Filtry
wszystkich: 1435
-
Katalog
- Publikacje 899 wyników po odfiltrowaniu
- Czasopisma 68 wyników po odfiltrowaniu
- Konferencje 1 wyników po odfiltrowaniu
- Osoby 20 wyników po odfiltrowaniu
- Projekty 4 wyników po odfiltrowaniu
- Kursy Online 2 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 440 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: AORTIC DISSECTION.
-
Late Aortic Remodeling after Endovascular Repair of Complicated Type B Aortic Dissection—TEVAR Protects Only the Covered Segment of Thoracic Aorta
PublikacjaIntroduction: TEVAR is the preferred way of treatment of complicated type B aortic dissection. The purpose of the study was to assess the impact of TEVAR on aortic remodelling in the thoracic and abdominal segment in long-term follow-up. Methods: 23 patients with complicated type B aortic dissection were treated by TEVAR in years 2004-2012 in our Department. Aortic remodelling was rated based on preoperative and final follow-up...
-
Catheter-induced coronary artery and aortic dissections. A study of the mechanisms, risk factors, and propagation causes
PublikacjaBackground: Only the incidence, management, and prognosis of catheter-induced coronary artery and aortic dissections have been systematically studied until now. We sought to evaluate their mechanisms, risk factors, and propagation causes. Methods: Electronic databases containing 76,104 procedures and complication registries from 2000– –2020 were searched and relevant cineangiographic studies adjudicated. Results: Ninety-six dissections...
-
Numerical Model of the Aortic Valve Implanted Within Real Human Aorta
PublikacjaCardiovascular system diseases are the main cause of deaths in developed and developing countries. The main reasons are myocardial infarction, heart failure, stroke and valvular diseases. These are caused mainly by arteriosclerosis. The valvular diseases involve a significant burden for the health care system and their frequency is rising with the patient age. This work describes the tools and numerical models appropriate for modeling...
-
Strategic Direction
Czasopisma -
Regarding to functional outcomes after extracapsular dissection with partial facial nerve dissection for small and large parotid neoplasms
Publikacja -
Calculations of electron impact ionization cross section for simple biomolecules: formic and acetic acids
PublikacjaObliczono przekroje czynne na jednokrotną jonizację kwasu mrówkowego oraz kwasu octowego. Obliczenia przeprowadzono używając formalizmu BEB w zakresie energii od progu na jonizację do 400 eV. Wyniki porównano z dostępnymi danymi doświadczalnymi.
-
Endoscopic submucosal dissection of gastric ectopic pancreas
Publikacja -
Comparative in vitro research of the Human Aortic Bioprosthesis
PublikacjaE valuate of the usefulness and reliability of structures based on the analysis of recorded parameters determining the flow through the Human Aortic Bioprosthesis (HAB) have been dealt with. By flow parameters changes determining the performance environment of prosthesis analyzed change of the motion dynamics of the valve leaflets as a function of pressure, thereby determining the degree of alignment of the prosthesis to the performance...
-
Pharmacokinetics and pharmacodynamics of propofol in patients undergoing abdominal aortic surgery
Publikacja -
In Vitro Study of a Stentless Aortic Bioprosthesis Made of Bacterial Cellulose
Publikacja -
Long-term mortality after transcatheter aortic valve implantation for aortic stenosis in immunosuppression-treated patients: a propensity-matched multicentre retrospective registry-based analysis
PublikacjaIntroduction Data regarding patients with a previous medical record of immunosuppression treatment who have undergone transcatheter aortic valve implantation (TAVI) are limited and extremely inconclusive. Available studies are mostly short term observations; thus there is a lack of evidence on efficacy and safety of TAVI in this specific group of patients. Aim To compare the in-hospital and long-term outcomes between patients...
-
Acute hypertensive response in ischemic stroke is associated with increased aortic stiffness
Publikacja -
Aortic Stiffness Predicts Functional Outcome in Patients After Ischemic Stroke
Publikacja -
Measurements of electron scattering in the backward direction
PublikacjaPrzedstawiono wyniki badań rozproszenia elektronów na atomach i cząsteczkach przeprowadzonych w zakresie dużych kątów rozproszenia do 180o.
-
Distributed graph searching with a sense of direction
PublikacjaIn this work we consider the edge searching problem for vertex-weighted graphs with arbitrarily fast and invisible fugitive. The weight function w provides for each vertex v the minimum number of searchers required to guard v, i.e., the fugitive may not pass through v without being detected only if at least w(v) searchers are present at v. This problem is a generalization of the classical edge searching problem, in which one has...
-
Aortic stiffness is not only associated with structural but also functional parameters of retinal microcirculation
Publikacja -
Association of left atrial fibrosis with aortic excess pressure and white matter lesions
Publikacja -
Aortic excess pressure and arterial stiffness in subjects with subclinical white matter lesions
Publikacja -
Cost-Effectiveness of Open Repair of Abdominal Aortic Aneurysms with a Novel Perioperative Protocol
Publikacja -
Multiscale model for blood flow after a bileaflet artificial aortic valve implantation
PublikacjaCardiovascular diseases are the leading cause of mortality in the world, mainly due to atherosclerosis and its consequences. The article presents the numerical model of the blood flow through artificial aortic valve. The overset mesh approach was applied to simulate the valve leaflets motion and to realize the moving mesh, in the aortic arch and the main branches of cardiovascular system. To capture the cardiac system’s response...
-
Fluid–Structure Interaction methods for the progressive anatomical and artificial aortic valve stenosis
PublikacjaCardiovascular system diseases, as aortic valve stenosis, are the main cause of mortality and morbidity among patients. There is still a room for enhancement of the diagnostic and therapeutic procedures, which will lead to improvement of the treatment. One of the remedies are the computer tools to support the medical diagnoses and prostheses design. The development of a procedure for modeling the aortic valves: anatomical tricuspid...
-
The Courts Public image - The Desired Direction of Change
PublikacjaThis paper proposes to scientifically explore notions of court identity, principles of shaping a court system's image, and best practices in positive court image development relating to thhe courts in Poland
-
IL-22 modulates inflammatory properties of human primary aortic smooth muscle cells
Publikacja -
Cost Effectiveness of Open Repair of Abdominal Aortic Aneurysms with a Novel Peri-Operative Bundle
Publikacja -
Forewarned Is Forearmed: Machine Learning Algorithms for the Prediction of Catheter-Induced Coronary and Aortic Injuries
PublikacjaCatheter-induced dissections (CID) of coronary arteries and/or the aorta are among the most dangerous complications of percutaneous coronary procedures, yet the data on their risk factors are anecdotal. Logistic regression and five more advanced machine learning techniques were applied to determine the most significant predictors of dissection. Model performance comparison and feature importance ranking were evaluated. We identified...
-
General anaesthesia or sedation for percutaneous aortic valve implantation? The questionnaire results and authors’ experience
Publikacja -
ARCTIC
Czasopisma -
Direction-of-Arrival Estimation Methods in Interferometric Echo Sounding
PublikacjaNowadays, there are two leading sea sounding technologies: the multibeam echo sounder and the multiphase echo sounder (also known as phase-dierence side scan sonar or bathymetric side scan sonar). Both solutions have their advantages and disadvantages, and they can be perceived as complementary to each other. The article reviews the development of interferometric echo sounding array configurations and the various methods applied...
-
Dissection of aorta [any part] - Female, 76 - Tissue image [1300630017382511]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 76 - Tissue image [1300630017389121]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 22 - Tissue image [1300630017385241]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 76 - Tissue image [1300630017382311]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 22 - Tissue image [1300630017388761]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 76 - Tissue image [1300630017383261]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 22 - Tissue image [1300630017386351]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 76 - Tissue image [1300630017388151]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 22 - Tissue image [3300730069457391]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 76 - Tissue image [1300630017386101]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 76 - Tissue image [1300630017385801]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 22 - Tissue image [130063001738531]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 76 - Tissue image [1300630017383741]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 22 - Tissue image [1300630017389981]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
The effect of 7-ketocholesterol and 25-hydroxycholesterol on the integrity of the human aortic endothelial and intestinal epithelial barriers
Publikacja -
Noninvasively assessed pulsatility of ascending aortic pressure waveform is associated with the presence of coronary artery narrowing
Publikacja -
Dissecting gamma frequency activities during human memory processing
PublikacjaGamma frequency activity (30-150 Hz) is induced in cognitive tasks and is thought to reflect underlying neural processes. Gamma frequency activity can be recorded directly from the human brain using intracranial electrodes implanted in patients undergoing treatment for drug-resistant epilepsy. Previous studies have independently explored narrowband oscillations in the local field potential and broadband power increases. It is not...
-
Dissection of aorta [any part] - Female, 22 - Tissue image [1300630017387711]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 76 - Tissue image [1300630017382481]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 76 - Tissue image [1300630017384981]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 76 - Tissue image [1300630017388381]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dissection of aorta [any part] - Female, 76 - Tissue image [1300630017386521]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.