Search results for: ELECTRICAL SAFETY - Bridge of Knowledge

Search

Search results for: ELECTRICAL SAFETY

Search results for: ELECTRICAL SAFETY

  • Electrical safety in medical locations

    Publication

    - Year 2005

    W artykule zwrócono uwagę na niezawodność zasilania i ochronę przeciwporażeniową w pomieszczeniach użytkowanych medycznie. Przedstawiono wymagania stawiane zasilaniu, zabezpieczeniom i obwodom sygnalizacji w tych pomieszczeniach, według norm międzynarodowych. Zaprezentowano zasady doboru zabezpieczeń ochronnych oraz przykładowe rozwiązanie zasilania sali operacyjnej w szpitalu.

  • Electrical safety in low-voltage DC microgrids with B-type residual current devices

    Publication

    Residual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...

    Full text available to download

  • Blended Learning in Teaching Safety of Electrical Installations

    Publication

    - Year 2014

    Blended learning becomes more commonly used in teaching information technology or other subjects, which involve practice in computer laboratories. In case of subjects with no access to computer rooms blended learning supports lecturing and teaching classes e.g. interactive lessons. The article presents the use of blended learning forms in Gdansk University of Technology in teaching the subject of Safety of Electrical Installations....

    Full text to download in external service

  • Integrity level verification for safety-related functions

    This article describes methods for safety integrity level (SIL) verification of safety-related functions with regard to probabilistic criteria given international standards IEC 61508 and IEC 61511. These functions are to be realized using the electrical, electronic and programmable electronic (E/E/PE) systems or safety instrumented systems (SIS). Some methods are proposed for quantitative probabilistic modelling taking into account...

  • PV installations and the safety of residential buildings

    The dynamic development of the photovoltaic industry entails threats that have a direct impact on the safety of residential buildings. Appropriate design of a PV installation can be a challenge due to the multifaceted nature of this issue. The designer should take into account issues related to the selection of electrical parameters of the installation, adapting lightning and surge protection in accordance...

    Full text available to download

  • Evaluation of fire hazard in electrical installations due to unfavorable ambient thermal conditions

    Publication

    - Fire - Year 2023

    Evaluation of fire hazard caused by electrical installations is a difficult and important topic, and it limits the possibility of loss of life or health of people, as well as the occurrence of significant property damage. In particular, this hazard was caused by power cables and especially photovoltaic (PV) installations. The authors proved that power cables directly exposed to strong solar radiation are likely to exceed maximum...

    Full text available to download

  • Analytical and reliability data from the real-time simulator biogas plant

    Open Research Data

    The dataset represents the results of biogas plant simulation. The described plant is an agricultural biogas system, which can produce electrical energy with power estimated up to 1070 kW and heat energy that can reach 1200 kW simultaneously.

  • Determining and verifying the safety integrity level of the controland protection systems under uncertainty

    Publication

    The probabilistic models of the electrical, electronic and programmable electronic (E/E/PE)systems, which are proposed in the IEC 61508 and IEC 61511 standards, do not cover the uncertainty aspectsof results obtained from these models. The proposed method takes into consideration the sensitivity analysisof probabilistic models of E/E/PE systems as well as the uncertainty of probabilistic results. It uses differentialfactors, which...

  • LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations

    Publication

    - Year 2017

    Evaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...

    Full text to download in external service

  • Bezpieczeństwo elektroenergetyczne dla pokoleń

    Publication
    • W. Kamrat
    • M. Bartosik
    • M. Każmierkowski
    • L. Włodzmierz
    • P. Maciej
    • T. Peryt
    • T. Skoczkowski
    • S. Andrzej
    • S. Adam

    - Przegląd Elektrotechniczny - Year 2016

    W artykule przeanalizowano źródła energii pierwotnej, ich wystarczalnośći dywersyfikację w skali lokalnej i globalnej, problem dekarbonizacji polskiej elektroenergetyki na tle europejskiej polityki klimatycznej, osiągalność źródeł gazu jako efektywnego paliwa dla energetyki, polski program energetyki jądrowej, bezpieczeństwo zasilania elektrycznych systemów trakcyjnych jako strategicznej alternatywy...

    Full text available to download

  • Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection

    Publication

    This paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...

    Full text available to download

  • The effect of current delay angle on tripping of residual current devices

    Publication

    - Year 2017

    Power electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....

    Full text to download in external service

  • Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits

    Publication

    Verification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...

    Full text available to download

  • Fuzzy Control of Waves Generation in a Towing Tank

    Publication

    This paper presents the results of research related to the transformation of electrical energy into potential and kinetic energy of waves generated on the water surface. The waves are generated to model the environmental conditions for the needs of the model tests. The model tests are performed on model-scale objects to predict the features of full-scale maritime objects. It is done to improve human safety and the survivability...

    Full text available to download

  • Assessment of under power ed propulsion machinery in electrically driven small inland waterway passenger ships from classification society point of view

    Publication

    - Year 2014

    Paper presents short operat ional a nd engineering analysis of underpowered propulsion in small electrically propelled small inland passenger ships. There is evidence that in certain weather conditions the phenomena of added aerodynamic resistance of small water crafts may have seriou s influence on their speed and manoeuvrability. Existing regulations like class societies rules for ship classification and construction or EU Directive 2006/87/EC do...

    Full text to download in external service

  • ASSESSMENT OF UNDERPOWER ED PROPULSION MACHINERY IN ELECTRICALLY DRIVEN SMALL INLAND WATERWAY PASSENGER SHIPS FROM CLASSIFICATION SOCIETY POINT OF View

    Publication

    - Journal of Polish CIMEEAC - Year 2014

    Paper presents short operat ional a nd engineering analysis of underpowered propulsion in small electrically propelled small inland passenger ships. There is evidence that in certain weather conditions the phenomena of added aerodynamic resistance of small water crafts may have serious influence on their speed and manoeuvrability. Existing regulations like class societies rules for ship classification and construction or EU Directive 2006/87/EC do...

    Full text available to download

  • CFFT columns in road through railroad crossings

    Publication

    There were 12801 road through railroad one-level crossings in Poland in 2018. 215 accidents happened at them in 2018. In order to increase safety in rail and road traffic two-level crossings should be used. They are definitely safer and make the traffic more smooth. In the design and construction of two-level intersections of railway and road or path columns of circular cross-section are often used. They can be successfully replaced...

    Full text to download in external service

  • Behavior of residual current devices at earth fault currents with DC component

    Publication

    - SENSORS - Year 2022

    Low-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...

    Full text available to download

  • Arsalan Muhammad Soomar Doctoral Student

    People

    Hi, I'm Arsalan Muhammad Soomar, an Electrical Engineer. I received my Master's and Bachelor's Degree in the field of Electrical Engineering from Mehran University of Engineering and Technology, Jamshoro, Sindh, Pakistan.  Currently enrolled as a Doctoral student at the Gdansk University of Technology, Gdansk, Poland. Also worked in Yellowlite. INC, Ohio  as a Solar Design Engineer.   HEADLINE Currently Enrolled as a Doctoral...

  • Electric shock hazard in circuits with variable-speed drives

    The conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50/60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives...

    Full text available to download