Publications
Filters
total: 750
Catalog Publications
-
Porównanie efektów nauczania przed i w czasie nauki zdalnej spowodowanej pandemią SARS-CoV-2 na przykładzie przedmiotu Metrologia
PublicationPrzedmiot Metrologia jest wykładany na semestrze drugim na trzech kierunkach na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej. W ramach wykładu studenci poznają problematykę dokonywania pomiarów. W kolejnym semestrze, przekładają zdobytą teoretycznie wiedzę na praktykę, wykonując pomiary w laboratorium. Z uwagi na wybuch pandemii SARS-CoV-2 w 2020 roku oraz...
-
T1 RELAXATION TIME CALLIBRATION IN MAGNETIC RESONANCE IMAGING USING NANODIAMOND PHANTOMS
PublicationMRI is increasingly used in radiation treatment planning because of the excellent soft tissue contrast in the obtained images. It allows more precise definition of the boundaries between healthy tissues and those affected by cancerous lesions. To obtain good image quality, the difference in signal between two types of tissue must be significant despite the noise so it must be properly calibrated. This calibration includes...
-
Corrigendum to “T1 relaxation time callibration in magnetic resonance imaging using nanodiamond phantoms” [Phys Med 94 (2022) S119–S120/EPV029]
PublicationThe authors want to update the incorrect funding information. The correct funding note is: “The authors acknowledge the financial support from Gdańsk University of Technology by the 4/2020/IDUB/III.4.1/Tc grant under the Technetium Talent Management Grants ‘Excellence Initiative – Research University’. The financial support from Gdańsk University of Technology by the 1/2021/IDUB/II.2/Np grant under NEPTUNIUM Enhancing Baltic Region...
-
Fiber-optic sensors based on microspheres with nanocoatings (Zastosowanie mikrosfer optycznych z cienkowarstwowymi pokryciami w czujnikach światłowodowych)
PublicationTemperature is one of the most important physical quantities. Temperature measurements are used in every field of life, especially electronics, electrical engineering, energy-related fields, including energy source and storage devices. The goal of this dissertation is to design and optimize the microsphere-based fiber-optic sensors construction for measurement of the sensor surrounding medium temperature, including selection of...
-
Tuning of the finesse coefficient of optoelectronic devices
PublicationOptoelectronic devices attracted considerable attention in many branches of science and technology, which can be attributed to their unique properties. Many of them use optical cavities which parameters can be adopted to specific requirements. This thesis investigates the introduction of diamond structures (nitrogen-doped diamond film, boron-doped diamond film, undoped diamond sheet) to optical cavities to tune their finesse coefficient....
-
Diamond Structures for Tuning of the Finesse Coefficient of Photonic Devices
PublicationFinesse coefficient is one of the most important parameters describing the properties of a resonant cavity. In this research, a mathematical investigation of the application of diamond structures in a fiber-optic Fabry–Perot measurement head to assess their impact on the finesse coefficient is proposed. We present modeled transmission functions of cavities utilizing a nitrogen-doped diamond, a boron-doped diamond, nanocrystalline...
-
Multi-functional sensor based on photonic crystal fiber using plasmonic material and magnetic fluid
PublicationA unique highly sensitive photonic crystal fiber is investigated based on plasmonic material and magnetic fluid (MF) for the simultaneous measurement of temperature and magnetic field sensor. The designed sensor is explored by tracing the different parameters such as birefringence, coupling length, power spectrum, and the peak wavelength of the transmission intensity. The magnetic field and temperature computation are attained...
-
Long-Term Measurement of Physiological Parameters – Child Dataset
PublicationThe dataset titled “Long-term measurement of physiological parameters – child is one dataset” of the bigger series named Long-term measurement of physiological parameters. The dataset contains physiological parameter measurements such as skin temperature and resistance, blood pulse, as well as the stress detection marker, which can have a value of 0 when there is no stress detected or 1 when stress appeared. Additionally, the dataset...
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublicationThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
Porous Phantoms Mimicking Tissues – Investigation of Optical Parameter Stability Over Time
PublicationIn terms of optical parameters, optical phantoms can now replace live tissues and be used to validate optical measurement methods. Therefore, whether these parameters would be maintained after storage for 6 months was examined. The absorption and scattering coefficients were obtained from the measured transmittance and reflectance measurements taken 6 months apart and then compared. All of the measurements were conducted using...
-
Measurement of the Temporal and Spatial Temperature Distribution on the Surface of PVCP Tissue Phantom Illuminated by Laser Dataset
PublicationThe dataset entitled Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser was obtained with a laboratory set-up for characterisation of the thermal properties of optical tissue phantoms during laser irradiation. The dataset contains a single image file representing the spatial temperature distribution on the surface of a PVCP tissue phantom. This thermal image...
-
REJESTRACJA SERII ZDJĘĆ, Z WYMUSZENIEM ZMIENNYCH WARUNKÓW OŚWIETLENIOWYCH, JAKO TECHNIKI WSPOMAGAJĄCEJ PRZY AUTOMATYCZNYM ROZPOZNAWANIU TEKSTU
PublicationW artykule przedstawiono autorskie rozwiązania problemu wykonywania zdjęć niewyraźnych tekstów na opakowaniach i niewielkich produktach. W sytuacji gdy napis posiada niską rozdzielczość (drukarka atramentowa), albo jest wykonany poprzez technikę tłoczenia, wykonanie zwykłego, pojedynczego zdjęcia daje przeważnie niezadowalające wyniki. Dzięki przedstawionym tu rozwiązaniom, znacząco polepszamy materiał wejściowy (fotografie), który...
-
Towards spectral sensitivity curve for two-photon vision mechanism
PublicationAbstract Purpose: The perceived brightness of different visible light sources can be compared with photometric units based on the standardized luminosity curves (300-780nm range). As reported previously (PNAS 111(50), pp. E5445-E5454 (2014)), near-infrared (NIR) radiation can cause isomerization of visual pigments by one- or two-photon absorption. The perceived color of the stimulus is red in the case of one-photon vision (1PV)...
-
The electrical, morphological and optical properties of heavily boron-doped diamond sheets as a function of methane concentration in the gas phase
PublicationBoron-doped diamonds (BDD) are known for their excellent properties such as high thermal conductivity, high mobility, low absorption in visible light, and biocompatibility. In this work, we investigated the electrical, morphological and optical properties of heavily boron-doped diamond thin sheets as a function of methane concentration in the gas phase. Free-standing diamond sheets were fabricated using a microwave plasma-assisted...
-
Effect of temperature change on refractive index of an egg white and yolk: a preliminary study
PublicationIn this article, the refractive index of an egg white and yolk depending on temperature in range 30 - 47 °C over 1550 nm was determined. The measurement head was constructed as fiber optic Fabry-Perot interferometer with interference between polished fiber end-face and aluminum weighing dish. The measurement setup has been made of an optical spectrum analyzer, a superluminescent diode with a central wevelength of 1550 nm, 2:1 fiber...
-
Atomic-Scale Finite-Element Modeling of Elastic Mechanical Anisotropy in Finite-Sized Strained Phosphorene Nanoribbons
PublicationNanoribbons are crucial nanostructures due to their superior mechanical and electrical properties. This paper is devoted to hybrid studies of the elastic mechanical anisotropy of phosphorene nanoribbons whose edges connect the terminals of devices such as bridges. Fundamental mechanical properties, including Young’s modulus, Poisson’s ratio, and density, were estimated from first-principles calculations for 1-layer, 3-layer, and...
-
Boron-Doped Diamond/GaN Heterojunction—The Influence of the Low-Temperature Deposition
PublicationWe report a method of growing a boron-doped diamond film by plasma-assisted chemical vapour deposition utilizing a pre-treatment of GaN substrate to give a high density of nucleation. CVD diamond was deposited on GaN substrate grown epitaxially via the molecular-beam epitaxy process. To obtain a continuous diamond film with the presence of well-developed grains, the GaN substrates are exposed to hydrogen plasma prior to deposition....
-
Implementation of SiN thin film in fiber-optic sensor working in telecommunication range of wavelengths
PublicationMirrors are used in optical sensors and measurement setups. This creates a demand for mirrors made of new materials and having various properties tailored to specific applications. In this work, we propose silicon covered with a thin silicon nitride layer as a mirror for near-infrared measurements. SiN layer was deposited on a standard silicon wafer with a Low-Pressure Chemical Vapor Deposition furnace. Then, the created layer...
-
Detection of petroleum products using optical coherence tomography
PublicationIn this work, we present a novel method developed for the analysis of the properties of thin layers for detecting petroleum products on a water surface using a commercially available optical coherence tomography (OCT) system. The spectral density analysis of the signal from a spectroscopic OCT (S-OCT) enables us to perform the precision calculation of the thin layer thickness and other properties like homogeneity, and dispersion,...
-
Możliwości i ryzyka związane z automatyzacją weryfikacji pracy studentów na przykładzie przedmiotu Metrologia
PublicationPrzedmiot Metrologia jest wykładany na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej na trzecim semestrze studiów na trzech kierunkach: Elektronika i Telekomunikacja, Inżynieria Biomedyczna oraz Automatyka, Cybernetyka i Robotyka. W trakcie zajęć laboratoryjnych studenci wykonują sześć ćwiczeń, z których dwa są całkowicie oceniane przez program weryfikujący...
-
Modyfikowane nanodiamentowe warstwy do sensorów z detekcją optyczną i elektrochemiczną
PublicationW rozprawie doktorskiej przedstawiono opracowanie parametrów procesów syntezy osadzania z fazy gazowej wspomaganego plazmą mikrofalową (MWPACVD) do wytwarzania warstw nanodiamentowych o niskim współczynniku absorpcji optycznej i wysokiej przewodności elektrycznej. Warstwy te są przeznaczone do sensorów z detekcją optyczną i elektrochemiczną stosowanych w układzie interferometru Mach-Zehndera do badania in situ modyfikacji elektrod...
-
Design and implementation of the driver system for Hamamatsu C12880MA microspectrometer
PublicationRecent miniaturization developments in devices for spectroscopy have reduced greatly their costs and increased their availability for a wide range of users and applications. This paper presents the design and implementation of a driver system for a Hamamatsu C12880MA microspectrometer. The system implementation was carried out and compared using two independent microcontroller modules: Arduino Uno and STM32F411RE Nucleo. We assessed...
-
Computer support of analysis optical spectra measurements
PublicationVerification of measurement errors has a big impact on assessment of accuracy of conducted measurements and obtained results. In many cases computer simulation results are compared with measurement results in order to evaluate measurement errors. The purpose of our research was to check the accuracy of measurements made with Fabry-Perot interferometer working in the transmission mode. In measurement setup, a 1310 nm superluminescent...
-
Studies on Aminoanthraquinone-Modified Glassy Carbon Electrode: Synthesis and Electrochemical Performance toward Oxygen Reduction
PublicationIn this paper, 9,10-anthraquinone (AQ) derivative-modified glassy carbon (GC) electrodes were studied towards the electrochemical reduction of oxygen in aqueous and non-aqueous solutions. The reaction of 1-chloro-9,10-anthraquinone with aliphatic diamines was applied for the synthesis of amino-9,10-anthraquinone derivatives. The obtained AQ derivatives were grafted onto the surface of glassy carbon electrodes by electropolymerisation...
-
The Optical Coherence Tomography and Raman Spectroscopy for Sensing of the Bone Demineralization Process
PublicationThe presented research was intended to seek new optical methods to investigate the demineralization process of bones. Optical examination of the bone condition could facilitate clinical trials and improve the safety of patients. The authors used a set of complementary methods: polarization-sensitive optical coherence tomography (PS-OCT) and Raman spectroscopy. Chicken bone samples were used in this research. To stimulate in laboratory...
-
Optical-Fiber Microsphere-Based Temperature Sensors with ZnO ALD Coating—Comparative Study
PublicationThis study presents the microsphere-based fiber-optic sensor with the ZnO Atomic Layer Deposition coating thickness of 100 nm and 200 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range from 100 °C to 300 °C, with a 10 °C step. The interferometric signal was used to monitor the integrity of the microsphere and its attachment to the connecting fiber. For the sensor...
-
Surface quality control of a thin SiN layer by optical measurements
PublicationFiber optic interferometers have a wide range of applications, including biological and chemical measurements. Nevertheless, in the case of a reflective interferometer setup, standard silver mirrors cannot be used in every measurement, due to their chemical activity. This work investigates the surface quality of a thin optical layer of silicon nitride (SiN), which can serve as an alternative material for silver mirrors. We present...
-
Zastosowanie czasowo-częstotliwościowej analizy sygnałów dla poprawy właściwości metrologicznych systemów optycznej tomografii koherentnej
PublicationOptyczna tomografia koherentna (OCT) jest metodą obrazowania wewnętrznej struktury obiektów rozpraszających promieniowanie optyczne. Metoda ta wykorzystuje interferometrię niskokoherentą do pomiaru czasu przelotu promieniowania wstecznie rozproszonego od elementów struktury obrazowanego obiektu z rozdzielczością w zakresie od jednego do kilkunastu mikrometrów. Rozprawa dotyczy dwóch rozszerzeń metody OCT. Pierwsze z nich – polaryzacyjna...
-
Effect of pH on optical sensing with poly-L-lysine-modified nanodiamonds
PublicationNitrogen-vacancy (NV) centers are crystallographic defects which provide diamonds with unique physical properties. The centers are known for their intensive, time-stable fluorescence, and an electron spin, which exhibits long coherence time and may be manipulated using external stimuli. Nanodiamonds containing the NV centers are promising tools in biolabeling, biosensing, and drug delivery due to the aforementioned properties of...
-
Analiza danych pomiarowych na potrzeby obrazowania optyczną tomografią koherentną
PublicationW rozdziale omówiono wybrane aspekty związane z analizą danych pomiarowych na potrzeby obrazowania metodą optycznej tomografii koherentnej. Przedstawiono podstawowe zależności umożliwiające obrazowanie tkanek na podstawie analizy promieniowania wstecznie rozproszonego, mierzonego przez systemy OCT pracujące w dziedzinie czasu (TD-OCT) lub w dziedzinie częstotliwości (FD-OCT). Pokazano, że wykorzystując zaawansowane przetwarzanie...
-
Ocena i predykcja dynamiki epidemii COVID-19 na podstawie obecności wirusa SARS-CoV-2 w ściekach
PublicationCOVID-19 - wywołany przez wirusa SARS-CoV-2, prowadzący m.in. do ostrej niewydolności oddechowej, spowodował kryzys w służbie zdrowia i istotne implikacje społeczno-gospodarcze. Główną drogą przenoszenia SARS-CoV-2 jest droga kropelkowa, czyli aerozole z dróg oddechowych, generowane przez kaszel, kichanie i mówienie. Zakażenie SARS-CoV-2 może nie tylko wpływać na układ oddechowy, powodując gorączkę, kaszel, wyciek z nosa, duszność...
-
PHASE OBJECT OBSERVATION SYSTEM BASED ON DIFFRACTION PHASE MICROSCOPY
PublicationIn the paper authors present a special measurement system for observing phase objects. The diffraction phas microscopy makes it possible to measure the dimensions of a tested object with a nanometre resolution. To meet this requirement, it is proposed to apply a spatial transform. The proposed setup can be based either on a two lenses system (called 4 f ) or a Wollaston prism. Both solutions with all construction aspects are described...
-
Wyrażanie niepewności za pomocą przedziałów
PublicationZ perspektywy dwóch różnych interpretacji prawdopodobieństwa - klasycznej (częstościowej) i subiektywnej (bayesowskiej) oraz propozycji nowego przewodnika ustalającego zasady obliczania i wyrażania niepewności pomiaru (GUM), porównano sposoby komunikowania niepewności za pomocą przedziałów: ufności, bayesowskiego, objęcia, rozszerzenia.
-
Mikromocowe układy mikrokontrolerowe jako narzędzie badania metod pomiaru małych energii
PublicationEstymacja poboru energii układów mikromocowych nie jest zbyt obszernie opisywana w literaturze, choć temat ten staje się coraz bardziej popularny. Testowanie metod i urządzeń pomiarowych małych energii wymaga zastosowania odpowiedniego podejścia. W tym celu zaproponowano zestaw mikrokontrolerowych urządzeń mikromocowych, które reprezentują typowe profile poboru energii i pozwalają praktycznie weryfikować nowe metody estymacji poboru...
-
REALIZACJA ELEMENTÓW SKŁADOWYCH ŁĄCZA RADIOWEGO Z UŻYCIEM URZĄDZEŃ RADIA PROGRAMOWALNEGO TYPU USRP
PublicationPrzez ostatnią dekadę projektowanie systemów radiowych zaczęło w coraz większym stopniu polegać na cyfrowym przetwarzaniu sygnałów. Możliwość i moc obliczeniowa procesorów ogólnego przeznaczenia GPP (General Purpose Processor), procesorów sygnałowych DSP (Digital Signal Processor) oraz układów programowalnych FPGA (Field Programmable Gate Array) znacząco wzrosła zgodnie z prawem Moor’a. Naturalnym następstwem tego trendu było większe...
-
Wykorzystanie potencjometrów cyfrowych do testowania metod dynamicznej spektroskopii impedancyjnej
PublicationPrzedmiotem artykułu jest opracowanie modelu układu elektrochemicznego o zmiennej w czasie impedancji. Do konstrukcji modelu wykorzystano potencjometry cyfrowe sterowane mikrokontrolerem, pozwala to programowo kontrolować zmiany impedancji modelu. Odpowiednie ukształtowanie zmian widm impedancyjnych w funkcji czasu (impedancjogramów) pozwala na ustalenie ograniczeń różnych metod pomiaru impedancji.
-
BEZPRZEWODOWY SYSTEM MONITOROWANIA WARUNKÓW WEWNĄTRZ SZKLARNIOWYCH
PublicationW referacie zaprezentowano projekt oraz realizację bezprzewodowego systemu do monitorowania parametrów panujących wewnątrz szklarni, takich jak temperatura, wilgotność powietrza i wilgotność gleby. W artykule przedstawiono zasadę działania systemu oraz schematy blokowe, elektryczne i PCB wykonanych urządzeń.
-
The Influence of LED Lighting Sources on the Nature of Power Factor
PublicationThis article presents measurements of electric power absorbed by a newly built facility for office and scientific research activities. These measurements highlighted the need for compensation of capacitive reactive power—not predicted by the designer—due to the vast use of LED lighting in the facility. The article also describes a reactive power compensation system, designed on the basis of the above-mentioned measurements, and...
-
1D portable optical coherence tomography system
Publication—Imaging methods are an expanding branch of technology, which involves data acquisition and analysis of images for research and diagnostics. This paper has been devoted to the description of the optical design for a one-dimensional, portable optical coherence tomography (OCT) system. The Mach-Zehnder interferometer has been designed in the presented study. The description of the construction and applied hardware solutions have...
-
Programmable dynamically changing RC model for evaluation of Dynamic EIS methods and instrumentation
PublicationThe paper concerns the RC equivalent circuit of electrochemical cell with the impedance changed during the experiment. The model was constructed using the digital potentiometers controlled by the microcontroller. This solution allows to control the model impedance by the software means. By creating adequate changes of the impedance spectrum as a time function, the different impedance measurement method can be tested to find out...
-
Model of noise sources in supercapacitors
PublicationThe paper presents detailed model of noise sources in supercapacitors. Noise phenomena observed in supercapacitors may be used as a diagnostic tool for assessment of supercapacitor quality or degradation mechanisms (e.g. corrosion of the electrodes or cloggin g up the pores) during ageing. Therefore, it is important to consider where noise is generated. The equivalent circuit of noise sources existing...
-
A random signal generation method for microcontrollers with DACs
PublicationA new method of noise generation based on software implementation of a 7-bit LFSR based on a common polynomial PRBS7 using microcontrollers equipped with internal ADCs and DACs and a microcontroller noise generator structure are proposed in the paper. Two software applications implementing the method: written in ANSI C and based on the LUT technique and written in AVR Assembler are also proposed. In the method the ADC results are...
-
Niskokoherencyjne czujniki światłowodowe wykorzystujące cienkowarstwowe struktury nanodiamentowe
PublicationZnaczny rozwój technologii wytwarzania czujników światłowodowych spowodował, że są one powszechnie dostępne i stosowane w wielu gałęziach przemysłu, nauki oraz medycyny. Zastosowanie nowych materiałów w konstrukcji takich czujników niesie za sobą duży potencjał. Celem rozprawy jest przedstawienie możliwości wykorzystania cienkowarstwowych struktur nanodiamentowych w niskokoherencyjnych czujnikach światłowodowych, które poprawią...
-
Ocena jakości superkondensatorów wybranymi metodami, wykorzystując zjawiska losowe i badania rozkładu temperatury
PublicationW artykule przedstawiono metody analizy jakości wykonania próbek superkondensatorów na podstawie pomiarów szumów generowanych w ich strukturach oraz rozkładów temperatury na ich powierzchni. Prezentowane metody zostały porównane z obecnie stosowanymi parametrami oceny jakości tych elementów. Wyniki uzasadniają wprowadzenie dodatkowych parametrów, pozwalających oceniać jakość superkondensatorów.
-
Fluctuation-Enhanced Sensing
PublicationFluctuation-enhanced sensing (FES) is an exciting and relatively new research field that promises to extend the range of information that can be extracted from a single sensor. In FES, the stochastic fluctuations of the sensor signal, rather than its average value, are recorded and analyzed. Typical components of such fluctuations are due to interactions at the microscopic level. Proper statistical analysis provides optimum sensory...
-
PROJEKT LISTWY ZASILAJĄCEJ W OPARCIU O KONCEPCJĘ INTERNETU RZECZY
PublicationW referacie przedstawiono podstawowe uwarunkowania, jakimi należy kierować się przy opracowywaniu urządzeń należących do klasy obiektów określanych mianem „Internetu Rzeczy” na przykładzie zrealizowanego prototypu listwy zasilającej. Przedstawione w pracy urządzenie przeznaczone jest do sterowanie różnorodnymi odbiornikami energii elektrycznej niemogącymi być bezpośrednio sterowanymi z sieci Ethernet. W pracy przedstawiono przyjęte...
-
Łączenie danych pomiarowych z dodatkową wiedzą metrologiczną w celu oceny niepewności pomiaru
PublicationPrzedstawiono modus operandi w ocenie niepewności pomiaru dla krótkich serii pomiarowych. Metoda wykorzystuje dodatkową wiedzę metrologiczną do zwiększenia liczby stopni swobody rozkładu t-Studenta, uzyskiwanego w wyniku bayesowskiej analizy wyników pomiarów. W rezultacie możliwe jest oszacowanie niepewności standardowych dla najkrótszych serii pomiarowych, o długości n=2 i n=3.
-
UKŁAD I PROGRAM DO WYZNACZANIA PARAMETRÓW SCHEMATU ZASTĘPCZEGO SUPERKONDENSATORA
PublicationW pracy przedstawiono prototyp urządzenia do wyznaczania parametrów schematu zastępczego superkondensatora na podstawie jego charakterystyk ładowania i rozładowania. Urządzenie składa się ze sterowanego źródła prądowego do ładowania i rozładowywania superkondensatora, przetwornika analogowo-cyfrowego do pomiaru prądu i napięcia w trakcie eksperymentu oraz mikroprocesora do sterowania pomiarem i komunikacji z komputerem na którym...
-
Wpływ źródeł oświetlenia LED na pogorszenie niektórych parametrów energii elektrycznej
PublicationW artykule przedstawiono częściowe wyniki pomiarów mocy w nowo powstałym obiekcie przeznaczonym pod działalność naukowo badawczą oraz biurową. Obiekt ten charakteryzował się znacznym wykorzystaniem tanich opraw oświetleniowych LED. Dodatkowo w izolowanej sieci zasilania wykonano badania dostępnych komercyjnie układów oświetleniowych LED dla przypadku zasilania ich napięciem odkształconym. Wykonane pomiary i badania wskazują na...
-
Applications of Raman spectroscopy for detection of selected substances in tissues
PublicationThis dissertation explores the applications of Raman spectroscopy for biological tissue analysis. Basics of Raman and surface-enhanced Raman spectroscopy (SERS) are described, along with an analysis of the literature on biodetection and non-invasive blood analysis with emphasis on glucose detection. Instrumentation for Raman measurements is described. The sources of noise and interferences occurring in biological tissue measurements...