Pounding-involved response of isolated and non-isolated buildings under earthquake excitation
PublikacjaCelem artykułu jest dokładna analiza zachowania się kolidujących ze sobą dwóch budynków z wibroizolacją i bez wibroizolacji poddanych obciążeniom dynamicznym podczas trzęsień ziemi. W analizie rozważno przypadki kiedy oba budynki mają wibroizolację, kiedy tylko jeden budynek ma wibroizolację oraz kiedy żaden z budynków nie ma wibroizolacji. Wyniki badań pokazują, iż budynki z wibroizolacją są bardziej podatne na zderzenia podczas...
-
Earthquake-Induced Pounding of Medium-to-High-Rise Base-Isolated Buildings
PublikacjaDuring earthquakes, out-of-phase vibrations in adjacent buildings with limited distance may cause pounding between them. In recent years, the use of seismic isolation has expanded considerably as an effective approach to reduce seismic damage. However, the isolated building experiences large displacements during earthquakes, and there is a possibility of collisions with adjacent structures. The research on earthquake-induced pounding...
-
Simulation of the response of base-isolated buildings under earthquake excitations considering soil flexibility
PublikacjaThe accurate analysis of the seismic response of isolated structures requires the incorporation of the flexibility of supporting soil. However, it is often customary to idealize the soil as rigid during the analysis of such structures. In the present paper, seismic response time history analyses of base-isolated buildings modelled as single degree-of-freedom (SDOF) and multi degree-of-freedom (MDOF) systems with linear and nonlinear...
-
The Effectiveness of Rubber Bumpers in Reducing the Effects of Earthquake-Induced Pounding between Base-Isolated Buildings
PublikacjaTh e methods for preventing earthquake-induced structural pounding between two adjacent buildings include ensuring a sufficient separation distance between them or decreasing their relative displacement during seismic excitation. Some equations or even specific values of such gap sizes between two buildings have been introduced so as to avoid collisions. Increasing the stiffness of buildings, using tuned mass dampers, applying...
-
Seismic pounding between adjacent buildings: Identification of parameters, soil interaction issues and mitigation measures
PublikacjaStructural pounding has been observed in many previous earthquakes due to insufficient gap commonly provided between adjacent structures. The collisions usually generate large impact forces and short duration acceleration pulses which may result in significant damage to the colliding buildings. Because of that, earthquake induced structural pounding has been intensively studied and investigated for the last three decades. Results...
-
Non-linear behaviour of base-isolated building supported on flexible soil under damaging earthquakes
PublikacjaSeismic isolation is a strategy to reduce damage of structures exposed to devastating earthquake excitations. Isolation systems, applied at the base of buildings, lower the fundamental frequency of the structure below the range of dominant frequencies of the ground motion as well as allow to dissipate more energy during structural vibrations. The effectiveness of the base-isolated buildings in damage reduction has been confirmed...
-
The role of isolated farmsteads in the open landscape protection on the example of Kashubia
PublikacjaAs a result of the social and economic transformation of rural areas, open landscapes are disappearing. Former farmsteads are being devastated or beginning to lose their landscape context due to the spread of residential building development. At the same time, in many places, the farmstead form is clearly legible and remains an element with which the view is structured and enriched. The article was aimed at drawing attention to...
-
Numerical evaluation of dynamic response of an experimentally tested base-isolated and fixed-base steel structure model
PublikacjaSeismic isolation is recognized as one of the most popular and effective methods of protecting structures during earthquake. The present paper is focused on the comparison be-tween the dynamic responses of buildings with fixed and isolated bases exposed to seismic exci-tations. The aim of the study is to investigate the effectiveness of a simplified base isolation numerical modelling technique using the linear springs. One-storey...
-
Measurements of Thermal Conductivity of LWC Cement Composites Using Simplified Laboratory Scale Method
PublikacjaThe implementation of low-energy construction includes aspects related to technological and material research regarding thermal insulation. New solutions are sought, firstly, to reduce heat losses and, secondly, to improve the environment conditions in isolated rooms. The effective heat resistance of insulating materials is inversely proportional to temperature and humidity. Cement composites filled with lightweight artificial...