i korelacyjna analiza widm immitancyjnych inhibitowanej reakcji elektrodowej”. Promotorem pracy był prof. dr hab. inż. Józef Kubicki (Wydział Chemiczny...
-
Fermi-liquid behavior of binary intermetallic compounds Y3 M (M = Co, Ni, Rh, Pd, Ir, Pt)
PublikacjaA series of polycrystalline samples of Y3 M (M = Co, Ni, Rh, Pd, Ir, Pt), intermetallic binary compounds were synthesized by the arc-melting method. Powder x-ray diffraction (pXRD) confirmed the orthorhombic cementite-type crystal structure and allowed for the estimation of the lattice parameters. Physical properties were investigated by means of electrical resistivity and heat capacity measurements between 1.9 K and 300 K. All...