Didn't find any results in this catalog!
But we have some results in other catalogs.Filters
total: 8235
-
Catalog
- Publications 7265 available results
- Journals 196 available results
- Conferences 13 available results
- Publishing Houses 2 available results
- People 124 available results
- Inventions 1 available results
- Projects 16 available results
- Research Equipment 8 available results
- e-Learning Courses 129 available results
- Events 33 available results
- Open Research Data 448 available results
displaying 1000 best results Help
Search results for: OPEN KNEE MODEL
-
Determination of selected parameters in a 1D open channel flow model
PublicationOkreślenie parametrów jest ważnym etapem tworzenia modelu matematycznego. W przypadku jednowymiarowego modelu przepływu ze swobodną powierzchnią opisanego układem równań de Saint-Venanta, jedną z grup parametrów wymagających identyfikacji są parametry związane z tarciem. Mogą one być określone w różny sposób, ale w większości przypadków problem ten stanowi zagadnienie żle postawione. W takich przypadkach najczęściej stosowaną...
-
3D intact knee model used in analysis of the medial meniscus biomechanics in the osteoarthritic knee joint - input text file for computation
Open Research DataThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model with original geometry and material parametetrs was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. The file was created in Abaqus 6.14-2, but can be read in a text editor.
-
Concept of implementation of open water model tests for assessment of safety of ships in damaged conditions
PublicationPraca zawiera opis koncepcji zastosowania badań modelowych na wodach otwartych w odniesieniu do oceny bezpieczeństwa statków w stanie uszkodzonym. Badania modelowe w omawianym zakresie mogą stanowić alternatywną metodę oceny bezpieczeństwa statków w stanie uszkodzonym lub mogę służyć do weryfikacji oceny bezpieczeństwa statków w stanie uszkodzonym, przeprowadzonej za pomocą metody zawartej w zharmonizowanej wersji konwencji SOLAS...
-
An Adversarial Machine Learning Approach on Securing Large Language Model with Vigil, an Open-Source Initiative
PublicationSeveral security concerns and efforts to breach system security and prompt safety concerns have been brought to light as a result of the expanding use of LLMs. These vulnerabilities are evident and LLM models have been showing many signs of hallucination, repetitive content generation, and biases, which makes them vulnerable to malicious prompts that raise substantial concerns in regard to the dependability and efficiency of such...
-
3D knee model G with reduced thickness of articular cartilage - input text file for computation
Open Research DataThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the model G articular cartilage thickness was reduced in specific areas to simulate degenerative changes in the medial knee osteoarthritis. The file was...
-
A subdomain model for armature reaction field and open‐circuit field prediction in consequent pole permanent magnet machines
PublicationIn this paper, the machine quantity, such as electromagnetic torque, self and mutual inductances, and electromotive force, is analytically calculated for non-overlapping winding consequent pole slotted machine for open-circuit field and armature reaction. The sub-domain approach of (2-D) analytical model is developed using Maxwell's equations and divide the problem into slots, slot-openings, airgap and magnets region, the magnet...
-
Application of Open-Hardware-Based Solutions for Rapid Transition From Stationary to the Remote Teaching Model During Pandemic
PublicationWhile research indicates usefulness of remote laboratories in teaching of digital hardware systems, their main application is to complement stationary classes. This work presents a low-cost, scalable architecture that supports rapid transformation of teaching to a model based solely on remote access mechanisms. Background: Adaptation of online laboratory solutions from the literature to en-masse teaching of digital circuits is...
-
3D knee model M with decreased material parameters of the cartilage and menisci - input text file for computation
Open Research DataThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the model M the material parameters of cartilage and menisci were reduced to simulate degenerative changes in the medial knee osteoarthritis. The file...
-
3D model of osteoarthritic (OA) knee joint for analysis of the medial meniscus biomechanics - input text file for computation
Open Research DataThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the OA model thickness of articular cartilage and material parameters of the cartilage and menisci were reduced to simulate degenerative changes in the...
-
Two-dimensional vertical Reynolds-averaged naviers-stokes equations versus one-dimensional Saint-Venant model for rapidly varied open channel water flow modelling
PublicationPrzedstawiono dwa modele przepływu wody ze swobodną powierzchnią -płaski pionowy model Reynoldsa i model de Saint-Venanta.Do rozwiązania równań pierwszego modelu zastosowano schemat SIMPLE oraz wykorzystano metodę cząstek znaczonych MAC do wyznaczania swobodnej powierzchni wody. Równania Saint-Venanta rozwiązano metodą objętości skończonych. Obydwa modele zastosowano do symulacj zjawiska typu katastrofa zapory. Porównano wyniki...