Search results for: DOUBLY FED INDUCTION GENERATOR
-
State Observer for Doubly-fed Induction Generator
PublicationIn the paper a new state observer for doubly-fed generator has been proposed. In the new approach an extended mathematical model of the doubly fed generator is used to form equations of the introduced z type observer. Stability of the observer has been verified through poles placement analyses. The active and reactive powers of the generator are controlled by a nonlinear multiscalar control method. Simulation and experimental results...
-
A Novel Speed Observer for Doubly-Fed Induction Generator
PublicationThe purpose of this paper is to show a new state observer for doubly-fed generator. A proposed z-type observer algorithm based on mathematical model of doubly fed generator with additional variables treated as a disturbances has been used. A nonlinear multiscalar control method has been used to control active and reactive power of the generator. All analyses were verified by simulations and experiments tests.
-
Cascaded doubly fed induction generator using PFC rectifiers
Publication -
Non-Adaptive Speed and Position Observer of Doubly-Fed Induction Generator
PublicationThe non-adaptive speed and position estimation of a doubly-fed induction generator (DFIG) is presented in this paper. The speed observer is based on the mathematical model of DFIG and to stabilize the structure the Lyapunov method is used. The classic stator field-oriented control to active and reactive power control is used in the sensorless control system. The performance of the proposed algorithm of a speed observer is validated...
-
Development and performance analysis of a novel multiphase doubly-fed induction generator
PublicationThis paper presents the research into the design and performance analysis of a novel five-phase doubly-fed induction generator (DFIG). The designed DFIG is developed based on standard induction motor components and equipped with a five-phase rotor winding supplied from the five-phase inverter. This approach allows the machine to be both efficient and reliable due to the ability of the five-phase rotor winding to operate during...
-
Fault-tolerant performance of the novel five-phase doubly-fed induction generator
PublicationThe article presents the concept of a new design of a multi-phase doubly-fed induction generator (DFIG). The innovative design approach uses a five-phase power supply from the rotor side of the generator with a three-phase classic stator power supply. Modern three-phase doubly-fed induction generators are the dominant choice for Wind Energy Conversion Systems (WECS). Solutions of this type are sensitive to the loss of at least...
-
Design advantages and analysis of a novel five-phase doubly-fed induction generator
PublicationPurpose – The purpose of this paper is to provide an analysis of the performance of a new five-phase doubly fed induction generator (DFIG). Design/methodology/approach – This paper presents the results of a research work related to fivephase DFIG framing, including the development of an analytical model, FEM analysis as well as the results of laboratory tests of the prototype. The proposed behavioral level analytical model is based...
-
Real-time hybrid model of a wind turbine with doubly fed induction generator
PublicationIn recent years renewable sources have been dominating power system. The share of wind power in energy production increases year by year, which meets the need to protect the environment. Possibility of conducting, not only computer simulation, but also laboratory studies of wind turbine operation and impact on the power system and other power devices in laboratory conditions would be very useful. This article presents a method...
-
Steady State Analysis of Twin Stator Cascaded Doubly Fed Induction Generator
Publication -
Sensorless Rotor Position Estimation of Doubly-Fed Induction Generator Based on Backstepping Technique
PublicationThis paper proposes a speed observer algorithm for the sensorless control of a doubly-fed induction generator based on classical adaptive backstepping technique. The sensorless control is shown using classic stator field oriented control which is used to active and reactive power control. Performance of the proposed algorithm of a speed observer is validated by simulation and experimental results obtained using a small-rating generator...
-
Cascaded doubly fed induction generator for mini and micro power plants connected to grid
Publication -
Simulation Studies of Control Systems for Doubly Fed Induction Generator Supplied by the Current Source Converter
PublicationThe control system for a Doubly Fed Induction Generator (DFIG) supplied by a grid-connected Current Source Converter (CSC) is presented in this paper. Nonlinear transformation of DFIG model to the multi-scalar form is proposed. The nonlinear control strategy of active and reactive power of DFIG is realized by feedback linearization. In the proposed control scheme, the DFIG model and CSI parameters are included. Two Proportional-Integral...
-
Non-Adaptive Speed and Position Estimation of Doubly-Fed Induction Generator in Grid-Connected Operations
PublicationThe nonadaptive speed and position estimation scheme for a doubly-fed induction generator (DFIG) is presented in this article. The observer structure is based on the extension of the mathematical model of DFIG to the introduced H vector. Based on the defined H vector, the nonadaptive position and speed estimation is proposed. The Lyapunov method is extended to the practical stability theorem to stabilize the structure. The classic...
-
Winding function approach based design of novel five-phase brushless doubly fed induction generator
PublicationThe paper presents the concept of the new design of the five-phase brushless doubly fed induction generator. The generator is dedicated to the modern wind turbine. The innovative design approach uses a five-phase power supply from the stator control winding side of the generator with a stator three-phase classic power winding. The research results presented indicate that the electromagnetic coupling between the control and power...
-
Nonlinear Control of a Doubly Fed Generator Supplied by a Current Source Inverter
PublicationNowadays, wind turbines based on a doubly fed induction generator (DFIG) are a commonly used solution in the wind industry. The standard converter topology used in these systems is the voltage source inverter (VSI). The use of reverse-blocking insulated gate bipolar transistor (RB-IGBT) in the current source inverter topology (CSI), which is an alternative topology, opens new possibilities of control methods. This paper presents...
-
Feedback Control of Doubly-Fed Generator Connected to Current Source Converter
PublicationDoubly-fed induction generator (DFIG) system supplied by current source converter (CSC) is considered in this article. The DFIG can work in two independent modes: AC grid connection and stand-alone mode. The DFIG is connected to the ac grid directly through its stator and the CSC links the rotor side. In this mode, the active and reactive powers of the DFIG must be controlled. This article proposes two control system structures...
-
Non-linear circuit model of a single doubly-fed induction machine formulated in natural axes for drive systems simulation purposes
PublicationMathematical modelling and a circuit model formulated in natural axes of a single doubly-fed induction machine, with the account of magnetic circuit nonlinearity are presented in the paper. Derivation of the model differential equations was based on Lagrange's energy method. State functions of magnetic elements in the model are non-linear and depend on all currents flowing in the machine windings and on the angle of rotor position....
-
Control of the wind turbine generator
PublicationWind power system consists of two main parts: wind turbine and electrical generator. Wind turbine converts the energy of the flowing air into mechanical energy, next generator converts this energy into electrical energy that is sent to the power system. These two processes should be realized with maximum efficiency and the following requirements for the control system can be formulated: opti-mal wind power conversion, compensation...
-
Sensorless Fault Detection of Induction Motor with Inverter Output Filter
PublicationThe paper presents the problem of monitoring and fault detection of a sensorless voltage inverter fed squirrel cage induction motor with LC filter. The detection is based on load torque estimation of the investigated torque transmission system. The load torque is calculated besides the computation of other variables that are mandatory for sensorless drive operation such as rotor flux and speed. The implemented LC filter smooths...
-
Research of Emergency Modes of Wind Power Plants Using Computer Simulation
PublicationThe aim of this study is to investigate changes in the wind power plant energy production parameters under the conditions of sudden wind changes and voltage drop. To achieve these goals, a simulation of operation of wind power plants was performed. Twelve wind turbines with variable rotational speed equipped with a Fuhrländer FL 2500/104 asynchronous double-fed induction generator (DFIG) were used, each with an installed capacity...