Search results for: BLOOD PRESSURE, PULSE TRANSIT TIME, APPROXIMATION FORMULAS
-
Blood Pressure - Pulse Transit Time Relationships: Comparative Studies
PublicationA non-invasive and continuous blood pressure estimation could allow a better diagnosis and an earlier detection of various diseases. It could be performed using a photoplethysmography. However, it requires that a relation between blood pressure and pulse transit time is known. Eleven theoretical formulas were used in obtaining the simulated and noise free synthetic data. Then, they were utilized in validation of three, commonly...
-
Can we rely on the pulse transit time - pressure relationship - models comparison
PublicationAn unobtrusive, noninvasive and continuous pressure measurement is invaluable however, still being under research and development. There are many attempts proposing an appropriate relationship between pulse pressure velocity and pressure. Fifteen different formulas, both theoretical and experimental, describing relation between blood pressure and crosssectional area of the vessel were examined. Using these formulas the relation...
-
A Meta-Analysis of Pulse Arrival Time Based Blood Pressure Estimation
PublicationThe paper presents a preliminary meta-analysis of the sample correlation between pulse arrival time (PAT) and blood pressure (BP). The aim of the study was to verify sample correlation coefficient between PAT and BP using an affine model BP = a · P AT + b for systolic and diastolic blood pressure. The databases included in the search were the IEEE Xplore Digital Library, Springer Link and Google Scholar. Only papers from 2005 to...
-
BLOOD PRESSURE
Journals -
Pulse Transit Time - Fiducial Points Accuracy Determination as Examined by Means of Synthetic Signals
PublicationThere are many approaches to non-invasively deter-mine blood pressure. Among them there are methods based on utilizing pulse transit time measured by means of photoplethys-mography. The variability of the blood pressure drop between two measurement sensors placed along the artery and its dependence on the selected parameters describing the cardiovascular system is presented in the paper. This pressure drop modifies the pressure...
-
Continuous blood pressure monitoring by photoplethysmography - signal preprocessing requirements based on blood flow modelling
PublicationObjective. The aim of the study is to investigate the effect of the signal sampling frequency and low-pass filtering on the accuracy of the localisation of the fiducial points of the photoplethysmographic signal (PPG), and thus on the estimation of the blood pressure (i.e. the accuracy of the estimation). Approach. Statistical analysis was performed on 3,799 data samples taken from a publicly available database. Four PPGfiducial...
-
Blood Pressure Estimation Based on Blood Flow, ECG and Respiratory Signals Using Recurrent Neural Networks
PublicationThe estimation of systolic and diastolic blood pressure using artificial neural network is considered in the paper. The blood pressure values are estimated using pulse arrival time, and additionally RR intervals of ECG signal together with respiration signal. A single layer recurrent neural network with hyperbolic tangent activation function was used. The average blood pressure estimation error for the data obtained from 21 subjects...
-
Influence of preprocessing techniques on pulse pressure velocity determination
PublicationPulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...
-
Blood pressure and migration
Publication -
Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
PublicationNon-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...
-
Treatment of high blood pressure in elderly and octogenarians: European Society of Hypertension statement on blood pressure targets
Publication -
COMPARISON OF BLOOD PRESSURE PREDICTION METHODS
PublicationIn the paper dierent approaches of predicting blood pressure values are presented. Basically, two methods and theirs modifications are considered. In total, seven algorithms have been examined. Tests have been conducted using both synthetic and clinical data. From our study it follows that none of the examined methods is superior to other.
-
Implementation of 24-hour Blood Pressure Control
Publication -
Stability by linear approximation for time scale dynamical systems
PublicationWe study systems on time scales that are generalizations of classical differential or difference equations and appear in numerical methods. In this paper we consider linear systems and their small nonlinear perturbations. In terms of time scales and of eigenvalues of matrices we formulate conditions, sufficient for stability by linear approximation. For non-periodic time scales we use techniques of central upper Lyapunov exponents...
-
Time series of Doppler blood flow recordings
Open Research DataVital signals registration plays a grate role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomenons as well learn how to correctly process and interpret the data. This data set was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly...
-
BLOOD PRESSURE MONITORING
Journals -
Electrolyte and Blood Pressure
Journals -
Estimation of blood pressure parameters using ex-Gaussian model
PublicationThe paper presents an example of model-based estimation of blood pressure parameters (onset, systolic and diastolic pressure) from continuous measurements. First, the signal was low pass filtered and its quality was estimated. Good quality periods were divided into beats using an electrocardiogram. Next, the beginning of each beat of the blood pressure signal was approximated basing on the function created from the sum of two independent...
-
The Global Burden of Disease Study 2015 and Blood Pressure
Publication -
General practitioners ignore high normal blood pressure
Publication -
Blood Pressure in 2016: increased impact factor and change of editors
Publication -
Blood pressure control – Slowly getting there through new strategies?
Publication -
Treatment of high blood pressure in acute stroke – The SCAST Study
Publication -
Cost‐effectiveness of blood pressure measurement and hypertension follow‐up
Publication -
Blood pressure variability: Emerging role in risk assessment and therapeutics
Publication -
BLOOD PRESSURE ESTIMATION BY MEANS OF A JOINT IMPEDANCE– PHOTOPLETYSMOGRAPHIC METHOD
PublicationThe knowledge of patient’s day to day blood pressure changes is invaluable to physicians for both diagnostics and health monitoring reasons. Constant observation of the pressure throughout a day would provide even more valuable clinical information. A convenient non-invasive methods of blood pressure estimation for monitoring purposes are widely proposed. This work shows a statistical approach to...
-
The accuracy of SpaceLabs 90207 in blood pressure monitoring in patients with atrial fibrillation
Publication -
The INTERSALT Study and the complex relationship between salt intake and blood pressure
Publication -
Blood Pressure celebrates 20 years of dedication to Nordic hypertension research
Publication -
On various modelling approaches to real-time visualisation of blood flow
PublicationThis paper reviews various modelling approaches to real-time visualisation of blood flow. These include classic, macroscale approach based on the momentum conservation equation together with a proper constitutive equation. Moreover, modern micro- and mesoscale approaches, such as molecular dynamics and dissipative particle dynamics, are discussed. Advantages and disadvantages of the discussed methods are highlighted with particular...
-
Challenges in oscillometric blood pressure measurement in atrial fibrillation: looking for practical solutions
Publication -
More is Less? Optimal Combination Therapy for Adequate Blood Pressure Lowering in Hypertension
Publication -
Integrated Blood Pressure Control
Journals -
Longitudinal tracking of muscle sympathetic nerve activity and its relationship with blood pressure in subjects with prehypertension
Publication -
Impact of slow breathing on the blood pressure and subarachnoid space width oscillations in humans
PublicationThe aim of the study was to assess cardiac and respiratory blood pressure (BP) and subarachnoid space (SAS) width oscillations during the resting state for slow and fast breathing and breathing against inspiratory resistance. Experiments were performed on a group of 20 healthy volunteers (8 males and 12 females; age 25.3 ± 7.9 years; BMI = 22.1 ± 3.2 kg/m2). BP and heart rate (HR) were measured using continuous finger-pulse photoplethysmography....
-
Supine blood pressure normalised by daytime series values is independently associated with ischaemic wake-up stroke
Publication -
Blood pressure lowering effect of renal sympathetic denervation or placebo? - building expectations for Symplicity-HTN 3
Publication -
Ambulatory Blood Pressure Adds to Explaining Benefits of AT‐1 Receptor Blockade in the Treatment of Left Ventricular Hypertrophy
Publication -
High-normal blood pressure is associated with increased resting sympathetic activity but normal responses to stress tests
Publication -
Pulse pressure amplification in relation to body fatness
Publication -
Twenty‐four‐hour and conventional blood pressure components and risk of preterm delivery or neonatal complications in gestational hypertension
Publication -
High mortality explained by mildly elevated blood pressure in Scandinavian adolescent conscripts – A plea for early drug treatment?
Publication -
Urgent need to address quality control issues of out‐of‐office blood pressure measurement and patient risk assessment
Publication -
Stability by linear approximation for time scale dynamical systems
Publication -
Masked hypertension in type 2 diabetes: never take normotension for granted and always assess out-of-office blood pressure
Publication -
The J-curve phenomenon revisited again: SPRINT outcomes favor target systolic blood pressure below 120 mmHg
Publication -
Which Target Blood Pressure in Year 2018? Evidence from Recent Clinical Trials
Publication -
Coupling between Blood Pressure and Subarachnoid Space Width Oscillations during Slow Breathing
PublicationThe precise mechanisms connecting the cardiovascular system and the cerebrospinal fluid (CSF) are not well understood in detail. This paper investigates the couplings between the cardiac and respiratory components, as extracted from blood pressure (BP) signals and oscillations of the subarachnoid space width (SAS), collected during slow ventilation and ventilation against inspiration resistance. The experiment was performed on...
-
Increased inspiratory resistance affects the dynamic relationship between blood pressure changes and subarachnoid space width oscillations
PublicationBackground and objective Respiration is known to affect cerebrospinal fluid (CSF) movement. We hypothesised that increased inspiratory resistance would affect the dynamic relationship between blood pressure (BP) changes and subarachnoid space width (SAS) oscillations. Methods Experiments were performed in a group of 20 healthy volunteers undergoing controlled intermittent Mueller Manoeuvres (the key characteristic of the procedure...
-
Acute hypoxia diminishes the relationship between blood pressure and subarachnoid space width oscillations at the human cardiac frequency
PublicationAcute hypoxia exerts strong effects on the cardiovascular system. Heart-generated pulsatile cerebrospinal fluid motion is recognised as a key factor ensuring brain homeostasis. We aimed to assess changes in heart-generated coupling between blood pressure and subarachnoid space width oscillations during hypoxic exposure.