Didn't find any results in this catalog!
But we have some results in other catalogs.Search results for: NON-DESTRUCTIVE CORROSION MONITORING
-
Characterization of corrosion in reinforced concrete beams using destructive and non-destructive tests
PublicationThe paper presents both non-destructive and destructive experimental tests on steel-reinforced concrete beams subjected to electrochemical corrosion. To examine the condition and behavior of the specimens, destructive tests were carried out, i.e., a three-point bending together with a modulated ultrasonic wave test. In addition, a series of non-destructive experiments were conducted, such as the potential measurement method, low-frequency...
-
Non-destructive inspection of anti-corrosion protective coatings using optical coherent tomography
PublicationW artykule przedstawiono zastosowanie optycznej tomografii koherentnej (OCT) do badania antykorozyjnych powłok ochronnych. Omówiono właściwości optycznej interferometrii niskokoherentnej jako zastosowanej metody pomiarowej, opisano budowę pomiarowego systemu OCT, zbudowanego w Katedrze Metrologii i Optoelektroniki WETI PG. Przy pomocy zrealizowanego systemu przebadano grupę powierzchni metalicznych pokrytych różnymi powłokami antykorozyjnymi....
-
A study on microcrack monitoring in concrete: discrete element method simulations of acoustic emission for non-destructive diagnostics
PublicationThe research is focused on the monitoring of fracture evolution in concrete beams under three-point bending using the acoustic emission technique and the discrete element method. The main objective of the study was to numerically and experimentally investigate the mechanism behind the generation of elastic waves during acoustic emission events and their interaction with micro- and macro-cracking in concrete beams under monotonic...
-
Corrosion monitoring by harmonic analysis in aqueous environments
PublicationThis paper presents tests concerning the rate of corrosion in non-alloy steel (type S235JR) in an aqueous environment, with an additive of sodium chloride by means of polarization resistance measurements and harmonic analysis. The tests have been carried out for steel samples exposed to the testing environment for six weeks, in order to obtain a constant rate of corrosion in the function of time. The measurements have aimed at...
-
Application of Galvanostatic Non-Linear Impedance Spectroscopy to the Analysis of Metallic Material Degradation
PublicationThis study presents a novel application of Non-Linear Electrochemical Impedance Spectroscopy (NLEIS) in galvanostatic mode for the rapid, non-destructive assessment of metal degradation. By using galvanostatic mode instead of traditional potentiostatic methods, polarization-related challenges are mitigated, enabling more accurate and reliable analysis. The technique allows for the determination of corrosion rates (corrosion current)...
-
Corrosion Monitoring in Petroleum Installations—Practical Analysis of the Methods
PublicationThis paper presents the most typical corrosion mechanisms occurring in the petroleum industry. The methods of corrosion monitoring are described for particular corrosion mechanisms. The field and scope of the application of given corrosion-monitoring methods are provided in detail. The main advantages and disadvantages of particular methods are highlighted. Measurement difficulties and obstacles are identified and widely discussed...
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
PublicationThis paper presents an implementation of the monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in a utility water installation using an automated corrosion monitoring system. Due to the fact that the corrosion inhibitor was added to water intended for human consumption, it was necessary to build a multi-sensor monitoring system. In order to implement corrosion monitoring using a linear...
-
Corrosion process monitoring by AFM higher harmonic imaging
PublicationThe atomic force microscope (AFM) was invented in 1986 as an alternative to the scanning tunnelling microscope, which cannot be used in studies of non-conductive materials. Today the AFM is a powerful, versatile and fundamental tool for visualizing and studying the morphology of material surfaces. Moreover, additional information for some materials can be recovered by analysing the AFM's higher cantilever modes when the cantilever...
-
Monitoring of underdeck corrosion by using acoustic emission method
PublicationThis paper presents first short characteristics of underdeck corrosion process as well as a problem of its monitoring. Next is described an acoustic emission (AE) method elaborated by Department of Ship Technology , Quality Systems and Material Engineering, Gdańsk University of Technology in cooperation with partners of CORFAT project realized within 7th EU Frame Program . Further are presented short characteristics of the emission...
-
Corrosion monitoring as a factor increasing the safety of hydrotechnical infrastructure
PublicationWater distribution systems at KGHM S.A. are of great importance for the efficient production of copper and environmental protection. For failures leading to perforation and leakage, the corrosion processes are responsible. This paper aims to assess corrosion on the basis of the analysis of the exposure of the Hydrotechnical Plant pipelines. To this end, the system of transfer and deposition of post-flotation waste as well as the...