Filters
total: 3356
displaying 1000 best results Help
Search results for: free-text feedback
-
High Performance Tubular Heat Exchanger with Minijet Heat Transfer Enhancement
PublicationIn the paper, the original cylindrical heat exchanger with minijets (MJHE) was introduced. The systematic experimental analysis of the prototype heat exchanger was described with special attention paid to such parameters as the heat transfer effectiveness, heat transfer rates, overall heat transfer coefficients, and pressure drop. The heat transfer coefficients were determined based on Wilson plot method, the most suitable approach...
-
THE DETERMINATION OF ABRASION RESISTANCE OF SELECTED BIOMATERIALS FOR THE FRICTION PAIRS IN THE HIP JOINT ENDOPROSTHESIS
PublicationThe key requirement for the modern endoprosthesis is high durability of the friction components, which results in long and trouble-free operation in the human body. The durability of currently used endoprosthesis is often limited by tribological wear processes of friction components (e.g. between the head and the acetabular component in a hip joint endoprosthesis) [8, 19, 23, 24]. In order to compare the tribological wear, tribological...
-
Strong Monogamies of No-Signaling Violations for Bipartite Correlation Bell Inequalities
PublicationThe phenomenon of monogamy of Bell inequality violations is interesting both from the fundamental perspective as well as in cryptographic applications such as the extraction of randomness and secret bits. In this article, we derive new and stronger monogamy relations for violations of Bell inequalities in general no-signaling theories. These relations are applicable to the class of binary output correlation inequalities known as...
-
Fully enzymatic mediatorless fuel cell with efficient naphthylated carbon nanotube-laccase composite cathodes
PublicationAn efficient, mediator-free enzymatic glucose/O2 biofuel cell with an oxygen intensive anode based on glucose dehydrogenase is presented. In the device,the power of the biofuel cell and electrode potentials of each of the enzymatic electrodes were monitored in parallel under the biofuel cell working conditions. The carbon nanotube composite biocathode demonstrates an almost constant electrode potential vs. saturated calomel electrode...
-
Objectivization of audio-video correlation assessment experiments
PublicationThe purpose of this paper is to present a new method of conducting an audio-visual correlation analysis employing a head-motion-free gaze tracking system. First, a review of related works in the domain of sound and vision correlation is presented. Then assumptions concerning audio-visual scene creation are shortly described. The objectivization process of carrying out correlation tests employing gaze-tracking system is outlined....
-
Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
PublicationThe paper dealt with the issue of breakdowns detection of isolated hanging wires on the medium-voltage transmission. The main aim of article is to describe the function of created breakdowns detector and evaluation its. The breakdowns detector is created based in indicators of faults such as touch between tree limbs and insulated wire, touch tree limbs with several phases or fall insulated wire on the ground. Breakdowns detector...
-
X-ray Photoelectron Spectroscopy studies of laser-induced titania nanotubes
Open Research DataThis dataset contains the results of high-resolution XPS studies obtained during the formation of the hollow nanopillar arrays through the laser-induced transformation of titania nanotubes.
-
Prediction of pile shaft capacity in tension based on some direct CPT methods – Vistula Marshland test site
PublicationThis paper presents different CPT methodologies for the prediction of the pile shaft resistance in tension on the example of three reference screw piles of the Jazowa test site in Poland. The shaft capacity was estimated based on the cone resistance, sleeve friction and CPT excess pore water pressure. Three piles with a diameter of 0.4 m and the length...
-
Creating new voices using normalizing flows
PublicationCreating realistic and natural-sounding synthetic speech remains a big challenge for voice identities unseen during training. As there is growing interest in synthesizing voices of new speakers, here we investigate the ability of normalizing flows in text-to-speech (TTS) and voice conversion (VC) modes to extrapolate from speakers observed during training to create unseen speaker identities. Firstly, we create an approach for TTS...
-
Data Analysis 2023/24
e-Learning CoursesData Analysisdr inż. Karol Flisikowski, prof. PG - winter semester 2023/24
-
COLON, Colon, NOS - Female, 76 - Tissue image [4260730038479541]
Open Research DataThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Programowanie w bioinformatyce - 2023
e-Learning CoursesPodstawowy kurs wykorzystania narzędzi programistycznych do rozwiązywania różnorodnych zadań z obszaru biologii molekularnej. Studenci poznają zarówno niuanse samego języka, jak i specjalistyczne biblioteki pozwalające efektywnie rozwiązywać, zarówno zaawansowane problemy bioinformatyczne, jak i inne zadania jakie napotyka się w praktyce inżynierskiej
-
Technika obliczeniowa i symulacyjna - laboratorium (2023) (89)
e-Learning CoursesKurs dotyczący części laboratoryjnej przedmiotu Technika obliczeniowa i symulacyjna , studia I stopnia na WETI PG, sem. 2, kierunek EiT Prowadzący: dr inż. Piotr Grall (piotr.grall@pg.edu.pl) mgr inż. Mariusz Rudnicki (mariusz.rudnicki@pg.edu.pl) dr inż. Jan Schmidt (jan.schmidt@pg.edu.pl)
-
Programowanie w bioinformatyce - 2024
e-Learning CoursesPodstawowy kurs wykorzystania narzędzi programistycznych do rozwiązywania różnorodnych zadań z obszaru biologii molekularnej. Studenci poznają zarówno niuanse samego języka, jak i specjalistyczne biblioteki pozwalające efektywnie rozwiązywać, zarówno zaawansowane problemy bioinformatyczne, jak i inne zadania jakie napotyka się w praktyce inżynierskiej
-
Power System Stabilizer as a Part of a Generator MPC Adaptive Predictive Control System
PublicationIn this paper, a model predictive controller based on a generator model for prediction purposes is proposed to replace a standard generator controller with a stabilizer of a power system. Such a local controller utilizes an input-output model of the system taking into consideration not only a generator voltage Ug but also an additional, auxiliary signal (e.g., α, Pg, or ωg). This additional piece of information allows for taking...
-
Derivation of motor mean phase currents in PMSM drives operating with low switching-to-fundamental frequency ratio
PublicationPulse width modulation (PWM) of inverter output voltage causes the waveforms of motor phase cur-rents to consist of distinctive ripples. In order to provide suitable feedback for the motor current con-trollers, the mean value must be extracted from the currents’ waveforms in every PWM cycle. A com-mon solution to derive the mean phase currents is to sample their value at the midpoint of a symmetrical PWM cycle. Using an assumption...
-
Application of Smart IoT Technology in Project Management Scenarios
PublicationThe report presents a low-cost and flexible solution to control and monitor home and industrial appliances. The popularity of automation devices has increased greatly in recent years due to higher affordability and simplicity through IoT phone and tablet connectivity. For this purpose, we have developed the IoT Outlet: a stand-alone communication unit, used to connect outlets to the internet. The IoT Plug is a power switch which...
-
Mikrobiologia dla ZT - laboratoria - 2024
e-Learning Courses"Mikrobiologia ogólna dla ZT- wstęp do laboratoriów" jest uzupełnieniem laboratoriów, które będą odbywały się w formie zajęć stacjonarnych. W kursie tym zamieszczone będą informacje, materiały pomocnicze do sprawozdań oraz materiały i dodatkowe instrukcje umożliwiające przygotowanie się do laboratoriów. Prowadzący zajęcia: Zasady zaliczenia: Obecność na zajęciach Sprawdziany Sprawozdania Sprawozdania będą załączane...
-
Lampa nienaftowa - FreeCAD
e-Learning CoursesFreeCAD jest uniwersalnym parametrycznym programem modelującym w przestrzeni 3D CAD, którego rozwój odbywa się wyłącznie według zasad Open Source (licencja LGPL) .FreeCAD jest przeznaczony bezpośrednio dla inżynierii mechanicznej i projektowania detali i produktów, ale mieści się również w szerszym zakresie zastosowań związanych z inżynierią, takich jak architektura, analiza elementów ukończonych, druk 3D i wiele pokrewnych. PS Kurs...
-
Uwierzytelnienie i autoryzacja w systemie STRADAR
PublicationPrzedstawiono rozwiązanie serwera uwierzytelnienia i autoryzacji (AA) w rozproszonym systemie STRADAR, udostępniającym funkcjonalności dla prowadzenia działań operacyjnych Morskiego Oddziału Straży Granicznej. System umożliwia prezentację na stanowisku wizualizacji zdarzeń (SWZ) bieżącej i archiwalnej sytuacji na mapie (AIS, radary), obrazu z kamer, zdjęć, notatek, rozmów telefonicznych oraz plików i wiadomości tekstowych (SMS)...
-
Architekt miasta wczoraj i dziś - wizjoner czy administrator? Uwagi na temat roli architekta miejskiego w kształtowaniu wizji miasta
PublicationArtykuł jest próbą oceny roli architekta miejskiego od początków XX wieku do czasów obecnych. Opracowanie bazuje na pytaniu badawczym, czy we współczesnym mieście wciąż jest miejsc na wizjonerską i wiodącą rolę architekta miejskiego w kształtowaniu przestrzeni, jak to miało miejsce w przeszłości. Architekci miejscy są dziś raczej związani z pełnieniem funkcji administracyjnych, natomiast kwestie przekształceń urbanistycznych powierzane...
-
Tomasz Gzella mgr inż.
People -
Ochrona przed hałasem - 2022-2023
e-Learning CoursesKurs przeznaczony dla studentów I semestru IŚ MGR WILIŚ. Obejmuje wykłady i ćwiczenia/projekty grupowe w zakresie akustyki środowiska, akustyki budowlanej, akustyki instalacyjnej i akustyki architektonicznej pod kątem ochrony przed hałasem. Zapisy na kurs po podziałach na grupy.
-
Simulation of a linear pneumatic actuator with 32 mm piston diameter, 12 mm piston rod diameter and 25 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 63 mm piston diameter, 20 mm piston rod diameter and 100 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 32 mm piston diameter, 14 mm piston rod diameter and 500 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 63 mm piston diameter, 25 mm piston rod diameter and 50 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 63 mm piston diameter, 20 mm piston rod diameter and 200 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 100 mm piston diameter, 25 mm piston rod diameter and 500 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 100 mm piston diameter, 32 mm piston rod diameter and 25 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 63 mm piston diameter, 20 mm piston rod diameter and 500 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 63 mm piston diameter, 20 mm piston rod diameter and 50 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 63 mm piston diameter, 20 mm piston rod diameter and 25 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 63 mm piston diameter, 25 mm piston rod diameter and 200 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 100 mm piston diameter, 25 mm piston rod diameter and 100 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 100 mm piston diameter, 25 mm piston rod diameter and 200 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 32 mm piston diameter, 12 mm piston rod diameter and 50 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 32 mm piston diameter, 14 mm piston rod diameter and 25 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 100 mm piston diameter, 32 mm piston rod diameter and 100 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 100 mm piston diameter, 32 mm piston rod diameter and 500 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 32 mm piston diameter, 14 mm piston rod diameter and 200 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 100 mm piston diameter, 25 mm piston rod diameter and 25 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 63 mm piston diameter, 25 mm piston rod diameter and 500 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 100 mm piston diameter, 25 mm piston rod diameter and 50 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 32 mm piston diameter, 12 mm piston rod diameter and 100 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 100 mm piston diameter, 32 mm piston rod diameter and 50 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 32 mm piston diameter, 14 mm piston rod diameter and 100 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 32 mm piston diameter, 12 mm piston rod diameter and 500 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 100 mm piston diameter, 32 mm piston rod diameter and 200 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...
-
Simulation of a linear pneumatic actuator with 63 mm piston diameter, 25 mm piston rod diameter and 100 mm stroke
Open Research DataThe aim of the simulation was to determine the dynamics of linear pneumatic actuators with different sizes and flow properties. The simulation used the actuator dynamics model as described in [1] and the St Venant - Wantzel's mass flow rate model. The simulation experiment was to calculate the pressure changes in both chambers of the actuator as well...