Search results for: flicker noise - Bridge of Knowledge

Search

Search results for: flicker noise

Search results for: flicker noise

  • Measurements of flicker noise in supercapacitor cells

    Publication

    - Year 2017

    Flicker noise (1/f-like noise) is often used to assess the quality of various materials and devices. This phenomenon has been observed in different electrochemical devices or reactions (e.g., smart windows, pitting corrosion events). In our exploratory studies we consider how to measure and utilize 1/f noise for the quality assessment of supercapacitors. This task requires special attention because of enormous capacitance of the...

    Full text to download in external service

  • Probability distribution of flicker noise in AuNPdecorated graphene–Si Schottky barrier diode

    Publication

    - Year 2023

    We present results of the probability distribution analysis of flicker noise generated in Au nanoparticle (AuNP) decorated graphene–Si Schottky barrier diodes with and without yellow light illumination (592 nm), close to the localized surface plasmon resonance in the AuNPs (586 nm). The AuNPs occupy imperfections in the single-layer graphene and reduce the flicker noise intensity generated in the graphene layer. The estimated probability...

    Full text to download in external service

  • Flicker Noise in Resistive Gas Sensors—Measurement Setups and Applications for Enhanced Gas Sensing

    Publication

    - SENSORS - Year 2024

    We discuss the implementation challenges of gas sensing systems based on low-frequency noise measurements on chemoresistive sensors. Resistance fluctuations in various gas sensing materials, in a frequency range typically up to a few kHz, can enhance gas sensing by considering its intensity and the slope of power spectral density. The issues of low-frequency noise measurements in resistive gas sensors, specifically in two-dimensional...

    Full text available to download

  • MEASUREMENT OF NOISE IN SUPERCAPACITORS

    A developed method and measurement setup for measurement of noise generated in a supercapacitor is presented. The requirements for noise data recording are considered and correlated with working modes of supercapacitors. An example of results of low-frequency noise measurements in commercially available supercapacitors are presented. The ability of flicker noise measurements suggests that they can be used to assess quality of tested supercapacitors.

    Full text available to download

  • Assessment of Fuel Cells’ State of Health by Low-Frequency Noise Measurements

    We proposed applying low-frequency (flicker) noise in proton-exchange membrane fuel cells under selected loads to assess their state of health. The measurement set-up comprised a precise data acquisition board and was able to record the DC voltage and its random component at the output. The set-up estimated the voltage noise power spectral density at frequencies up to a few hundred mHz. We observed the evolution of the electrical...

    Full text available to download

  • Effects of mechanical stress on electrical arameters and noise of supercapacitors

    Publication

    Results of noise and electrical parameters measurements of prototype electrochemical double layer capacitors (EDLC) are reported at the presence of selected mechanical stress. This issue is of great importance due to future applications in wearable technology. The measurement results are compared, and we may conclude than flicker noise is more sensitive to any stress than other considered electrical parameters.

    Full text available to download

  • Advanced operating methods

    Publication

    - Year 2020

    Selected operating methods of resistive gas sensors were presented. The methods utilize flicker noise (1/f noise), which gives additional information about ambient gas when compared with the recorded changes of DC resistance only. Methods of flicker noise measurements were outlined. Recently developed prototype gas sensors comprising golden nanoparticle functionalized with organic ligands can generate intense flicker noise induced...

    Full text to download in external service

  • Perspectives of Fluctuation-Enhanced Gas Sensing by Two-Dimensional Materials

    We present the results of gas sensing using the fluctuation-enhanced sensing method in selected two-dimensional materials (2DMs). We claim that gas sensing selectivity can be improved further by considering semiconducting two-dimensional materials doped by noble metal nanoparticles. The 2DMs' structures exhibit some imperfections defined by their structure, occurring repeatedly there. These imperfections are adsorption-desorption...

    Full text available to download

  • Investigation of noises in the EPN weekly time series

    Publication
    • A. Klos
    • J. Bogusz
    • M. Figurski
    • M. Gruszczyńska
    • M. Gruszczyński

    - Acta Geodynamica et Geomaterialia - Year 2015

    The constantly growing needs of permanent stati ons’ velocities users cause their stability level to increase. To this research we included more than 150 stations located across Europe operating within the EUREF Permanent Network (EPN) w ith weekly changes in the ITRF2005 reference frame. The obvious long-range dependencies in the stochastic part of GPS time series were p roven by Ljung-Box...

    Full text available to download

  • Noise Analysis of Continuous GPS Time Series of Selected EPN Stations to Investigate Variations in Stability of Monument Types

    Publication

    - Year 2016

    The type of monument that a GPS antenna is placed on plays a significant role in noise estimation for each permanent GPS station. In this research 18 Polish permanent GPS stations that belong to the EPN (EUREF Permanent Network) were analyzed using Maximum Likelihood Estimation (MLE). The antennae of Polish EPN stations are placed on roofs of buildings or on concrete pillars. The analyzed data covers a period of 5 years from 2008...

    Full text to download in external service

  • Effects of UV light irradiation on fluctuation enhanced gas sensing by carbon nanotube networks

    Publication

    - SENSORS AND ACTUATORS B-CHEMICAL - Year 2022

    The exceptionally large active surface-to-volume ratio of carbon nanotubes makes it an appealing candidate for gas sensing applications. Here, we studied the DC and low-frequency noise characteristics of a randomly oriented network of carbon nanotubes under NO2 gas atmosphere at two different wavelengths of the UV light-emitting diodes. The UV irradiation allowed to sense lower concentrations of NO2 (at least 1 ppm) compared to...

    Full text available to download

  • Investigation of long-range dependencies in the stochastic part of daily GPS solutions

    Publication

    - SURVEY REVIEW - Year 2016

    The long-range dependence (LRD) of the stochastic part of GPS-derived topocentric coordinates change (North, East, Up) results with relatively high autocorrelation values with a focus on self-similarity. One of the reasons for such self-similarity in the GPS time series are noises that are commonly recognised to prevail in the form of the flicker noise model. To prove the self-similarity of the stochastic part of GPS time series...

    Full text to download in external service

  • Error analysis for European IGS stations

    Publication

    - STUDIA GEOPHYSICA ET GEODAETICA - Year 2016

    Each of the GPS time series that describes the changes of topocentric components consists of a deterministic and a stochastic part, whose character influences the errors of the deterministic parameters. As to the uncertainties of reliable velocities of permanent satellite station systems, surveys that estimate and take into account any dependencies that may affect subsequent operational efficiency are very important. For this analysis,...

    Full text to download in external service

  • UV Light-Modulated Fluctuation-Enhanced Gas Sensing by Layers of Graphene Flakes/TiO2 Nanoparticles

    Publication

    - Journal of Sensors - Year 2020

    We present experimental results of fluctuation-enhanced gas sensing by low-cost resistive sensors made of a mixture of graphene flakes and TiO2 nanoparticles. Both components are photocatalytic and activated by UV light. Two UV LEDs of different wavelengths (362 and 394 nm) were applied to modulate the gas sensing of the layers. Resistance noise was recorded at low frequencies, between 8 Hz and 10 kHz. The sensors’ response was...

    Full text available to download

  • Electrical and noise responses of carbon nanotube networks enhanced by UV light for nitrogen dioxide sensing

    Open Research Data
    open access

    Networks consisting of randomly oriented carbon nanotubes (CNN) were investigated toward nitrogen dioxide detection by means of electrical and low-frequency noise measurements. UV-activation of CNN layers improved gas sensitivity and reduced the limit of detection, especially by employing 275 nm-LED. This data set includes DC resistance measurements...

  • Noise sources in Raman spectroscopy of biological objects

    Publication

    - Year 2017

    We present an overview of noise sources deteriorating the quality of the recorded biological Raman spectra and the ability to determine the specimen composition. The acquired Raman spectra exhibit intense additive noise components or drifts because of low intensity of the scattered light. Therefore we have to apply expensive or bulky measurement setups to limit their inherent noise or to apply additional signal processing to reduce...

  • Fluctuation-Enhanced Sensing

    Publication

    - Journal of Sensors - Year 2020

    Fluctuation-enhanced sensing (FES) is an exciting and relatively new research field that promises to extend the range of information that can be extracted from a single sensor. In FES, the stochastic fluctuations of the sensor signal, rather than its average value, are recorded and analyzed. Typical components of such fluctuations are due to interactions at the microscopic level. Proper statistical analysis provides optimum sensory...

    Full text to download in external service

  • Noise in electrical double-layer capacitors (EDLCs)

    Publication

    We present methods and problems of noise measurements in electrical double-layer capacitors (EDLC). Detailed noise equivalent electronic circuit is considered, and two possible ways of observations of random processes generated in the EDLCs structures are studied. We conclude that noise is a useful tool for characterization of the EDLC structures and their state-of-health, as in other materials and electronic devices. Eventual,...

    Full text available to download

  • Assessment of Supercapacitor’s Quality by Means of Low Frequency Noise

    Publication

    Low frequency noise is a well-known tool for quality and reliability assessment of electronic devices. This phenomenon is observed in different electrochemical devices as well (e.g., smart windows, electrochemical corrosion processes). Thus, we can assume that the same tool can be used to asses quality of supercapacitors. Their quality is usually determined only by capacitance and/or equivalent series resistance (ESR), or impedance....

  • Fluctuation-Enhanced Sensing with Organically Functionalized Gold Nanoparticle Gas Sensors Targeting Biomedical Applications

    Publication
    • Ł. Lentka
    • M. Kotarski
    • J. Smulko
    • U. Cindemir
    • Z. Topalian
    • C. G. Granqvist
    • R. Calavia
    • R. Ionescu

    - TALANTA.The International Journal of Pure and Applied Analytical Chemistry - Year 2016

    Detection of volatile organic compounds is a useful approach to non-invasive diagnosis of diseases through breath analysis. Our experimental study presents a newly developed prototype gas sensor, based on organically-functionalized gold nanoparticles, and results on formaldehyde detection using fluctuation-enhanced gas sensing. Formaldehyde was easily detected via intense fluctuations of the gas sensor’s resistance, while the cross-influence...

    Full text available to download

  • Portable exhaled breath analyzer employing fluctuation-enhanced gas sensing method in resistive gas sensors

    This paper presents a portable exhaled breath analyser, developed to detect selected diseases. The set-up employs resistive gas sensors: commercial MEMS sensors and prototype gas sensors made of WO3 gas sensing layers doped with various metal ingredients. The set-up can modulate the gas sensors by applying UV light to induce physical changes of the gas sensing layers. The sensors are placed in a tiny gas chamber of a volume...

    Full text available to download

  • Optimum Choice of Randomly Oriented Carbon Nanotube Networks for UV-Assisted Gas Sensing Applications

    Publication
    • K. Drozdowska
    • A. Rehman
    • J. Smulko
    • A. Krajewska
    • B. Stonio
    • P. Sai
    • A. Przewłoka
    • M. Filipiak
    • K. Pavłov
    • G. Cywinski... and 2 others

    - ACS Sensors - Year 2023

    We investigated the noise and photoresponse characteristics of various optical transparencies of nanotube networks to identify an optimal randomly oriented network of carbon nanotube (CNT)-based devices for UV-assisted gas sensing applications. Our investigation reveals that all of the studied devices demonstrate negative photoconductivity upon exposure to UV light. Our studies confirm the effect of UV irradiation on the electrical...

    Full text available to download