Symmetrical power line conditioner - basic properties
PublicationIn this paper the basis of analytical modelling of the UPQC arrangements (Unified Power Quality Conditioner) in d-q rotating coordinates, as well as select results of investigations conducted on the simplified small power laboratory model, were talked over. In short form power balance as well as fundamental dependences and analytical model with regard of decoupling circuits, were investigated. Applied method for DC link capacitance...
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublicationThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
Active Power Quality Controllers
PublicationDynamic Static Synchronous Compensator is the most important controller for distribution networks and probably in SEEN. It has been widely used since the 1990s to regulate system voltage precisely, improve voltage profile, reduce voltage harmonics, reduce transient voltage disturbances and load compensation. Rather than using conventional capacitors and inductors combined with fast switches, the D-STATCOM uses a power-electronics...
-
High power, medium voltage, modular active power filtering system
Publication -
A simple modular active power electronic transformer
Publication -
A boost topology active power factor corrector.
PublicationPrzedstawiono układ analogowego aktywnego korektora zbudowanego na układzie scalonym kontrolera PWM oraz tranzystorem MOS jako okresowo przełączonym kluczem. Układ korektora zapewnia pobór prądu z sieci energetycznej w postaci przebiegu prawie sinusoidalnego o małych zniekształceniach i w fazie z sinusoidalnym napięciem sieci.
-
A novel approach to energy safety improvement in the marine power plants with active power surge compensator
PublicationPaper raises a point of power surges and theirs adverse effects in the marine power plants. The article explains a source of surges appearance, and presents measurements carried out on a modern ship. It discusses effects of dynamic power transients on the ship’s energy safety. Finally it proposes, a novel approach for power surge elimination, based on medium voltage active conditioner. As well as it propose the topology and control...
-
Design of a simple modular active power electronic transformer
Publication -
Predictive control system of the shunt active power filter
Publication -
New control system of the shunt active power filter
Publication -
High power, zero ripples active filtering system with power modules operating in parallel
Publication -
A filter bank solution for active power filter control algorithms
PublicationThb paper describes the proposed active power fiIter (APF) with a new control circuit based on an algorithm using ufilter bank and a harmonic predictor. The conirol circuit was realized using the digiiaI signor processor ADSP-21065L and FPGA circuiL In the proposed circuit transient performunee of APF is improved The active power fdter circuil has been built and teste6 and some illustrative, experimental results are uIso presented...
-
Design and evaluation of a base module of active power electronic transformer
PublicationThis paper presents an active power electronic transformer (APET) based on modular structure. The proposed three phase APET consists of at least three base modules (BM). The input/output stage of the BM is based on half-bridge sub modules. The isolation stage includes a medium frequency transformer and is realized as a dual half-bridge. The paper describes construction process and explains the control strategy. The theoretical...
-
Compensation of Dead Time Effects for Shunt Active Power Filters
PublicationThe paper presents a comprehensive approach to the compensation of the grid current distortion for shunt active power filter systems. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the estimation of compensating currents and grid voltages, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Design and evaluation of a base module of active power electronic transformer
Publication -
A Special Multi-Pulse Converter with Small Active Power Filter
Publication -
Comprehensive compensation of grid current distortion by shunt active power filters
PublicationThe paper presents a comprehensive approach to the compensation of grid current distortion in shunt active power filter systems. Four sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Single-phase power electronics transformer with active functions for smart grid
PublicationThis paper presents the control of one cell of a modular single-phase power electronics transformer with active functions for meeting the smart grid concept. In this way, the converter could be used not only as a conventional transformer but also for grid such as reactive power, harmonic elimination and energy storage. The topology of the cell is composed by a bidirectional converter with three stages: a half bridge in the input...
-
Single-phase power electronics transformer with active functions for smart grid
Publication -
Experimental tests results of the diode rectifier with series active power filter
Publication -
Balancing energy consumption in limited power grid with active front-end and three phase dual active bridge system
PublicationPaper deals with simulation analysis of bidirectional power converters system for charging station of electric vehicle in condition of limited power source in city infrastructure. In case of incapability to provide additional power supply through the grid by virtue of historical, architectural and economic reasons it is possible to solve this issue by implementation of mobile battery-powered supply source. The proposed bidirectional...
-
A diode rectifier with a Special Coupled Reactor and additional Active Power Filter in the Marine Local Power Network Supply Conditions
Publication -
A new method of wind farm active power curve estimation based on statistical approach
PublicationThe purpose of this paper is to solve the wind farm active power estimation problem, introducing the method which is based on a statistical approach and robust fitting. The proposed algorithm uses a statistical approach and compared to existing ones- includes a wind direction as well as the influence of turbine start-up procedure on the estimation. The results show that additional estimation inputs i.e. the wind direction and the...
-
A hybrid, coupled reactors based 18-pulse diode rectifier with active power filter
Publication -
The use of a static electrical energy meter as a transducer of active power to a pulse frequency signal
Publication -
Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
PublicationThis paper presents the compensation tasks performed by a shunt active power filter, including compensation of harmonic currents, reactive power, and an unbalanced load current. The paper demonstrates novel control of the shunt active power filter in a closed-loop system. The control algorithm was verified by performing simulations and compared the simulated results with those obtained in an open-loop control system. All simulations...
-
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublicationThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
The impact of the distribution network reconfiguration on active power losses: Selected issues of UPGRID project realization
PublicationThe dynamic development of smart grids allows the use of remote controllable switches to change the configuration of the distribution network. The paper discusses the impact of the distribution system reconfiguration on active power losses, taking into account the typical daily load profiles. Based on modified IEEE 33-bus test distribution system the article presents the method of selection the appropriate sensitivity factor and...
-
Stability Analysis of Shunt Active Power Filter with Predictive Closed-Loop Control of Supply Current
PublicationThis paper presents a shunt active power filter connected to the grid via an LCL coupling circuit with implemented closed‐loop control. The proposed control system allows selective harmonic currents compensation up to the 50th harmonic with the utilization of a model‐based predictive current controller. As the system is fully predictive, it provides high effectiveness of the harmonic reduction, which is proved by waveforms achieved...
-
Analytical Estimation of Power Losses in a Dual Active Bridge Converter Controlled with a Single-Phase Shift Switching Scheme
PublicationMicro-grid solutions around the world rely on the operation of DC/DC power conver- sion systems. The most commonly used solution for these topologies is the use of a dual active bridge (DAB) converter. Increasing the efficiency and reliability of this system contributes to the improvement in the stability of the entire microgrid. This paper discussed an analytical method of energy efficiency and power loss estimation in a single...
-
Suppression of Supply Current Harmonics of 18-Pulse Diode Rectifier by Series Active Power Filter with LC Coupling
PublicationThe reported research aims at improving the quality of three-phase rectifier supply currents. An effective method consists of adding properly formed booster voltages to the fundamental supply voltages using a series active filter. In the proposed solution, the booster voltages are generated by three single-phase systems consisting of inverters, LC filters, and single-phase transformers. The application of LC couplings ensures low...
-
A multi-pulse diode rectifier with a coupled three-phase reactor and additional small shunt active power filter
Publication -
Supply system based on the 18-pulse diode rectifier with coupled reactors and integrated with the series active power filter
Publication -
СИЛОВОЙ ПРЕОБРАЗОВАТЕЛЬ С АКТИВНЫМ ПОДАВЛЕНИЕМ ВЫСШИХ ГАРМОНИК ДЛЯ СИСТЕМ ЭЛЕКТРОСНАБЖЕНИЯ ЛЕТАТЕЛЬНЫХ АППАРАТОВ (Power converter with active suppression of higher harmonics for aircraft power supply systems)
PublicationПредставлены два алгоритма активной фильтрации для силового преобразователя с активным подавлением высших гармоник. Первый алгоритм основан на дискретном преобразовании Фурье: посредством синтезированной системы управления инвертированные измеренные высшие гармоники напряжения поступают на вход инвертора. Второй метод управления основан на алгоритме с использованием принципов самообучения, что значительно снижает потребность в...
-
Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
PublicationThe paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18-pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism...
-
Power Surge Compensator based on a Four Level Diode Clamped Inverter for ship application. Average model
PublicationPaper presents continuous average value model of Power Surge Compensator based on a Four Level Diode Clamped Inverter with super capacitor as a energy storage device. This conditioner is design for power surge or fluctuation elimination, by compensating it with energy stored in ESD. Continuous average value model of multilevel S-PWM has been presented also. Summary of raised problem is a simulation model made in PowerSim Psim 8...
-
Modeling and experimental investigation of the small UPQC systems
PublicationIn this paper the basis of analytical modelling of the UPQC arrangements (Unified Power Quality Conditioner) in d-q rotating coordinates, as well as select results of investigations conducted on the simplified small power laboratory model were talked over. In short form power balance as well as fundamental dependences and analytic model with regard of decoupling circuits were investigated. Applied method for DC link capacity selection...
-
Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę
PublicationPoniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.
-
Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym
PublicationZnanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy....
-
Wieloobszarowa regulacja systemu turbogeneratora elektrowni jądrowej =Multiregional control of nuclear power plant turbogenerator system
PublicationW artykule przedstawiono propozycję zaawansowanej struktury sterowania układem turbogeneratora w szerokim zakresie zmian zapotrzebowania na moc czynną. Dla potrzeb syntezy tej struktury wykorzystano nieliniowe, dynamiczne modele turbiny parowej i generatora synchronicznego współpracującego z systemem elektroenergetycznym. Zaproponowane algorytmy sterowania oparte są odpowiednio o wieloobszarowe regulatory rozmyte, z lokalnymi regulatorami...
-
Porównanie działania transformatora symetryzującego (zygzak) z aktywnym energoelektronicznym symetryzatorem prądów fazowych linii niskiego napięcia
PublicationNa potrzeby planowania sieci niskiego napięcia operatorzy systemów dystrybucyjnych (OSD) zakładają symetryczne warunki obciążenia linii. Z roku na rok, rośnie liczba rozproszonych systemów fotowoltaicznych (PV) zainstalowanych w sieciach niskiego napięcia, których większość to małe jednofazowe systemy dachowe. Dodatkowo, do niesymetrii obciążenia przyczyniają się instalowane masowo pompy ciepła i ładowane jednofazowo samochody...
-
Problemy przyłączania farm wiatrowych do systemu elektroenergetycznego z wykorzystaniem kabli WN
PublicationArtykuł prezentuje problemy, jakie rodzi przyłączanie farm wiatrowych do systemu elektroenergetycznego za pomocą kabli wysokiego napięcia. Autor wskazuje możliwe problemy z kompensacją mocy biernej, w zależności od sposobu przyłączenia dławika kompensacyjnego i nastawień układów regulacji mocy biernej oraz napięcia farmy wiatrowej. Artykuł porusza też zagadnienia zwiększenia strat mocy czynnej powodowanych instalacją dławików kompensacyjnych.
-
Handlowo-techniczne bilansowanie energii w obszarach sieci dystrybucyjnej
PublicationW artykule omówiono problemy wywołane przez rosnący udział generacji rozproszonej we współczesnych systemach elektroenergetycznych. Przedstawiono nową koncepcję rozwiązywania zagadnienia bilansowania mocy czynnej w obszarach sieci dystrybucyjnych, opartą o wykorzystanie nowych struktur organizacyjnych takich jak: klastry energii, wydzielone systemy dystrybucyjne, spółdzielnie energetyczne, wirtualne elektrownie i grupy bilansujące.
-
Regulacja napięcia w sieci nN z rozproszonymi źródłami energii
PublicationPodłączanie rozproszonych źródeł energii do sieci energetycznych niskiego napięcia powoduje powstawanie problemów zmienności i niesymetrii napięcia, zwłaszcza w przypadku dużych odległości od transformatora zasilającego. W skrajnych przypadkach zachodzi konieczność redukcji mocy generowanej przez źródło podczas oddawaniu energii do sieci. Rozwiązaniem tego problemu jest zastosowanie energoelektronicznego regulatora napięcia składającego...
-
Przegląd systemów ładowania elektrycznych osobowych pojazdów i koncepcja dwukierunkowej ładowarki pokładowej
PublicationAktualnie trwa intensywny rozwój pojazdów elektrycznych (EV) i hybrydowych typu plug-in (PHEV) z pokładowymi bateriami akumulatorów. Badania w tej dziedzinie skupiają się na maksymalizowaniu sprawności oraz minimalizowaniu masy i objętości systemów ładowania baterii. W artykule przedstawiono podział systemów ładowania osobowych pojazdów typu EV/PHEV. Opisano systemy ładowania przewodowego z podziałem na ładowarki pokładowe i zewnętrzne, systemy...
-
Wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego sterowanego ze sprzężeniem od prądu zasilającego
PublicationW artykule przedstawiono wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego i zdolność kompensacji prądów harmonicznych. Zbadano wpływ opóźnień czasowych wynikających z implementacji cyfrowej sterowania, wpływ impedancji zwarciowej sieci zasilającej oraz błędów generowania napięcia przekształtnika na jakość kompensacji filtru. Badania symulacyjne przeprowadzono dla trzech układów sterowania: otwartego, zamkniętego...
-
Wielopoziomowy przekształtnik trakcyjny SiC z izolacją od sieci 3kV DC realizowaną za pomocą transformatorów 30kHz do napędów EZT
PublicationW referacie przedstawiono wielopoziomowy izolowany kaskadowy przekształtnik DC-AC z tranzystorami SiC MOSFET 1,2kV, przeznaczony do napędów elektrycznych zespołów trakcyjnych (EZT). Zaproponowana konstrukcja przekształtnika, przeznaczonego do pracy przy zasilaniu z sieci trakcyjnej 3kV DC, spełnia założenia energoelektronicznego transformatora trakcyjnego (z ang. Power Electronic Traction Transformer). Budowa modułowa z niskonapięciowych...
-
Predykcyjne sterowanie równoległym filtrem aktywnym ze sprzężeniem od prądu zasilającego
PublicationArtykuł przedstawia nowatorską strategię predykcyjnego sterowania równoległym energetycznym filtrem aktywnym (EFA). Proponowane sterowanie zawiera sprzężenie zwrotne od prądu zasilającego i wiąże zalety sterowania w układzie otwartym oraz zamkniętym – szybkość reakcji na zmianę prądu odbioru i bardzo wysoką skuteczność kompensacji. Wysoka jakość prądu kompensacyjnego wynika również z zastosowania w sterowaniu algorytmów predykcyjnych,...
-
Voltage and Reactive Power Load Flow Optimization in the Power System Using Fuzzy Logic
PublicationThe paper presents issues related to voltage control in the power system. An original method of reactive power flow optimization is considered, which leads to improved voltages in the power system and reduced active power losses. The optimization method is based on a procedure that employs fuzzy logic and is supported by a gradient search algorithm. The method has been implemented in PLANS software and verified.
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublicationW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...