Filtry
wszystkich: 14
Wyniki wyszukiwania dla: ROTOR FAULT
-
Noninvasive method for rotor fault diagnosis in inverter fed induction motor drive
PublikacjaThis article presents a proposal, simulation and experimental results of a noninvasive rotor fault diagnosis method for the inverter fed induction motor drive. Comparing to reported methods the proposed one does not require any load, rotor brake, slip, mechanical or electrical system physical modification e.g. machine disassembly and can be applied regardless the rotor speed measurement or estimation method.
-
Broken Rotor Symptons in the Sensorless Control of Induction Machine
PublikacjaInverter fed sensorless controlled variable speed drives with induction machine are widely used in the industry applications, also in wind power generation and electric vehicles. On-line self diagnostic systems implementation is needed for early stage fault detection and avoiding a critical fault. Diagnostic algorithms in modern DSP-based controllers can operate simultaneously with control system functions. In the closed-loop controlled...
-
Fast Real-Time RDFT- and GDFT-Based Direct Fault Diagnosis of Induction Motor Drive
PublikacjaThis paper presents the theoretical analysis and experimental verification of a direct fault harmonic identification approach in a converter-fed electric drive for automated diagnosis purposes. On the basis of the analytical model of the proposed real-time direct fault diagnosis, the fault-related harmonic component is calculated using recursive DFT (RDFT) and Goertzel DFT (GDFT), applied instead of the full spectrum calculations...
-
State and control system variables sensitivity to rotor asymmetry in the induction motor drive
PublikacjaThe aim of this paper is to undertake analysis and comparison of the closed-loop and sensorless control systems sensitivity to the broken rotor for diagnostic purposes. For the same vector control system induction motor drive analysis concerning operation with the asymmetric motor, broken rotor fault handling and operation were investigated. Reliability, range of stable operation, fault symptoms and application of diagnosis methods...
-
Broken rotor bar impact on sensorless control of induction machine
PublikacjaThe aim of the research is analysis of the sensorless control system of induction machine with broken rotor for diagnostic purposes. Increasing popularity of sensorless controlled variable speed drives requires research in area of reliability, range of stable operation, fault symptoms and application of diagnosis methods. T transformation (Cunha et al.,2003) used for conversion of instantaneous rotor currents electrical circuit...
-
Possibility of Fault Detection in Sensorless Electric Drives
PublikacjaThe work presents a fault detection method for an induction motor drive system with inverter output filter. This approach make use of a load torque state observer, which complete structure is presented along with the used control structure. Moreover, the demonstrated drive system operates without rotor speed measurement in conjunction with the multiscalar control. The verification of the demonstrated idea was performed on an experimental...
-
Sensorless field oriented control for five-phase induction motors with third harmonic injection and fault insensitive feature
PublikacjaThe paper presents a solution for sensorless field oriented control (FOC) system for five-phase induction motors with improved rotor flux pattern. In order to obtain the advantages of a third harmonic injection with a quasi-trapezoidal flux shape, two vector models, α1–β1 and α3–β3, were transformed into d1– q1, d3– q3 rotating frames, which correlate to the 1st and 3rd harmonic plane respectively. A linearization approach of the...
-
Stability Enhancement of Grid-Connected Wind Power Generation System Using PSS, SFCL and STATCOM
PublikacjaThe stability related issues may occur in a power system due to disturbances in generating or loading conditions, especially in the presence of distributed generation (DG) based on renewable energy resources (RERs). This paper proposes a novel strategy for the stability enhancement of a wind power generation system (WPGS) by using a combination of three devices, namely, a power system stabilizer (PSS), resistive superconductor...
-
Sensorless Fault Detection of Induction Motor with Inverter Output Filter
PublikacjaThe paper presents the problem of monitoring and fault detection of a sensorless voltage inverter fed squirrel cage induction motor with LC filter. The detection is based on load torque estimation of the investigated torque transmission system. The load torque is calculated besides the computation of other variables that are mandatory for sensorless drive operation such as rotor flux and speed. The implemented LC filter smooths...
-
Voltage Control of a Stand-Alone Multiphase Doubly Fed Induction Generator
PublikacjaThis article presents a multiphase doubly fed induction generator (MDFIG) with a dedicated and unique control algorithm in a stand-alone wind energy conversion system. The algorithm has been developed and elaborated in the case of different emergency modes. Compared with the traditional double-fed induction generator, the MDFIG has increased reliability, reduced current level per phase, and low rotor harmonic currents. The control...
-
Nonlinear model of a synchronous generator for analysis of more electric aircraft power systems
PublikacjaA nonlinear model for studying a variable-speed synchronous generator (SG) in more electric aircraft (MEA) power system has been developed. The saturation effects of the SG magnetic circuit have been considered. The model has been implemented in the Synopys/Saber simulation environment. The modelling language MAST has been used to elaborate the SG model. The model exhibit a network with the same number of external terminals/ports...
-
Fault-tolerant performance of the novel five-phase doubly-fed induction generator
PublikacjaThe article presents the concept of a new design of a multi-phase doubly-fed induction generator (DFIG). The innovative design approach uses a five-phase power supply from the rotor side of the generator with a three-phase classic stator power supply. Modern three-phase doubly-fed induction generators are the dominant choice for Wind Energy Conversion Systems (WECS). Solutions of this type are sensitive to the loss of at least...
-
Design advantages and analysis of a novel five-phase doubly-fed induction generator
PublikacjaPurpose – The purpose of this paper is to provide an analysis of the performance of a new five-phase doubly fed induction generator (DFIG). Design/methodology/approach – This paper presents the results of a research work related to fivephase DFIG framing, including the development of an analytical model, FEM analysis as well as the results of laboratory tests of the prototype. The proposed behavioral level analytical model is based...
-
Modelling and analysis of a synchronous generator in more electric aircraft power system using Synopsys/Saber simulator = Modelowanie i analiza generatora synchronicznego w systemie elektroenergetycznym nowoczesnego samolotu. Zastosowanie symulatora Synopsys/Saber
PublikacjaStreszczenie angielskie: A model for studying synchronous machine (SM) dynamic behaviour in more electric aircraft (MEA) power system is developed and implemented in the Synopys/Saber simulation environment. The modelling language MAST has been used to elaborate the SM model. The elaborated model exhibit a network with the same number of external terminals/ports as the real SM, and represents its behaviour in terms of the electrical...