Wyniki wyszukiwania dla: INDOOR AIR
-
Co-simulation strategy of transient CFD and heat transfer in building thermal envelope based on calibrated heat transfer coefficients
PublikacjaThe paper presents a strategy to develop a fully transient numerical model of a heat transfer in building, using a transient CFD model of indoor air and a thermal envelope model, running in a co-simulation. The strategy relies on the utilization of RANS with a high-Re turbulence model and a wall function, which enables to use a coarse computational mesh limiting the computational time. Since wall functions give invalid heat transfer...
-
Application of Passive Samplers in Monitoring of Organic Constituents of Air
PublikacjaThe principles of passive dosimetry, which has been known for over 100 years, are finding an ever increasing use in analytical practice and are being used as a convenient technique for isolation and enrichment of analytes from various environmental media. Due to its simplicity, a variety of designs, as well as the possibility of using a number of different final determination techniques, passive dosimetry has been applied in...
-
Natural ventilation performance of family building in cold climate during windy days
PublikacjaAdequately designed natural ventilation is the cheapest and easiest way to effectively remove indoor pollutants and keep the fresh air inside a building. A prediction of performance and effectiveness of ventilation in order to determine the design of a ventilation system can provide real and long term cost savings. The paper presents results of performance (air change rate ACH) and effectiveness (CO2 concentration in the breathing...
-
Natural ventilation performance of family building in cold climate during windless time
PublikacjaIn this paper, the field measurements results are presented on the stack ventilation effect. The paper presents the results of performance (air change rate ACH) natural ventilation for building with inlet gap measured for the transitional season (between heating and summer season). The measurements were performed during a windless time. The house was located in northern Poland, in a cold climate region. The measurement system...
-
Sick building syndrome due to molds
PublikacjaThe term Sick Building Syndrome (SBS) is a combination of ailments occurring in a specific building. Building occupants complain of symptoms such as headaches and dizziness, fainting, nausea, irritation of the mucosal membranes, skin irritation and other nonspecific hypersensitivity reactions.One of the SBS causes can be molds, which are ubiquitous in the air (over 400 species). It is estimated that 30% of the health problems (related...
-
Monoterpenes emissions from different samples of wood-based materials – laminated chipboards and medium-density fiberboards (MDF)
PublikacjaThe paper presents the results of studies on emission rates of monoterpenes, carried out with the use of a new type of device - Markes’ Micro-Chamber/Thermal Extractor™ (μ-CTE250). Subject of studies were different types of wood-based materials such as: laminated chipboards and medium-density fiberboards (MDF). Based on the results obtained one can conclude that the laminated chipboards may affect the indoor air quality in much...
-
Application of the Chimney Cap as a Method of Improving the Effectiveness of Natural Ventilation in Buildings
PublikacjaAdequately designed natural ventilation is the cheapest and easiest way to effectively remove indoor pollutants and keep the air inside a building fresh. A prediction of the performance and effectiveness of ventilation in order to determine the design of a ventilation system can provide real and long-term cost savings. The worst time in terms of the efficiency of natural ventilation is the spring-autumn transition period [7]. In...
-
Mitigation effect of face shield to reduce SARS-CoV-2 airborne transmission risk: Preliminary simulations based on computed tomography
PublikacjaWe aimed to develop a model to quantitatively assess the potential effectiveness of face shield (visor) in reducing airborne transmission risk of the novel coronavirus SARS-CoV-2 during the current COVID-19 pandemic using the computational fluid dynamics (CFD) method. The studies with and without face shield in both an infected and healthy person have been considered in indoor environment simulation. In addition to the influence...
-
Mitigation effect of face shield to reduce SARS-CoV-2 airborne transmission risk: Preliminary simulations based on computed tomography
PublikacjaWe aimed to develop a model to quantitatively assess the potential effectiveness of face shield (visor) in reducing airborne transmission risk of the novel coronavirus SARS-CoV-2 during the current COVID-19 pandemic using the computational fluid dynamics (CFD) method. The studies with and without face shield in both an infected and healthy person have been considered in indoor environment simulation. In addition to the influence...
-
Selected concentration techniques for gas chromatographic analysis of environmental samples
PublikacjaThe paper describes the role and tasks of environmental analysis and monitoring. It emphasises the leading role played by gas chromatography, especially when coupled with suitable sample preparation. This is demonstrated by some literature evidence and mainly by the author's original work on the design of sample preparation apparatus and development of GC-based methods of determination of a wide variety of organic pollutants in...
-
Application of passive sampling techniques as a usable tool in the field of environmental quality monitoring
PublikacjaAnalysis of literature data published for the past 20 years leads to the conclusion, that passive sampling technique has been developing very quickly and is commonly used in the field of monitoring pollutants in air, water and soil environment. The popularity of application of passive sampling techniques in analytical and environmental chemistry results from its many advantages e.g.: Simplicity in use, low costs of exploitation,...
-
Wpływ emisji Lotnych Związków Organicznych (LZO), na jakość powietrza w pomieszczeniach wnętrz
PublikacjaNa jakość powietrza w pomieszczeniach wnętrz (ang. Indoor Air Quality, IAQ) mają wpływ zarówno czynniki fizyczne (np. hałas, temperatura, wilgotność powietrza) jak i czynniki chemiczne (m.in. Lotne Związki Organiczne, LZO) oraz biologiczne (np. mikroorganizmy). W przypadku czynników chemicznych, istotną grupę związków stanowią głównie LZO (np. węglowodory aromatyczne, alifatyczne). Ponad połowa emisji tych związków pochodzi z materiałów...
-
Improved energy management technique in pipe-embedded wall heating/cooling system in residential buildings
PublikacjaEffective and environmentally responsive techniques of energy management in residential buildings are desirable for the resulting reduction of energy costs and consumption. In this paper, an improved and efficient technique of energy management in pipe-embedded wall heating/cooling systems, called the Thermal Barrier, is described. Specifically, the Thermal Barrier is a technique focused on the management and control of heat...
-
Improved energy management technique in pipe-embedded wall heating/cooling system in residential buildings
PublikacjaEffective and environmentally responsive techniques of energy management in residential buildings are desirable for the resulting reduction of energy costs and consumption. In this paper, an improved and efficient technique of energy management in pipe-embedded wall heating/cooling systems, called the Thermal Barrier, is described. Specifically, the Thermal Barrier is a technique focused on the management and control of heat supply...
-
Understanding the early-stage release of volatile organic compounds from rapeseed oil during deep-frying of tubers by targeted and omics-inspired approaches using PTR-MS and gas chromatography
PublikacjaDuring deep-frying, a plethora of volatile products is emitted with the fumes. These compounds could act as oil quality indicators and change the indoor air composition leading to health risks for occupants. The presented experiments focus on deep-frying of different tubers in rapeseed oil at different frying temperatures. Here, two scenarios for real-time monitoring of volatile organic compounds (VOCs) using proton transfer reaction...
-
Determination of polybrominated diphenyl ethers in house dust using standard addition method and gas chromatography with electron capture and mass spectrometric detection
PublikacjaMonitoring of the environmental fate of polybrominated diphenyl ethers (PBDEs) involves determination of their concentration in air, airborne particles and settled dust. This requires the implementation of appropriate analytical tools like measuring instruments, reference materials and analytical procedures. In this study an analytical procedure was developed for determining PBDEs in samples with a complex matrix composition. The...
-
Online Volatile Compound Emissions Analysis Using a Microchamber/Thermal Extractor Coupled to Proton Transfer Reaction-Mass Spectrometry
PublikacjaIndoor air is a complex and dynamic mixture comprising manifold volatile organic compounds (VOCs) that may cause physiological and/or psychological discomfort, depending on the nature of exposure. This technical note presents a novel approach to analyze VOC emissions by coupling a microchamber/thermal extractor (μ-CTE) system to a proton transfer reaction-mass spectrometer (PTR-MS). This configuration provides an alternative to...
-
The influence of local temperature and air velocity changes on the thermal sensations of users' working in surgical clothing
Publikacja -
Analysis of Accuracy of Modified Gradient Method in Indoor Radiolocalisation System
PublikacjaIn this paper a new method, called modified gradient method, has been proposed for position calculation on the basis of distance measurement in indoor environment. It is shown that well known method of position calculation such as Foy is inefficient in indoor environment. In this article is also described the indoor radiolocalisation system which was used for collecting distance measurements which were employed for further comparative...
-
Performance comparison of new modified gradient algorithm and Foy algorithm for iterative position calculation
PublikacjaIn the paper a new position calculation algorithm is presented. It is proposed for indoor environments and is called modified gradient algorithm. This algorithm is compared with well-known Foy algorithm. The comparative analysis is based on real distance measurements conducted in indoor environment.