Filters
total: 2842
-
Catalog
displaying 1000 best results Help
Search results for: OVER-ACTUATED CONTROL, ADAPTIVE CONTROL, LYAPUNOV FUNCTION, CONTROL ALLOCATION, MIMO SYSTEM DOI
-
Cathodic Protection System of the Spiral Classifier at the KGHM Polska Miedź S.A. Ore Concentration Plant—Case Study of Commissioning and Control of Operating Parameters
PublicationThe project involved designing, constructing and commissioning a cathodic protection system for a selected spiral classifier operating at the KGHM Polska Miedź S.A. Ore Concentration Plant (O/ZWR). The authors developed a concept and assumptions regarding the corrosion protection of a large industrial device using a cathodic protection system with an external power source. Pre-project studies included conducting a trial polarization...
-
Paweł Kowalski dr inż.
People -
Ryszard Strzelecki prof. dr hab. inż.
People -
Journal of Low Frequency Noise Vibration and Active Control
Journals -
An International Journal of Optimization and Control: Theories & Applications (IJOCTA)
Journals -
Kongzhi Lilun Yu Yinyong/Control Theory and Applications
Journals -
Dianji yu Kongzhi Xuebao/Electric Machines and Control
Journals -
JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME
Journals -
Design of three-phase three-level CIC T-source inverter with maximum boost control
Publication -
Application of Feedback Linearization for Air Gap Flux Control of Induction Motor in the Field Weakening Region
Publication -
Chatter Vibration Surveillance by the Optimal-linear Control of Spindle Speed and Randomly Varying Spindle Speed
PublicationW artykule opisano dynamikę procesu skrawania smukłym frezem kulistym. Jako metodę nadzorowania drgań chatter zastosowano zmienną prędkość obrotową wrzeciona. Jest ona dobierna z wykorzystaniem energetycznego wskaźnika jakości co prowadzi do optymalno-liniowego sterowania prędkością obrotową. Dodatkowo zastosowano nadzorowanie drgań chatter poprzez losowo zmienną prędkość obrotową.
-
The possible unreliability of self-efficacy beliefs and perceived control - when nascent entrepreneurs may be overconfident
Publicationpoczucie samoskuteczności oraz poziom postrzeganej kontroli są istotnymi czynnikami decydującymi o wyborze działań oraz o wytrwałości w ich kontynuowaniu. zbyt wysokie poczucie samoskuteczności, które znacznie odbiega od faktycznej skuteczności oraz iluzja kontroli mogą powodować nadmierne zaangażowanie w działania, które mają znikome szanse powodzenia. artykuł przedstawia teoretyczną analizę znaczenia różnych źródeł poczucia samoskuteczności...
-
A frequency-domain surveillance of the robot's structural vibration with a use of modal control at energy performance index
PublicationRozważano drgania niestacjonarnego układu nośnego robota IRb-6. W celu nadzorowania drgań zastosowano algorytm sterowania modalnego przy energetycznym wskaźniku jakości w dziedzinie częstotliwości. Podejście takie umożliwia wykorzystanie elementów projektowania mechatronicznego do nadzorowania drgań, którego celem jest minimalizacja amplitudy drgań końcówek manipulacyjnych, a w konsekwencji - poprawa dokładności i powtarzalności...
-
Simplified simulation technique of rotating, induction heated, calender rolls for study of temperature field control
Publication -
Applying Hidden Markov Models to Visual Activity Analysis for Simple Digital Control Panel Operations
Publication -
Safety and outcomes of laparoscopic sleeve gastrectomy in patients older than 60: a case-control study
Publication -
Automatic resource identification for FPGA-based reconfigurable measurement and control systems with mezzanines in FMC standard
Publication -
Linking Macro- and Micro-structural Analysis with Luminescence Control in Oxynitride Phosphors for Light-Emitting Diodes
Publication -
ppGpp-Dependent Negative Control of DNA Replication of Shiga Toxin-Converting Bacteriophages in Escherichia coli
Publication -
Hidden Structural Evolution and Bond Valence Control in Near-Infrared Phosphors for Light-Emitting Diodes
Publication -
Grid-Forming Operation of Energy-Router Based on Model Predictive Control with Improved Dynamic Performance
Publication -
Multiobjective Water Distribution Systems Control of Pumping Cost, Water Quality, and Storage-Reliability Constraints
PublicationThis work describes a multiobjective model for trading-off pumping cost and water quality for water distribution systems operation. Constraints are imposed on flows and pressures, on periodical tanks operation, and on tanks storage. The methodology links the multiobjective SPEA2 algorithm with EPANET, and is applied on two example applications of increasing complexity, under extended period simulation conditions and variable energy...
-
Interpretation and modeling of emotions in the management of autonomous robots using a control paradigm based on a scheduling variable
PublicationThe paper presents a technical introduction to psychological theories of emotions. It highlights a usable ideaimplemented in a number of recently developed computational systems of emotions, and the hypothesis thatemotion can play the role of a scheduling variable in controlling autonomous robots. In the main part ofthis study, we outline our own computational system of emotion – xEmotion – designed as a key structuralelement in...
-
Ambulatory blood pressure in mild hypertensive women taking oral contraceptives a case-control study
Publication -
Phytochemical Profiling and Larval Control of Erythrina variegata Methanol Fraction against Malarial and Filarial Vector
Publication -
Bending Moment Control and Weight Optimization in Space Structures by Adding Extra Members in the Optimal Locations
PublicationThis paper investigates the reduction of bending moment in critical members by adding some extra members in the optimum location. Instead of enlarging the size of members to resist the moment, eight additional members are added in the optimum location to reduce the bending moment in the critical members. The total weight of the proposed structure with extra members is less than that of the original structure that resists the induced...
-
Remote command and control capabilities for data acquisition systems provided by delay-tolerant network mechanisms
PublicationThe paper presents an assessment of a remote device reconfiguration service employing a Delay Tolerant Network (DTN) mechanisms. This service has been implemented as a part of a communication appliance dedicated to marine data transfer in off-shore and open sea areas. The service has been successfully deployed and validation test have been completed. The practical use-case has been defined as remote access to the equipment operating...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.7, b=0.32) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.1, b=0.14) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.8, b=0.25) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.5, b=0.37) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.4, b=0.26) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.0, b=0.11) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.5, b=0.37) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.8, b=0.25) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=6.8) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=5.7, b=0.32) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.1, b=0.14) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...