Wyniki wyszukiwania dla: SINUSOIDAL INVERTER - MOST Wiedzy

Wyszukiwarka

Wyniki wyszukiwania dla: SINUSOIDAL INVERTER

Wyniki wyszukiwania dla: SINUSOIDAL INVERTER

  • Errors in the analysis of series resonant inverter/converter assuming sinusoidal waveforms of voltage and current

    Publikacja

    - Rok 2016

    In this paper the theory and simulation results of the series resonant inverter / converter are presented. In this work the authors carried out a detailed comparative analysis of results obtained using the method of AC analysis in the steady state for the first harmonic with the results of computer simulation. The AC analysis under certain conditions can lead to errors disqualifying this method. In particular, these errors appear...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Integrated Three-Level Dual-Phase Inverter

    Publikacja

    - ENERGIES - Rok 2022

    In view of reducing the number of inverter legs that provide dual-phase, three-level output voltages (as may be needed in an uninterruptible power supply), and that also provide a wide range of output frequencies (as needed in an advanced motor drive system with wide speed ranges), a three-level, dual-phase inverter topology is presented in this paper. Its three-level attribute was based on the F-type inverter topological concept,...

    Pełny tekst do pobrania w portalu

  • Pulse-Width Modulation Template for Five-Level Switch-Clamped H-Bridge-Based Cascaded Multilevel Inverter

    Publikacja

    - ENERGIES - Rok 2021

    This article presents a carrier-based pulse-width modulation (PWM) template for a 5-level, H bridge-based cascaded multilevel inverter (MLI). The developed control concept generates adequate modulation template for this inverter topology wherein a sinusoidal modulating waveform is modified to fit in a single triangular carrier signal range. With this modulation approach, classical multiplicity and synchronization of the triangular...

    Pełny tekst do pobrania w portalu

  • Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives

    Publikacja

    - Rok 2005

    This paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Piotr Chrzan prof. dr hab. inż.

    Urodził się w 1954 r. w Sopocie. Jest absolwentem Wydziału Elektroniki Politechniki Gdańskiej (1978). W 1980 r. podjął pracę na Wydziale Elektrycznym w zespole prof. Jerzego Jaczewskiego. W 1988 r. uzyskał stopień naukowy doktora nauk technicznych, habilitację w 1999 r., w zakresie elektrotechniki: energoelektroniki i automatyki napędu, a tytuł profesora w 2017 r. Był promotorem 6 obronionych prac doktorskich (w tym 3 z wyróżnieniem)....

  • Single-phase, Five-level Inverter with SPWM-Based Neutral Point Voltage Balancing Scheme

    Publikacja

    Multilevel inverter topologies provide several advantages over two-level inverter configuration. These benefits are the reason for the growing interest in multilevel topologies among research society. One of the most popular topological concepts (diode and active switch clamping) requires neutral-point potential balancing due to series-connected capacitor banks across the input dc link in such derived inverter configurations. This...

    Pełny tekst do pobrania w portalu

  • Modified SPWM Technique with Zero-Sequence Voltage Injection for a Five-Phase, Three-Level NPC Inverter

    Publikacja

    - ENERGIES - Rok 2021

    This article presents a modified sinusoidal pulse-width modulation (SPWM) scheme for a five-phase, three-level neutral-point-clamped inverter. The modulation scheme deploys a modified min–max function to inject the zero-sequence components into the reference modulating signals; hence enabling the effective utilization of the DC-link voltage. Balanced split-input DC-link voltages were achieved through further incorporation of adjustable...

    Pełny tekst do pobrania w portalu

  • A Five-Leg Three-Level Dual-Output Inverter

    Classical 3-level dual-output inverter, 3-L DOI, involves two similar 3-level inverters that provides a pair of 3-phase output voltages with same or different frequencies from common input voltage source. Flexibility of either operation of the constituting inverters is evident in this DOI; but total duplication of power switches is a major drawback. State of the art coupled 3-L DOIs reduce this drawback by providing series-shared...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Five-phase induction motor drive with sine-wave filter

    Publikacja

    - Rok 2014

    The paper presents closed loop ac drive with 5 phase induction motor operating with voltage source inverter and sine wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed co ntrol can be applied. In the presence of output filter both control and estimation algorithms should be modified due to sine wave filter installation....

    Pełny tekst do pobrania w serwisie zewnętrznym

  • SiC-based T-type modules for multi-pulse inverter with coupled inductors

    Publikacja

    - Rok 2017

    The paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Sensorless Fault Detection of Induction Motor with Inverter Output Filter

    Publikacja

    The paper presents the problem of monitoring and fault detection of a sensorless voltage inverter fed squirrel cage induction motor with LC filter. The detection is based on load torque estimation of the investigated torque transmission system. The load torque is calculated besides the computation of other variables that are mandatory for sensorless drive operation such as rotor flux and speed. The implemented LC filter smooths...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Dead time effects compensation strategy by third harmonic injection for a five-phase inverter

    This paper proposes a method for compensation of dead-time effects for a fivephase inverter. In the proposed method an additional control subsystem was added to the field-oriented control (FOC) scheme in the coordinate system mapped to the third harmonic. The additional control loop operates in the fixed, orthogonal reference frame ( α - β coordinates) without the need for additional Park transformations. The purpose of this method...

    Pełny tekst do pobrania w portalu

  • A Single-Carrier-Based Pulse-Width Modulation Template for Cascaded H-Bridge Multilevel Inverters

    Publikacja

    - IEEE Access - Rok 2021

    Multiplicity of the triangular carrier signals is a criterion for the extension of sinusoidal pulsewidth modulation, SPWM, to a number of output voltage levels per phase-leg in cascaded H-bridge (CHB) multilevel inverter (MLI). Considering medium and high voltage applications where appreciable number of output voltage levels from CHB MLI is needed, commensurate high number of carrier signals in either classical level- or phase-shifted...

    Pełny tekst do pobrania w portalu

  • EMC disturbances in connection of driving system

    Publikacja

    - Rok 2003

    It is known the steep voltage changes caused by IGBT frequency inverters may cause some electromagnetic problems in driving system. Special dU/dt type as well as sinusoidal filters are used in order to limit the level of the disturbances. The paper presents investigation results of EMC disturbances in inverter supplied induction motor. Experiments have proved that disturbances in current connection differ essentially. Important...

  • Space vector modulation in multilevel inverters of the servo drives of the trajectory measurements telescopes

    Publikacja

    - Izvestiya vysshikh uchebnykh zavedeniy. Priborostroenie - Rok 2017

    Using the MatLab/Simulink mathematical model of a three-phase three-level voltage inverter, the influence of the space-vector modulation (SVM) algorithm on the pulsations of the current (torque) of an AC motor in the range of low rotation speeds is considered. It is shown that the SVM of the second kind does not provide a pulsations level comparable to the pulsations of a sinusoidal pulse-width modulation (SPWM), both in the static...

    Pełny tekst do pobrania w portalu

  • Electric shock hazard in circuits with variable-speed drives

    The conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50/60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives...

    Pełny tekst do pobrania w portalu

  • Audible noise in ship’s electrical drive systems with frequency converters

    Dane Badawcze
    open access

    The presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.

  • Dynamic characteristics of the proton exchange membrane fuel cell module

    The paper describes a fuel cell based system and its performance. The system is based on two fuel cell units, DC/DC converter, DC/AC inverter, microprocessor control unit, load unit, bottled hydrogen supply system and a set of measurement instruments. In the study presented in the paper a dynamic response of the proton exchange membrane (PEM) fuel cell system to unit step change load as well as to periodical load changing cycles...

    Pełny tekst do pobrania w portalu

  • A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux

    Publikacja

    - ENERGIES - Rok 2020

    In this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...

    Pełny tekst do pobrania w portalu

  • Hybridized PWM Strategy for Three- and Multiphase Three-Level NPC Inverters

    A simple hybridized pulsewidth modulation (PWM) algorithm for three- and multiphase three-level neutral point clamped (NPC) inverters is proposed. The proposed solution is based on classical space vector PWM (SVPWM) algorithms for two-level inverters but can also be based on sinusoidal PWM with min–max injection. An additional level of output voltage is obtained by modifying the resulting switching patterns taking into account...

    Pełny tekst do pobrania w portalu

  • Sensorless induction motor drive with voltage inverter and sine-wave filter

    Publikacja

    - Rok 2013

    This paper presents a speed sensorless control system of an induction motor with an output LC filter. It is known that the parameters design of the filter gives sine wave motor supply voltage but complicates control and estimation process. The reason is that the voltage drop and phase shift between filter input and output signals are imposed, and hence the motor voltages and currents differ from the inverter output waveforms. To...

    Pełny tekst do pobrania w serwisie zewnętrznym