Filters
total: 5470
-
Catalog
displaying 1000 best results Help
Search results for: LEAKAGE CURRENT MEASUREMENT
-
Leakage Current Measurements of Surge Arresters
PublicationThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...
-
The problem of “spectrum leakage” in the measurement of harmonics
Publication -
Determining the leakage current resistive component by the orthogonal vector method
PublicationThe measurement of the metal – oxide surge arresters (MOSA) leakage current and the analysis of its components is a key diagnostic criterion according to technical standards. During on site MOSA condition assessment, the easy way is based on the measurement only leakage current, without the inconvenient live working measurements of supply voltage. Orthogonal vectors method of determination the resistive leakage current is presented....
-
Immunity of residual current devices to the impulse leakage current in circuits with variable speed drives
PublicationThis paper concerns reliability of supply in variable speed drive circuits with residual current devices. During normal operation of these circuits high value of leakage current causes unwanted tripping of residual current devices. Immunity of residual current devices to the impulse leakage current should be evaluated. The system for testing of residual current devices and results of the test are presented
-
The Effect of the Phenomenon of “Spectrum Leakage” on the Measurement of Power Quality Parameters
Publication -
Measurement cell - current density analysis.
PublicationW pracy przedstawiono model celki do pomiarów elektrycznych parametrów szkliwa i innych tkanek zęba. Wyniki otrzymano za pomocą metody elementu skończonego. Wykazano, że możliwa do osiągnięcia dokładność pomiaru jest zdeterminowana przez prąd upływu celki.
-
Remote current measurement with FPGA digital processing
PublicationThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
Current measurement and analysis for induction motor diagnostics
PublicationPrzedstawiono sposób diagnozowania łożysk tocznych w silnikach indukcyjnych z wykorzystaniem pomiarów i analizy prądu zasilającego silnik. Zaprezentowano metodę pomiarową i opracowania danych diagnostycznych. Uzyskano zgodność częstotliwości składowych widma prądu otrzymanych z badań teoretycznych i eksperymentalnych.Podano wyniki badań łożysk o róznych uszkodzeniach i prawdopodobieństwa poprawnych diagnoz.
-
Visual measurement system for chosen parameters of current collectors
PublicationA current collector is an element in a traction vehicle, used for movable, contact con-nection between the main circuit of this vehicle and the contact line. Bad technical condi-tion of these important elements in the main circuit of the vehicle result in its incorrect cooperation with contact line. Periodic control of technical condition of current collectors ensures infallible current collection. The pantograph diagnostics consists...
-
Method and measurement system for DC characteristics measurement of power diodes in very wide current range
PublicationW artykule przedstawiono układ pomiarowy do pomiaru charakterystyk stałoprądowych diod. Pomiar przeprowadzany jest metodą impulsową w celu zapewnienia stałej temperatury badanego elementu w trakcie pomiaru. Do zapewnienia odpowiedniej liczby punktów pomiarowych wykorzystano układ zmodyfikowanej drabinki R2R z pojedynczymi kluczami sterującymi.
-
Indirect Measurement of Motor Current Derivatives in PMSM Sensorless Drives
PublicationMotor current derivatives contain useful information for control algorithms, especially in sensorless electric drives. The measurement of motor current derivatives in electric motors supplied by voltage source inverter can be performed using di/dt transducers. However, in such a solution additional sensors have to be installed, e.g. Rogowski coils. Another approach is to measure current derivatives indirectly – by oversampling...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublicationW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Comparison of induction motor bearing diagnostic test results through vibration and stator current measurement
PublicationThe paper discusses results of tests performed by authors, related to the angine bearings diagnostic using vibration and stator current measurements. The paper contains the description of an automatic measurement system, developed for measurement of those harmonics and processing that to obtain bearing diagnostic information. System was tested on objects with intentionally made defects in bearings, results of this test was also...
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublicationThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
Optoelectronic properties of the metal-tetracene interface investigated by current noise measurement under monochromatic irradiation.
PublicationZaprezentowano badania prądów ograniczonych elektrodowo w warstwach tetracenu. Szczególną uwagę zwrócono na zależność szumów elektrycznych od przyłożonego napięcia i padającego światła.
-
O zastosowaniu metody prądów wirowych do technicznego pomiaru własności elektrycznych i magnetycznych metali = About application of eddy current method for technical measurement of electric and magnetic properties of metals
PublicationOpisano wyniki badań nad wykorzystaniem efektu prądów wirowych do badania własności elektrycznych i magnetycznych metali. Badania wykonano za pomocą sondy różnicowej. Wyniki pomiarów zależności częstotliwościowej wykonane dla modelowych materiałów porównano z wynikami modelowania metodą elementów skończonych.
-
The voltage across and current through the RC model object tested using pulse excitation in impedance spectroscopy measurement method
Open Research DataThe raw data (voltage across and current through RC model object ) obtained using pulse excitation EIS impedance spectroscopy measurement method. The data was acquired using 12-bit ADC (LTC1420) with sampling frequency changed in time segments. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. For...
-
Residual Current Devices: Selection, Operation, and Testing
PublicationIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...