Filters
total: 924
Search results for: PARTIAL NITRIFICATION (PN)
-
Electrochemical impedance spectroscopy measurements - conductivity vs. temperature and conductivity vs. oxygen partial pressure - BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataThe dataset consists of two main catalogs consisting of measurement data: of the electrical conductivity of the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ (BCZYTb) sample as a function of temperature and of the electrical conductivity as a function of oxygen partial pressure (pO2). Measurements as a function of temperature were carried out in dry and wet air (pH2O ~...
-
Oxygen partial pressure and temperature dependence of Gerischer element of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of Gericher element at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C)and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent circuit...
-
Oxygen partial pressure and temperature dependence of series resistance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of series resistance (R) at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Nadzór naukowy związany z realizacja zadania inwestycyjnego pn. ,, Budowa linii tramwajowej wraz z infrastrukturą towarzyszącą w ulicy Nowej Bulońskiej Północnej w Gdańsku w ramach Gdańskiego Projektu Komunikacji Miejskiej - etap IVA". Audyt otwarcia
PublicationCelem opracowania jest weryfikacja projektu wykonawczego obiektów mostowych zaprojektowanych w ramach zadania inwestycyjnego pn. ,,Budowa linii tramwajowej wraz z infrastrukturą towarzyszącą w ulicy Nowej Bulońskiej Północnej w Gdańsku w ramach Gdańskiego Projektu Komunikacji Miejskiej - etap IVA" (audyt otwarcia). Zakres opracowania obejmuje: • ogólny przegląd dokumentacji, • analizę statyczno–wytrzymałościową mostu, • analizę...
-
Partial-Body Irradiation in Patients with Prostate Cancer Treated with IMRT Has Little Effect on the Composition of Serum Proteome
Publication -
Regarding to functional outcomes after extracapsular dissection with partial facial nerve dissection for small and large parotid neoplasms
Publication -
Limiting partial molar volumes and expansibilities of ammonium perchlorate, tetraalkylammonium perchlorates, and tetrabutylammonium tetraphenylborate in N,N-dimethylformamide
PublicationWyniki pomiarów gęstości i szybkości rozchodzenia się dźwięku w roztworach nadchloranu amonu, nadchloranów alkiloamoniowych i tetrafenyloboranu tetrabutylomoniowego w N,N-dimetyloformamidzie wyznaczono wartości graniczne cząstkowych molowych objętości i rozszerzalności. Dokonano rozdziału tych wartości na udziały jonowe. Przeanalizowano wpływ temperatury oraz długości łańcucha na te wielkości.
-
Oxygen partial pressure and temperature dependence of series resistance of symmetrical porous SrTi0.30Fe0.70O3 electrode on CGO substrate
Open Research DataThis dataset contains values of equivalent circuit element series resistance at different temperatures (800 °C, 700 °C, 600 °C and 500 °C) and oxygen partial pressures (100%, 80%, 50% 30%, 20%, 15%, 10%, 5%, 2.5%, 1%, and 0.3% pO2) of symmetrical SrTi0.30Fe0.70O3 electrode sintered at 800 °C. This values were obtained by fitting each measured impedance...
-
Badania odporności warystorów z wykorzystaniem wymagań pomiarowych zawartych w normie PN EN 61000-4-5
PublicationBadania odporności w EN 61000-4-5 są jednymi z podstawowych badań wykonywanych w ramach testów EMC na portach wejścia wyjścia urządzeń elektronicznych. W referacie przedstawiono uproszczoną metodykę doboru warystorów stanowiących zazwyczaj jeden z elementów ochronnych stosowanych na badanych portach. Proponowana metoda doboru powinny być wykonywana przez projektanta/konstruktora na początku procesu projektowego danego urządzenia....
-
OPINIA TECHNICZNA nr 2/PG Sprawowanie nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską” Przegląd literatury i rozwiązań dot. zastosowania geotub
PublicationOpinię przygotowano w ramach prowadzonego nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską”.
-
Oxygen partial pressure and temperature dependence of low frequency capacitance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of low frequency capacitance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of middle frequency capacitance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of middle frequency capacitance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of low frequency resistance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of low frequency resistance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of middle frequency resistance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of middle frequency resistance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
OPINIA TECHNICZNA nr 4/PG Sprawowanie nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską” Rzeczywiste przykłady falochronów z wykorzystaniem geotub oraz zalecenia do projektowania
PublicationOpinię przygotowano w ramach prowadzonego nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską”.
-
Removal of ammonia nitrogen from groundwater during nitrification processes using pressure filters = Usuwanie azotu amonowego z wód podziemnych w procesie nitryfikacji na filtrach ciśnieniowych
PublicationW pracy zaprezentowano wyniki badań w skali ułamkowo technicznej nad wpływem podwyższonego i zmiennego ciśnienia (do 0,4 MPa) na przebieg usuwania amoniaku z wód podziemnych, w procesie nitryfikacji, w złożu filtracyjnym. Ustalono, że wszystkie filtry badawcze, zarówno ciśnieniowe jak i grawitacyjny, wymagały adaptacji do zmienionego składu filtrowanej wody. Okres adaptacji filtrów ciśnieniowych był dłuższy, niż dla filtra grawitacyjnego....
-
Area specific resistance (at 800 °C - 500 °C) of the SrTi0.30Fe0.70O3 porous oxygen electrodes at different oxygen partial pressures
Open Research DataIn this dataset are presented results of the polarization resistance of SrTi0.30Fe0.70O3 porous oxygen electrodes sintered at 800 °C. The measurement temperature range was between 800 °C and 500 °C. Applied different oxygen partial pressure flow was: 1%, 20% and 100% pO2. Results converted to electrode surfaces area and dived by two electrodes. All...
-
Oxygen partial pressure and temperature dependence of R-CPE1 resistance of symmetrical porous SrTi0.30Fe0.70O3 electrode on CGO substrate
Open Research DataThis dataset contains values of equivalent circuit element R-CPE1 resistance at different temperatures (800 °C, 700 °C, 600 °C and 500 °C) and oxygen partial pressures (100%, 80%, 50% 30%, 20%, 15%, 10%, 5%, 2.5%, 1%, and 0.3% pO2) of symmetrical SrTi0.30Fe0.70O3 electrode sintered at 800 °C. This values were obtained by fitting each measured impedance...
-
Oxygen partial pressure and temperature dependence of R-CPE2 frequency of symmetrical porous SrTi0.30Fe0.70O3 electrode on CGO substrate
Open Research DataThis dataset contains values of equivalent circuit element R-CPE2 frequency at different temperatures (800 °C, 700 °C, 600 °C and 500 °C) and oxygen partial pressures (100%, 80%, 50% 30%, 20%, 15%, 10%, 5%, 2.5%, 1%, and 0.3% pO2) of symmetrical SrTi0.30Fe0.70O3 electrode sintered at 800 °C. This values were obtained by fitting each measured impedance...
-
Oxygen partial pressure and temperature dependence of R-CPE1 capacity of symmetrical porous SrTi0.30Fe0.70O3 electrode on CGO substrate
Open Research DataThis dataset contains values of equivalent circuit element R-CPE1 capacity at different temperatures (800 °C, 700 °C, 600 °C and 500 °C) and oxygen partial pressures (100%, 80%, 50% 30%, 20%, 15%, 10%, 5%, 2.5%, 1%, and 0.3% pO2) of symmetrical SrTi0.30Fe0.70O3 electrode sintered at 800 °C. This values were obtained by fitting each measured impedance...
-
Oxygen partial pressure and temperature dependence of R-CPE1 frequency of symmetrical porous SrTi0.30Fe0.70O3 electrode on CGO substrate
Open Research DataThis dataset contains values of equivalent circuit element R-CPE1 frequency at different temperatures (800 °C, 700 °C, 600 °C and 500 °C) and oxygen partial pressures (100%, 80%, 50% 30%, 20%, 15%, 10%, 5%, 2.5%, 1%, and 0.3% pO2) of symmetrical SrTi0.30Fe0.70O3 electrode sintered at 800 °C. This values were obtained by fitting each measured impedance...
-
Oxygen partial pressure and temperature dependence of R-CPE2 resistance of symmetrical porous SrTi0.30Fe0.70O3 electrode on CGO substrate
Open Research DataThis dataset contains values of equivalent circuit element R-CPE2 resistance at different temperatures (800 °C, 700 °C, 600 °C and 500 °C) and oxygen partial pressures (100%, 80%, 50% 30%, 20%, 15%, 10%, 5%, 2.5%, 1%, and 0.3% pO2) of symmetrical SrTi0.30Fe0.70O3 electrode sintered at 800 °C. This values were obtained by fitting each measured impedance...
-
Oxygen partial pressure and temperature dependence of R-CPE2 capacity of symmetrical porous SrTi0.30Fe0.70O3 electrode on CGO substrate
Open Research DataThis dataset contains values of equivalent circuit element R-CPE2 capacity at different temperatures (800 °C, 700 °C, 600 °C and 500 °C) and oxygen partial pressures (100%, 80%, 50% 30%, 20%, 15%, 10%, 5%, 2.5%, 1%, and 0.3% pO2) of symmetrical SrTi0.30Fe0.70O3 electrode sintered at 800 °C. This values were obtained by fitting each measured impedance...
-
Evaluation of a neurotherapy program for a child with ADHD with Benign Partial Epilepsy with Rolandic Spikes (BPERS) using event-related potentials
Publication -
Partial inhibition of borohydride hydrolysis using porous activated carbon as an effective method to improve the electrocatalytic activity of the DBFC anode
Publication -
Polyethylene Terephthalate Wastes as a Partial Replacement for Fine Aggregates in Concrete Mix, Case of Jimma Town, South West Ethiopia
Publication -
Partial inhibition of borohydride hydrolysis using porous activated carbon as an effective method to improve the electrocatalytic activity of the DBFC anode
PublicationCarbon materials are commonly used catalyst supports in various types of fuel cells. Due to the possibility of designing their properties, they seem to be attractive and functional additives. In Direct Borohydride Fuel Cells (DBFCs), the electrooxidation reaction of borohydride competes with the undesirable hydrolysis reaction, therefore our work aimed to modify anodes based on a multi-component hydrogen storage alloy with a small...
-
Assessment of heat stress in a hot environment using the WBGTeff index according to the standard PN-EN ISO 7243:2018-01
Publication -
Elgold partial: Automotive blogs
Open Research DataThe dataset contains 34 English texts scrapped from automotive blogs. In each text, the named entities are marked. Each name entity is linked to the corresponding Wikipedia if possible. All entities were manually verified by at least three people, which makes the dataset a high-quality gold standard for the evaluation of named entity recognition and...
-
Elgold partial: Movie reviews
Open Research DataThe dataset contains 37 English texts with movie reviews. In each text, the named entities are marked. Each name entity is linked to the corresponding Wikipedia if possible. All entities were manually verified by at least three people, which makes the dataset a high-quality gold standard for the evaluation of named entity recognition and linking algorithms.
-
Elgold partial: Job offers
Open Research DataThe dataset contains 34 English texts scrapped from the web portals offering job offers. In each text, the named entities are marked. Each name entity is linked to the corresponding Wikipedia if possible. All entities were manually verified by at least three people, which makes the dataset a high-quality gold standard for the evaluation of named entity...
-
Elgold partial: History blogs
Open Research DataThe dataset contains 13 texts from English history blogs. In each text, the named entities are marked. Each name entity is linked to the corresponding Wikipedia if possible. All entities were manually verified by at least three people, which makes the dataset a high-quality gold standard for the evaluation of named entity recognition and linking algorithms.
-
OPINIA TECHNICZNA nr 1/PG Sprawowanie nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską” Opinia nt. rozwiązań technicznych przedstawionych w koncepcji przekopu w lokalizacji Nowy Świat
PublicationOpinię przygotowano w ramach prowadzonego nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską”.
-
A Salp-Swarm Optimization based MPPT technique for harvesting maximum energy from PV systems under partial shading conditions
Publication -
System zarzązania bezpieczeństwem i higieną pracy wg. PN-N-18001:2004 na przykładzie stoczni jachtowej w Gdańsku
PublicationOpisano model zarządzania bezpieczeństwem pracy w stoczni jachtowej w Gdańsku.
-
Maksymalny stopień zbrojenia poprzecznego elementów żelbetowych wg zasad wymiarowania przyjętych w EC:2002, DIN:2001, PN:2002.
PublicationW pracy przedstawiono problematykę maksymalnego stopnia zbrojenia na ścinanie elementów żelbetowych, pokazaną na tle wymagań normowych europejskich oraz niemieckich i polskich. Uzyskane wyniki porównano z danymi eksperymentalnymi.
-
Selection of the lambda parameter for DRT analysis of SrTi0.30Fe0.70O3-d oxygen electrode at 800 °C and 1% oxygen partial pressure
Open Research DataThis dataset contains results of selection of the lambda parameter for Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 800 °C and 1% of oxygen partial pressure. Used lambdas: 5 x 10^(-3), 1 x 10^(-3), 5 x 10^(-4) and 1 x 10^(-4)....
-
OPINIA TECHNICZNA nr 5/PG/drogi Sprawowanie nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską” Opinia nt. rozwiązań technicznych przedstawionych w projekcie wykonawczym przekopu w lokalizacji Nowy Świat- branża drogowa
PublicationOpinię przygotowano w ramach prowadzonego nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską”.
-
OPINIA TECHNICZNA nr 5/PG/hydrotechnika Sprawowanie nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską” Opinia nt. rozwiązań technicznych przedstawionych w projekcie wykonawczym przekopu w lokalizacji Nowy Świat -branża hydrotechniczna
PublicationOpinię przygotowano w ramach prowadzonego nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską”.
-
OPINIA TECHNICZNA nr 5/PG/mosty Sprawowanie nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską” Opinia nt. rozwiązań technicznych przedstawionych w projekcie wykonawczym przekopu w lokalizacji Nowy Świat - branża mostowa
PublicationOpinię przygotowano w ramach prowadzonego nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską”.
-
OPINIA TECHNICZNA nr 3/PG/drogi Sprawowanie nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską” Opinia nt. rozwiązań technicznych przedstawionych w projekcie budowlanym przekopu w lokalizacji Nowy Świat - branża drogowa
PublicationOpinię przygotowano w ramach prowadzonego nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską”.
-
OPINIA TECHNICZNA nr 3/PG/hydrotechnika Sprawowanie nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską” Opinia nt. rozwiązań technicznych przedstawionych w projekcie budowlanym przekopu w lokalizacji Nowy Świat - branża hydrotechniczna
PublicationOpinię przygotowano w ramach prowadzonego nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską”.
-
OPINIA TECHNICZNA nr 3/PG/mosty Sprawowanie nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską” Opinia nt. rozwiązań technicznych przedstawionych w projekcie budowlanym przekopu w lokalizacji Nowy Świat - branża mostowa
PublicationOpinię przygotowano w ramach prowadzonego nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską”.
-
A New Phenylalanine Derivative Acts as an Antagonist at the AMPA Receptor GluA2 and Introduces Partial Domain Closure: Synthesis, Resolution, Pharmacology, and Crystal Structure
Publication -
Elgold partial: Scientific papers' abstracts
Open Research DataThe dataset contains 87 Scientific papers' abstracts in English randomly chosen from the folowing scientific disciplines: Biomedicine, Life Sciences, Mathematics, Medicine, Science, Humanities, Social Science.
-
Elgold partial: Amazon product reviews
Open Research DataThe dataset contains 34 Amazon product reviews in English. In each text, the named entities are marked. Each name entity is linked to the corresponding Wikipedia if possible. All entities were manually verified by at least three people, which makes the dataset a high-quality gold standard for the evaluation of named entity recognition and linking algorithms.
-
Bezpieczne wymiarowanie ścinania ze zmiennym kątem THETA w kratownicach zastępczych według norm EC:2003, DIN:2003, PN:2002
PublicationPraca przedstawia zagadnienie wymiarowania elementów żelbetowych na ścinanie według zmodyfikowanej kratownicy Morscha, zamieszczonej w normach: europejskiej, niemieckiej i polskiej. Podano praktyczne wnioski odnośnie bezpiecznego przyjmowania kąta THETA, odwzorowującego nachylenie myślowo wydzielonych betonowych krzyżulców ściskanych.
-
OPINIA TECHNICZNA nr 7/PG/mosty Sprawowanie nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską” Analiza mostu w Nowakowie po modernizacji schematu statycznego w wyniku uwag NN przedstawionych w opinii nr 5/PG/mosty
PublicationOpinię przygotowano w ramach prowadzonego nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską”.
-
OPINIA TECHNICZNA nr 8/PG/mosty Sprawowanie nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską” Opinia uzupełniająca do 5/PG/mosty w zakresie mechanizmów zastosowanych na przekopie po przedstawieniu przez projektanta wyciągu z obliczeń
PublicationOpinię przygotowano w ramach prowadzonego nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską”.
-
OPINIA TECHNICZNA nr 9/PG/hydrotechnika Sprawowanie nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską” Opinia uzupełniająca do 5/PG/hydrotechnika w zakresie obliczeń dot. sztucznej wyspy po uwzględnieniu uwag NN przez projektanta.
PublicationOpinię przygotowano w ramach prowadzonego nadzoru naukowo-technicznego podczas opracowywania projektów obiektów hydrotechnicznych, mostowych i drogowych w ramach realizacji przedsięwzięcia pn. „Budowa drogi wodnej łączącej Zalew Wiślany z Zatoka Gdańską”.