Search results for: bioniczne ortezy
-
Perfusion computed tomography: 4 cmversus8 cm coverage size in subjects with chronic carotid artery stenosis
PublicationOBJECTIVE: The impact of coverage size on global cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT) and time to peak (TTP) parameters has not been investigated in patients with chronic carotid artery stenosis. METHODS: 63 patients with stenosis of >70% within a single internal carotid artery and neurological symptoms were randomly assigned to two well-matched groups. Differences in CT perfusion scan...
-
Piotr Odya dr inż.
PeoplePiotr Odya was born in Gdansk in 1974. He received his M.Sc. in 1999 from the Faculty of Electronics, Telecommunications and Informatics, Gdansk University of Technology, Poland. His thesis was related to the problem of sound quality improvement in the contemporary broadcasting studio. He is interested in video editing and multichannel sound systems. The goal of Mr. Odya Ph.D. thesis concerned methods and algorithms for correcting...
-
The effect of the power transmission of the spindle on the position of the circular saw teeth
PublicationNa dokładność przecinania ma decydujący wpływ położenie ostrzy piły tarczowej. W pracy analizowano przyczyny i błędy połozenia ostrzy piły w stosunku do przedmiotu obrabianego spowodowane odkształceniem wrzeciona wywołanym przez siły skrawania i siły pochodzące od napędu.
-
Wpływ zmiany parametrów geometrycznych na wydajność i efektywność protezy zastawki aortalnej Human Aortic Bioprosthesis
PublicationW pracy wykazano na podstawie rezultatów badań in vitro, że konstrukcja wykonana z nanocelulozy bakteryjnej, posiada wszelkie cechy protezy zastawki aortalnej możliwe do wykazania na drodze ww. badań oraz że określone cechy geometrii protezy wpływają na jej efektywność i funkcjonalność. W szczególności, w pracy przedstawiono wyniki badań in vitro trzech modeli konstrukcji protezy zastawki aortalnej, oznaczonych M2, M4’ i M4. Badania...
-
Vascular restenosis in coronary artery bypass grafting might be associated with VEGF-C/VEGFR-3 signaling pathway
Publication -
Cytokeratin 8 in venous grafts: A factor of unfavorable long-term prognosis in coronary artery bypass grafting patients
Publication -
The role of depressive and anxiety symptoms in the evaluation of cardiac rehabilitation efficacy after coronary artery bypass grafting surgery
Publication -
Coronary artery disease, arterial stiffness, and myocardial work: what is the role of diabetes in this vicious circle? Authors’ reply
Publication -
Role of adenylate kinase 4 as a new metabolic regulator of pulmonary artery smooth muscle cells under hypoxia
Publication -
Regional resting state perfusion variability and delayed cerebrovascular uniform reactivity in subjects with chronic carotid artery stenosis
PublicationThe aim of this study was to assess regional perfusion at baseline and regional cerebrovascular resistance (CVR) to delayed acetazolamide challenge in subjects with chronic carotid artery stenosis.Sixteen patients (ten males) aged 70.94±7.71 with carotid artery stenosis ≥90% on the ipsilateral side and ≤50% on the contralateral side were enrolled into the study. In all patients, two computed tomography perfusion examinations were...
-
Initial Report on Numerical Modeling of Blood Flow in Myocardial Bridge Region of Coronary Artery: Concept of Model Validation
PublicationThe paper presents a numerical method of blood flow simulation within the coronary artery covered by the myocardial bridge. The myocardial bridge is a congenital coronary abnormality caused by the blood vessel location under one of the heart muscles. In this case, the blood flow within the vessel is partially disturbed which can cause several consequences. The presented numerical simulation allowed us to estimate the blood flow...
-
The effect of the spindle system on the position of circular saw teeth - a static approach
PublicationW pracy przedstawiono analizę powstawania błędów położenia ostrzy piły tarczowej w stosunku do przedmiotu obrabianego. błędy te pochodzą głównie z układu wrzeciona. Wyznaczono błędy położenia ostrzy dla klasycznego rozwiązania układu wrzeciona oraz dla nowego rozwiązania konstrukcyjnego proponowanego przez autorów.
-
Mariusz Kaczmarek dr hab. inż.
PeopleReceived M.Sc., Eng. in Electronics in 1995 from Gdansk University of Technology, Ph.D. in Medical Electronics in 2003 and habilitation in Biocybernetics and Biomedical Engineering in 2017. He was an investigator in about 13 projects receiving a number of awards, including four best papers, practical innovations (7 medals and awards) and also the Andronicos G. Kantsios Award and Siemens Award. Main research activities: the issues...
-
Angiotensin converting enzyme gene polymorphism is associated with severity of coronary artery disease in men with high total cholesterol levels
Publication -
Comparison of the effects of rosuvastatin monotherapy and atorvastatin-ezetimibe combined therapy on the structure of erythrocyte membranes in patients with coronary artery disease
Publication -
A pilot study with flow mediated skin fluorescence: A novel device to assess microvascular endothelial function in coronary artery disease
PublicationBackground: Endothelial dysfunction is one of the earliest vascular manifestations in the pathogenesis of cardiovascular disease. Noninvasive, simple and inexpensive methods of endothelial function assessment are therefore needed. Methods: Microvascular endothelial function was assessed in coronary artery disease (CAD) patients by flow mediated skin fluorescence (FMSF), based on measurements of NADH fluorescence intensity during...
-
Komputerowe stanowisko pomiarowe do analizy dokładności wykonania krawędzi ostrzy narzędzi z wykorzystaniem obrazów z kamer.
PublicationW referacie przedstawiono zaprojektowane, wykonane i wdrożone komputerowe stanowisko pomiarowe do analizy dokładności wykonania krawędzi ostrzy narzędzi. Analiza dokładności zrealizowana została na podstawie zarejestrowanych obrazów z kamer. Przedstawiono opisy konstrukcji części mechanicznej stanowiska, układu sterowania, a także ogólną charakterystykę algorytmów sterowania.
-
First-Phase Left Ventricular Ejection Fraction as an Early Sign of Left Ventricular Dysfunction in Patients with Stable Coronary Artery Disease
Publication -
The influence of statin monotherapy and statin-ezetimibe combined therapy on FoxP3 and IL 10 mRNA expression in patients with coronary artery disease
Publication -
Metoda oceny dokładności położenia ostrzy pił tarczowych w procesie przecinania materiałów drzewnych na podstawie warunków skrawania
PublicationW pracy przeprowadzono zarówno badania teoretyczne, jak również badania doświadczalne dokładności położenia ostrzy pił tarczowych w układzie przecinania. W ramach badań teoretycznych dokonano szczegółowej analizy wpływu bicia promieniowego i osiowego ostrzy piły tarczowej na efekty przecinania, przy zmiennych warunkach skrawania. Wyniki tych analiz zostały zweryfikowanie w badaniach doświadczalnych. Uzyskane zależności stanowiły...
-
[PP.17.01] INCREASED INSPIRATORY RESISTANCE AFFECTS THE CARDIAC CONTRIBUTION TO THE RELATIONSHIP BETWEEN BLOOD PRESSURE AND PIAL ARTERY PULSATION OSCILLATIONS
PublicationThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance would affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
Influence of Acute Jugular Vein Compression on the Cerebral Blood Flow Velocity, Pial Artery Pulsation and Width of Subarachnoid Space in Humans
PublicationCelem pracy jest zaprezentowanie wyników badań dotyczących oceny wpływu silnego obustronnego zwężenia żył szyjnych na amplitudę pulsacji i zmiany szerokości przestrzeni podpajęczynówkowej, prędkość przepływu mózgowego krwi, obwodowe ciśnienie krwi oraz możliwe relacje między wymienionymi parametrami.
-
Effect of Maximal Apnoea Easy-Going and Struggle Phases on Subarachnoid Width and Pial Artery Pulsation in Elite Breath-Hold Divers
PublicationPurpose: The aim of the study was to assess changes in subarachnoid space width (sas-TQ), the marker of intracranial pressure (ICP), pial artery pulsation (cc-TQ) and cardiac contribution to blood pressure (BP), cerebral blood flow velocity (CBFV) and cc-TQ oscillations throughout the maximal breath hold in elite apnoea divers. Non-invasive assessment of sas-TQ and cc-TQ became possible due to recently developed method based on...
-
Endothelial function and baroreflex sensitivity according to the oral glucose tolerance test in patients with coronary artery disease and normal fasting glucose levels
Publication -
Morphometric evaluation of the delayed cerebral arteries response to acetazolamide test in patients with chronic carotid artery stenosis using computed tomography angiography
PublicationBackground: The evidence accumulates that the response to acetazolamide test is delayed on the ipsilateral side to stenosis. However, the effect of acetazolamide beyond 30 minutes after acetazolamide administration remains unknown. The aim of this study was to assess the diameters of: anterior cerebral arteries (ACAs), middle cerebral arteries (MCAs) and posterior cerebral arteries (PCAs) before and 60 minutes after the acetazolamide...
-
Increased inspiratory resistance alters the cardiac contribution to the dynamic relationship between blood pressure and pial artery pulsation oscillations in healthy subjects
PublicationThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance will affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
Molecularly targeted nanoparticles: an emerging tool for evaluation of expression of the receptor for advanced glycation end products in a murine model of peripheral artery disease
PublicationAbstract Background: Molecular imaging with molecularly targeted probes is a powerful tool for studying the spatio-temporal interactions between complex biological processes. The pivotal role of the receptor for advanced glycation end products (RAGE) in numerous pathological processes, aroused the demand for RAGE targeted imaging in various diseases. In the study, we evaluated the use of a diagnostic imaging agent for RAGE quantification...
-
Sympathetic Activation Does Not Affect the Cardiac and Respiratory Contribution to the Relationship between Blood Pressure and Pial Artery Pulsation Oscillations in Healthy Subjects
PublicationUsing a novel method called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) and subarachnoid width (sas-TQ) in humans, we assessed the influence of sympathetic activation on the cardiac and respiratory contribution to blood pressure (BP) cc-TQ oscillations in healthy subjects. The pial artery and subarachnoid width response to handgrip...
-
An innovative panel to assess endothelial integrity of pedicled and skeletonized internal thoracic artery used as aortocoronary bypass graft: a randomized comparative histologic and immunohistochemical study
Publication -
Kazimierz Orłowski prof. dr hab. inż.
People -
Endothelial integrity of radial artery grafts harvested by minimally invasive surgery — immunohistochemical studies of CD31 and endothelial nitric oxide synthase expressions: a randomized controlled trial☆
Publication -
Differences in Expression of Genes Involved in Bone Development and Morphogenesis in the Walls of Internal Thoracic Artery and Saphenous Vein Conduits May Provide Markers Useful for Evaluation Graft Patency
Publication -
Preexisting High Expression of Matrix Metalloproteinase-2 in Tunica Media of Saphenous Vein Conduits Is Associated with Unfavorable Long-Term Outcomes after Coronary Artery Bypass Grafting
Publication -
Kierunki rozwoju inteligentnych systemów produkcyjnych
PublicationNiniejszy rozdział jest konsekwentnym rozwinieciem wybranych wniosków pracy [8]. W szczególności nadal aktualne pozostaje twierdzenie, że projektowanie Elastycznych Systemów Sterowania Produkcją nalezy do kręgu podstawowych kierunków prac badawczych o istotnym znaczeniu w nauce o inzynierii i zarządzania produkcją. Zatem po charakteryzowaniu trendów interpretacji elastyczności systemów produkcyjnych przystąpiono do analizy jej...
-
Mechatronic system for automatic inspection of circular saw teeth
PublicationArtykuł prezentuje system mechatroniczny do automatycznej oceny geometrii ostrzy pił tarczowych. Opisywany system wizyjny został zastosowany w automatycznym kontrolerze ostrzy pił tarczowych WKOPTar. Wrzeciono urządzenia posiada swój napęd sterowany bezstopniowo obrazem ostrzy i zapewnia powtarzalne pozycjonowanie ostrzy w celu przechwycenia ich obrazów, które są następnie analizowane z wykorzystaniem specjalnego oprogramowania....
-
Computer vision monitoring system for circular saw teeth.
PublicationW pracy opisano zasadę działania urządzenia do wizyjnego monitoringu ostrzy pił tarczowych tyou WKOPTar, które w sposób automatyczny dokonuje pomiarów geometrii ostrzy oraz ich położenia w pile. Przedstawiono również analizę wyników badań na bazie zarejestrowanych ostrzy badanych pił tarczowych.
-
Relationship between saw blade teeth wear and kinematics of frame sawingmachines
PublicationPrzedstawiono rezultaty badań zużycia ostrzy pił trakowych i wpływ kinematyki pilarki ramowej na rozkład zużycia poszczególnych ostrzy pił.
-
System for control of the saw tooth geometry.
PublicationW pracy przedstawiono sposób i urządzenie do sprawdzania geometrii ostrzy pił tarczowych z wykorzystaniem komputerowej rejestracji obrazów ostrzy i ich obróbką cyfrową.
-
Examination of influence of fixing circular saw on its stiffness
PublicationW artykule przedstawiono badania wpływu kształtu tarcz mocujących na sztywność ostrzy wybranych pił. Wyniki badań wykazały wykazały wpływ wielkości, kształtu i jakości powierzchni styku tarcz mocujących z korpusem piły na sztywność ostrzy piły.
-
Parameters of entry and going out of saw blade teeth during cutting with circular saw
PublicationW pracy przedstawiono analizę parametrów wejścia i wyjścia ostrzy przy przecinaniu piłami tarczowymi. Określone zostały parametry kątów natarcia i grubości warstwy skrawanej na wejściu i wyjściu ostrzy z materiału w zależności od kinematyki układu.
-
Możliwości redukcji przebiegowego zużycia paliwa przy zastosowaniu elektronicznych systemów wspomagających kierowców
PublicationElektroniczne systemy wspomagające kierowcę pomagają kierującym kontrolować sytuację na drodze, przekazują sygnały do układu hamulcowego i napędowego, rozpoznają znaki drogowe, pozwalają utrzymać odpowiedni dystans w czasie jazdy w kolumnie, a także kontrolują położenie pojazdu na pasie ruchu. Elek-troniczne systemy wspomagające kierowcę pomagają również zmniejszyć przebiegowe zużycie paliwa, poprzez odpowiednie sterowanie układem...
-
Morteza Akbari
People -
Inspection of circular saw teeth quality
PublicationDokładność geometryczna ostrzy piły tarczowej znacząco wpływa na efekty przecinania i odgrywa znaczacą rolę w ekonomice każdego zakładu przerobu drewna. Ocena jakości piły jest możliwa na bazie monitorowania dokładności geometrycznej każdego ostrza piły. Opracowany do tego celu wizyjny kontroler ostrzy pił tarczowych został przedstawiony w artykule.
-
Modelling of bio-mechanical objects: recent examples
PublicationW opracowaniu przedstawiono dwa wykorzystania modelowania bio-mechanicznego wybranych obiektów: modelowanie zachowania mięśni w układzie ramię-przedramię oraz wstępny projekt protezy dłoni przy użyciu materiałów z pamięcią kształtu. Przedstawiono wyniki badań symulacyjnych oraz opis dynamiki działania układów sterowania dla protezy dłoni oraz dla układu ramię-przedramię.
-
Wizyjny monitoring pił tarczowych
PublicationWizyjne techniki pomiarowe zastosowane do kontroli geometrii ostrzy pił tarczowych dają możliwość szybkich, skutecznych i zautomatyzowanych pomiarów, a komputerowa analiza wyników gwarantuje duże mozliwości diagnostyczne urządzenia. Monitorowanie dokładności geometrycznej ostrzy w procesie wytwarzania pił tarczowych umożliwia nie tylko ich bieżącą kontrolę, ale również daje podstawy do poprawy jakości geometrycznej produkowanych...
-
Influence of frame sawing machine´s kinematics on saw blade tooth wear.
PublicationW pracy przedstawiono wpływ kinematyki pilarki ramowej na zużycie ostrzy piłtrakowych.
-
Grzegorz Rotta dr inż.
People -
Ryszard Jan Barczyński dr hab. inż.
PeopleRyszard Jan Barczyński (b. 24 June 1957 in Gdańsk), Polish scientist, engineer, a specialist in solid state physics and electronic measurement techniques. In 1976, he obtained a high school diploma in the IV High School Tadeusz Kosciuszko in Torun. Higher education he graduated in 1981 at the Institute of Physics, Technical University of Gdansk in specialty of solid state physics, obtaining master's degree in engineering. Since...
-
Allowable values of radial runout of circular saw blade teeth
PublicationW pracy przedstawiono graniczne wartości bicia promieniowego ostrzy pił na podstawie zaproponowanych kryteriów.
-
Experimental research of circular saw blade tooth axial run-out influence on cutting effects
PublicationW pracy przedstawiono metodę pomiaru i wyniki badań doświadczalnych wpływu bicia osiowego ostrzy piły tarczowej na efekty przecinania