The early failure of the gamma nail and the dynamic hip screw in femurs with a wide medullary canal. A biomechanical study of intertrochanteric fractures
PublicationBackground: Intertrochanteric fractures may occur in a bone with a wide medullary canal that may lead to significant mobility of a intramedullary nail, contrary to an extramedullary device. This study evaluates the Dynamic Hip Screw and the gamma nail in AO 31.A2.1 fractures in these circumstances. Methods: Synthetic femora with canals drilled to 18 mm were used. Five fixation types were examined: a 2 - hole and a 4 – hole Dynamic...
-
Circular saw vibrations or dynamics of the spindle
PublicationSawing of wood with circular saws is a typical example of cutting with multi-blade tools. In that kind of cutting, theposition accuracy of following tool blades is a crucial factor which affects the cutting process and machining final effects.Position tooth errors may cause deterioration in cutting conditions, changes in loads of individual teeth and the tool as a whole,and also a decrease in accuracy and surface quality after...
-
Large hydrodynamic thrust bearing: Comparison of the calculations and measurements
PublicationHydrodynamic thrust bearings, used to carry axial loads in heavily loaded shafts of water power plants hydro turbines, can reach outer diameters even exceeding 5 m. In such large objects scale effect could be observed. According to this, allowable bearing specific load assuring safe operation of the bearings has to be decreased, which increases thrust bearing dimensions. This effect is caused by excessive thermal deflections of...
-
Influence of electrode geometric arrangement on the operation of narrow circular electrostatic precipitator
PublicationIn this work the influence of electrode geometric arrangement on the operation of a circular electrostatic precipitator (ESP) was investigated using Particle Image Velocimetry (PIV) method. The ESP was a glass circular cylinder (29 mm in diameter, 300 mm long) equipped with a wire discharge electrode and circular-cylinder collecting electrode. The stainless-steel discharge wire electrode (0.23 mm in diameter, 100 mm long) was mounted...
-
Physical and mathematical modelling of implant-fascia system in order to improve laparoscopic repair of ventral hernia
PublicationThis paper describes an investigation of biomechanical behaviour of hernia repair, which is focused on the selection of safe linking of certain type of implant with fascia in laparoscopic operation. The strength of various fixations of the implant to the fascia is analysed. Methods: The research is based on experimental observations of operated hernia model behaviour during a dynamic impulse load corresponding to post-operative...
-
Enhancing Renal Tumor Detection: Leveraging Artificial Neural Networks in Computed Tomography Analysis
PublicationRenal cell carcinoma is one of the most common cancers in Europe, with a total incidence rate of 18.4 cases per 100 000 population. There is currently significant overdiagnosis (11% to 30.9%) at times of planned surgery based on radiological studies. The purpose of this study was to create an artificial neural network (ANN) solution based on computed tomography (CT) images as an additional tool to improve the differentiation of...
-
Load introduction to composite columns revisited—Significance of force allocation and shear connection stiffness
PublicationThe AISC 360-16 Specification recommends that the design shear force between parts of a composite column in the load introduction area shall be calculated based on the force allocation at ultimate limit state. Applicability of this straightforward method to the load levels that usually arise in slender composite columns is questionable, as this capacity-based force allocation is only true when the axial force is equal to the plastic...
-
Modeling and simulation of blood flow under the influence of radioactive materials having slip with MHD and nonlinear mixed convection
PublicationRadioactive materials are widely in industry, nuclear plants and medical treatments. Scientists and workers in these fields are mostly exposed to such materials, and adverse effects on blood and temperature profiles are observed. In this regard, objective of the current study is to model and simulate blood based nanofluid with three very important radioactive materials, named as Uranium dioxide (UO2), Thorium dioxide (ThO2) and...
-
Combined numerical and experimental approach to determine numerical model of abdominal scaffold
PublicationA proper junction of the prosthesis and the abdominal wall is important in successful hernia repair. The number of tacks should be balanced to assure appropriate mesh fixation and not to induce post-operative pain. Numerical simulations help to find this balance. The study is aimed at creating a proper numerical model of a knitted surgical mesh subjected to boundary conditions and load occurring in the abdominal cavity. Continuous,...
-
Different design aspects of an Organic Rankine Cycle turbine for electricity production using a geothermal binary power plant
PublicationIn recent years, pressure has been growing to increase the share of renewable energy sources in electricity generation, which may offer opportunities for the development of geothermal energy in regions that have been so far considered unprofitable in this respect. One such country currently undergoing an energy transition is Poland in which low-temperature geothermal resources are currently used for district heating and recreation...
-
Ring thruster - a preliminary optimisation study
PublicationThe ring thruster is a new type of propeller, for which there is no experimental data to verify analytical design calculations. A significant feature of the ring thruster is the absence of a shaft. Propeller blades are mounted to the ring rotating inside the housing, which has the shape of a nozzle. For this reason the ring thruster is closest, with respect to both the construction and principle of operation, to the Kort nozzle...
-
Magnetic anisotropy and structural flexibility in the f ield-induced single ion magnets [Co{(OPPh2) (EPPh2)N}2], E = S, Se, explored by experimental and computational methods
PublicationDuring the last few years, a large number of mononuclear Co(II) complexes of various coordination geometries have been explored as potential single ion magnets (SIMs). In the work presented herein, the Co(II) S = 3/2 tetrahedral [Co{(OPPh2)(EPPh2)N}2], E = S, Se, complexes (abbreviated as CoO2E2), bearing chalcogenated mixed donor-atom imidodiphosphinato ligands, were studied by both experimental and computational techniques. Specifically,...
-
Contr-rotating eccentric-mass rotors used as exciters of sinusoidal forces applied to elastically supported bodies
PublicationThe work focuses on aspects of multibody dynamics. Investigated object is a mass driven by rotations of an inertial shaker. Resulting vibrational set consists of two counter-rotating identically-unbalanced rotors. Since the mass centres of the rotors do not coincide with the axes of their rotations, significant centrifugal forces arise during rotations. As both rotors are identically unbalanced, the inter-axial force components...
-
INVESTIGATIONS OF THE EMISSION CHARACTERISTICS OF A DUAL-FUEL GAS TURBINE COMBUSTION CHAMBER OPERATING SIMULTANEOUSLY ON LIQUID AND GASEOUS FUELS
PublicationT his study is dedicated to investigations of the working process in a dual-fuel low-emission combustion chamber for a floating vessel’s gas turbine. As the object of the research, a low-emission gas turbine combustion chamber with partial premixing of fuel and air inside the outer and inner radial-axial swirls was chosen. The method of the research is based on the numerical solution of the system of differential...
-
Effects of FSW Tool Plunge Depth on Properties of an Al-Mg-Si Alloy T-Joint: Thermomechanical Modeling and Experimental Evaluation
PublicationOne of the main challenging issues in friction stir welding (FSW) of stiffened structures is maximizing skin and flange mixing. Among the various parameters in FSW that can affect the quality of mixing between skin and flange is tool plunge depth (TPD). In this research, the effects of TPD during FSW of an Al-Mg-Si alloy T-joint are investigated. The computational fluid dynamics (CFD) method can help understand TPD effects on FSW...
-
HYGRO-MAGNETIC VIBRATION OF THE SINGLE-WALLED CARBON NANOTUBE WITH NONLINEAR TEMPERATURE DISTRIBUTION BASED ON A MODIFIED BEAM THEORY AND NONLOCAL STRAIN GRADIENT MODEL
PublicationIn this study, vibration analysis of single-walled carbon nanotube (SWCNT) has been carried out by using a refined beam theory, namely one variable shear deformation beam theory. This approach has one variable lesser than a contractual shear deformation theory such as first-order shear deformation theory (FSDT) and acts like classical beam approach but with considering shear deformations. The SWCNT has been placed in an axial or...
-
RESEARCH OF HYDRAULIC PISTON PUMPS’ START-UP IN LOW AMBIENT TEMPERATURES
PublicationStarting hydraulic pumps in low ambient temperatures may cause: decreased hydraulic-mechanical efficiency, larger vibration of hydraulic installation, faster wear and more frequent damage to the elements of pumps, change of material properties of elements, increase of pressure drop. As a result of increase of resistance of cold oil flow in the suction pipe, large underpressure may be experienced, causing incomplete filling of pump...
-
Cerclage cable augmentation does not increase stability of the fixation of intertrochanteric fractures. A biomechanical study
PublicationBackground: Intertrochanteric fractures with a posteromedial intermediate fragment are unstable because of the loss of medial support. Additional fixation with a cerclage is used in subtrochanteric fractures, but not in intertrochanteric fractures. The aim of this biomechanical study is to evaluate whether cerclage fixation improves stability of intertrochanteric fractures. Hypothesis: Our hypothesis is that the cerclage fixation...