Publikacje
Filtry
wszystkich: 750
Katalog Publikacji
-
Long-Period Gratings and Microcavity In-Line Mach Zehnder Interferometers as Highly Sensitive Optical Fiber Platforms for Bacteria Sensing
PublikacjaSelected optical fiber sensors offer extraordinary sensitivity to changes in external refractive (RI), which make them promising for label-free biosensing. In this work the most sensitive ones, namely long-period gratings working at (DTP-LPG) and micro-cavity in-line Mach-Zehnder interferometers (µIMZI) are discussed for application in bacteria sensing. We describe their working principles and RI sensitivity when operating in water...
-
Performance of electrochemical immunoassays for clinical diagnostics of SARS-CoV-2 based on selective nucleocapsid N protein detection: Boron-doped diamond, gold and glassy carbon evaluation
PublikacjaThe 21st century has already brought us a plethora of new threats related to viruses that emerge in humans after zoonotic transmission or drastically change their geographic distribution or prevalence. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was first spotted at the end of 2019 to rapidly spread in southwest Asia and later cause a global pandemic, which paralyzes the world since then. We have designed novel...
-
Nonlinearity of electrochemical noise caused by pitting corrosion
PublikacjaPomiary wielkości statystycznych, innych niż rozkład widmowy czy amplitudowy mogą być źródłem dodatkowych informacji na temat mechanizmu powstawania szumu elektrochemicznego. Bispektrum stosowane jest do wykrycia istnienia składowych nieliniowych w badanym rejestrze szumowym. Analizowano elektrochemiczny szum prądowy rejestrowany w warunkach korozji wżerowej. Zaobserwowano zależność prąd-czas charakterystyczną dla stanu tworzenia...
-
Electrochemical performance of indium-tin-oxide-coated lossy-mode resonance optical fiber sensor
PublikacjaAnalysis of liquids performed in multiple domain, e.g., optical and electrochemical (EC), has recently focus significant attention. Our previous works have shown that a simple device based on indium-tin-oxide (ITO) coated optical fiber core may be used for optical monitoring of EC processes. At satisfying optical properties and thickness of ITO a lossy-mode resonance (LMR) effect can be obtained and used for monitoring of optical...
-
Electrochemical performance of thin free-standing boron-doped diamond nanosheet electrodes
PublikacjaIn the following work we describe preparation and the electrochemical performance of thin and free-standing heavy boron-doped diamond (BDD) nanosheets. The investigated foils were deposited on Ta substrate using microwave plasma-enhanced chemical vapor deposition technique (MPECVD). Foils of two B-dopant densities were investigated, obtained on the base of 10 k and 20 k ppm [B]/[C] ratio in the gas admixture. The obtained foils...
-
Self-assembly of vertically oriented graphene nanostructures: multivariate characterisation by Minkowski functionals and fractal geometry
PublikacjaThe enormous self-assembly potential that graphene and its derived layered materials offer for responding to the contemporary environmental challenges has made it one of the most investigated materials. Hence, tuning its extraordinary properties and understanding the effect at all scales is crucial to tailoring highly customised electrodes. Vertically oriented graphene nanostructures, also known as carbon nanowalls (CNWs), due...
-
Combined chemoresistive and in situ FTIR spectroscopy study of nanoporous NiO films for light-activated nitrogen dioxide and acetone gas sensing
PublikacjaThe chemoresistive sensor response of nanoporous NiO films prepared by advanced gas deposition was investigated by combined resistivity and in situ FTIR spectroscopy, with and without simultaneous light illumination, to detect NO2 and acetone gases. The sensitivity towards NO2 increased dramatically under UV irradiation employing 275 nm light. Improved sensitivity was observed at an elevated temperature of 150 °C. In situ FTIR...
-
Tuning the Laser-Induced Processing of 3D Porous Graphenic Nanostructures by Boron-Doped Diamond Particles for Flexible Microsupercapacitors
PublikacjaCarbon (sp3)-on-carbon (sp2) materials have the potential to revolutionize fields such as energy storage and microelectronics. However, the rational engineering and printing of carbon-on-carbon materials on flexible substrates remains a challenge in wearable electronics technology. This study demon-strates the scalable fabrication of flexible laser-induced graphene (LIG)-boron doped diamond nanowall (BDNW) hybrid nanostructures...
-
Integration of protein tethering in a rapid and label-free SERS screening platform for drugs of abuse
PublikacjaSurface enhanced Raman spectroscopy (SERS) has emerged as a promising technique for the rapid and ultrasensitive detection of molecular species such as drugs of abuse in biofluids. Yet, it remains a significant challenge to create a viable screening tool for multiple drug classes, owing to the lack of affinity of certain species for the SERS substrate and to the matrix interference in complex media. Here we report a protein tethering...
-
Use of optical skin phantoms for preclinical evaluation of laser efficiency for skin lesion therapy
PublikacjaSkin lesions are commonly treated using laser heating. However, the introduction of new devices into clinical practice requires evaluation of their performance. This study presents the application of optical phantoms for assessment of a newly developed 975-nm pulsed diode laser system for dermatological purposes. Such phantoms closely mimic the absorption and scattering of real human skin (although not precisely in relation to...
-
Detection of random transients caused by pitting corrosion
PublikacjaProces korozyjny może być badany za pomocą techniki szumu elektrochemicznego. Szum obserwowany jest jako fluktuacje prądowe i napięciowe w trójelektrodowym układzie pomiarowym. W celu stwierdzenia obecności korozji wżerowej wykonana została detekcja charakterystycznych sygnałów. Opracowany został algorytm oparty na analizie lokalnych zmian w spektrogramie rejestru prądowego. Spektrogram uzyskany został za pomocą krótkoczasowej...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublikacjaIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
Optical Detection of Ketoprofen by Its Electropolymerization on an Indium Tin Oxide-Coated Optical Fiber Probe
PublikacjaIn this work an application of optical fiber sensors for real-time optical monitoring of electrochemical deposition of ketoprofen during its anodic oxidation is discussed. The sensors were fabricated by reactive magnetron sputtering of indium tin oxide (ITO) on a 2.5 cm-long core of polymer-clad silica fibers. ITO tuned in optical properties and thickness allows for achieving a lossy-mode resonance (LMR) phenomenon and it can be...
-
Preparation and Characterization of Microsphere ZnO ALD Coating Dedicated for the Fiber-Optic Refractive Index Sensor
PublikacjaWe report the fabrication of a novel fiber-optic sensor device, based on the use of a microsphere conformally coated with a thin layer of zinc oxide (ZnO) by atomic layer deposition (ALD), and its use as a refractive index sensor. The microsphere was prepared on the tip of a single-mode optical fiber, on which a conformal ZnO thin film of 200 nm was deposited using an ALD process based on diethyl zinc (DEZ) and water at 100 °C....
-
Tailoring properties of indium tin oxide thin films for their work in both electrochemical and optical label-free sensing systems
PublikacjaThis work is devoted to the identification properties of indium tin oxide (ITO) thin films responsible for their possible application in combined optical and electrochemical label-free sensing systems offering enhanced functionalities. Since any post-processing would make it difficult to identify direct relation between deposition parameters and properties of the ITO films, especially when deposition on temperature-sensitive substrates...
-
Electrochemical degradation of textile dyes in a flow reactor: effect of operating conditions and dyes chemical structure
PublikacjaIn this study, electrochemical oxidation of five azo dyestuffs (Yellow D-5GN, Red D-B8, Ruby F-2B, Blue D-5RN, Black DN), that are widely used in the textile industry, was investigated in a flow reactor. BDD electrode with a high boron doping level (C/B = 10 000) was prepared and used. Two configurations of reactor were considered, i.e., one with the undivided cell, and the other with the cell divided by anodic and cathodic compartments....
-
Single-step grown boron doped nanocrystalline diamond-carbon nanograss hybrid as an efficient supercapacitor electrode
PublikacjaDirect synthesis of nano-structured carbon hybrid consisting of vertically aligned carbon nanograss on top of boron-doped nanocrystalline diamond is demonstrated and the carbon hybrid is further applied as an electrode material for the fabrication of supercapacitor. The hybrid film combines the dual advantages of sp2 (carbon nanograss) and sp3 (nanocrystalline diamond) bonded carbon, possessing not only the excellent electrical...
-
Analysis of an Attenuator Artifact in an Experimental Attack by Gunn–Allison–Abbott Against the Kirchhoff-Law–Johnson-Noise (KLJN) Secure Key Exchange System
PublikacjaA recent paper by Gunn–Allison–Abbott (GAA) [L. J. Gunn et al., Scientific Reports 4 (2014) 6461] argued that the Kirchhoff-law–Johnson-noise (KLJN) secure key exchange system could experience a severe information leak. Here we refute their results and demonstrate that GAA’s arguments ensue from a serious design flaw in their system. Specifically, an attenuator broke the single Kirchhoff-loop into two coupled loops, which is an...
-
Time-domain measurement methods for R, L and C sensors based on aversatile direct sensor-to-microcontroller interface circuit
PublikacjatIn the paper new time-domain measurement methods for determining values of resistive (R), inductive(L) and capacitive (C) sensors based on a versatile direct sensor-to-microcontroller interface for microcon-trollers with internal analog-to-digital converters (ADCs) and analog comparators (ACs) are presented.The interface circuit consists of a reference resistor Rrworking as a voltage divider, a given R, L or C sensorand a microcontroller...
-
Nucleation and growth of CVD diamond on fused silica optical fibres with titanium dioxide interlayer
PublikacjaNucleation and growth processes of thin diamond films on fused silica optical fibres have been investigated. Fibres were coated with diamond film using microwave plasma enhanced chemical vapour deposition (µPE CVD) system. Since the growth of diamond on the fused silica glass requires high seeding density, two types of glass pre-treatment were applied: titanium dioxide (TiO2) interlayer deposition and sonication in nanodiamond...
-
Growth and Isolation of Large Area Boron‐Doped Nanocrystalline Diamond Sheets: A Route toward Diamond‐on‐Graphene Heterojunction
PublikacjaMany material device applications would benefit from thin diamond coatings, but current growth techniques, such as chemical vapor deposition (CVD) or atomic layer deposition require high substrate and gas‐phase temperatures that would destroy the device being coated. The development of freestanding, thin boron‐doped diamond nanosheets grown on tantalum foil substrates via microwave plasma‐assisted CVD is reported. These diamond...
-
Study on Combined Optical and Electrochemical Analysis Using Indium-tin-oxide-coated Optical Fiber Sensor
PublikacjaThe growing needs for fast and reliable sensing devices stimulate development of new technological solutions. In this work a new multi-domain sensing method is demonstrated where optical sensing device has been applied to enhance amount of data received during electrochemical analysis. Thin, optically transparent, high-refractive-index, and electrically conductive indium tin oxide (ITO) film was deposited using magnetron sputtering...
-
Measurement of complex refractive index of human blood by low-coherence interferometry
PublikacjaIn this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherencei nterferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum...
-
Characterization of Optical and Electrical Properties of Transparent Conductive Boron-Doped Diamond thin Films Grown on Fused Silica
PublikacjaA conductive boron-doped diamond (BDD) grown on a fused silica/quartz has been investigated. Diamond thin films were deposited by the microwave plasma enhanced chemical vapor deposition (MW PECVD). The main parameters of the BDD synthesis, i.e. the methane admixture and the substrate temperature were investigated in detail. Preliminary studies of optical properties were performed to qualify an optimal CVD synthesis and film parameters...
-
Formation of Highly Conductive Boron-Doped Diamond on TiO2 Nanotubes Composite for Supercapacitor or Energy Storage Devices
PublikacjaIn the present paper, we report the phenomena of the formation of the novel composite nanostructures based on TiO2 nanotubes (NTs) over-grown by thin boron-doped diamond (BDD) film produced in Microwave Plasma Enhanced Chemical Vapor Deposition (PE MWCVD). The TiO2 nanotube array overgrown by boron-doped diamond immersed in 0.1 M NaNO3 can deliver high specific capacitance of 7.46 mF cm−2. The composite electrodes were characterized...
-
Optical Magnetometry Based on Nanodiamonds with Nitrogen-Vacancy Color Centers
PublikacjaNitrogen-vacancy color centers in diamond are a very promising medium for many sensing applications such as magnetometry and thermometry. In this work, we study nanodiamonds deposited from a suspension onto glass substrates. Fluorescence and optically detected magnetic resonance spectra recorded with the dried-out nanodiamond ensembles are presented and a suitable scheme for tracking the magnetic-field value using a continuous...
-
A complete impedance analysis of electrochemical cells used as energy sources
PublikacjaA comprehensive description of impedance ofelectrochemical systems has been presented, along withthe assumptions of the method used. In this method, amultisinusoidal current excitation signal is used. Thechanges of potential of both the electrodes and thepotential difference between these electrodes are allregistered simultaneously as a function of time. Theproposed method offers the possibility of separatelydetermining the instantaneous...
-
Stress Monitoring System for Individuals with Autism Spectrum Disorders
PublikacjaIn this article, a stress monitoring system tailored for individuals with Autism Spectrum Disorders (ASD) and developed for the educational institution is presented. People with ASD face problems with effective stress management due to their high self-perceived levels of stress, poor ability to cope with it, and dificulties with the accurate detection of the source of stress. Consistently, being able to measure stress appears to...
-
Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization
PublikacjaThe number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its...
-
In vivo imaging of the human eye using a two-photon excited fluorescence scanning laser ophthalmoscope
PublikacjaBACKGROUND. Noninvasive assessment of metabolic processes that sustain regeneration of human retinal visual pigments (visual cycle) is essential to improve ophthalmic diagnostics and to accelerate development of new treatments to counter retinal diseases. Fluorescent vitamin A derivatives, which are the chemical intermediates of these processes, are highly sensitive to UV light; thus, safe analyses of these processes in humans...
-
Detection of Denatonium Benzoate (Bitrex) Remnants in Noncommercial Alcoholic Beverages by Raman Spectroscopy
PublikacjaIllegal alcoholic beverages are often introduced into market using cheap technical alcohol, which is contaminated by denatonium benzoate (Bitrex) of very small concentration. Bitrex is the most bitter chemical compound and has to be removed before alcohol consumption. The home-made methods utilize sodium hypochlorite to disintegrate particles of denatonium benzoate in alcohol and to remove bitter taste before trading. In this experimental...
-
Determination of refractive index dispersion using fiber-optic low-coherence Fabry–Perot interferometer: implementation and validation
PublikacjaWe present the implementation and validation of low-coherence Fabry–Perot interferometer for refractive index dispersion measurements of liquids. A measurement system has been created with the use of four superluminescent diodes with different optical parameters, a fiber-optic coupler and an optical spectrum analyzer. The Fabry–Perot interferometer cavity has been formed by the fiber-optic end and mirror surfaces mounted on a micromechanical...
-
Tribo-Environment Dependent Chemical Modification of Sliding Interfaces in Ultrananocrystalline Diamond Nanowall Film: A Correlation with Friction and Wear
PublikacjaTribological properties of ultrananocrystalline diamond nanowall (UNCD NW) films were investigated quantitatively in three different and controlled tribo-environmental conditions, proposing the passivation and graphitization mechanisms. However, these mechanisms are rather complicated and possibly can be understood in well-controlled tribological conditions. It was shown that the friction and wear of these films were high in highPage 1...
-
Effects of UV light irradiation on fluctuation enhanced gas sensing by carbon nanotube networks
PublikacjaThe exceptionally large active surface-to-volume ratio of carbon nanotubes makes it an appealing candidate for gas sensing applications. Here, we studied the DC and low-frequency noise characteristics of a randomly oriented network of carbon nanotubes under NO2 gas atmosphere at two different wavelengths of the UV light-emitting diodes. The UV irradiation allowed to sense lower concentrations of NO2 (at least 1 ppm) compared to...
-
Support for Employees with ASD in the Workplace Using a Bluetooth Skin Resistance Sensor–A Preliminary Study
PublikacjaThe application of a Bluetooth skin resistance sensor in assisting people with Autism Spectrum Disorders (ASD), in their day-to-day work, is presented in this paper. The design and construction of the device are discussed. The authors have considered the best placement of the sensor, on the body, to gain the most accurate readings of user stress levels, under various conditions. Trial tests were performed on a group of sixteen...
-
Fabrication and characterization of boron-doped nanocrystalline diamond-coated MEMS probes
PublikacjaFabrication processes of thin boron-doped nanocrystalline diamond (B-NCD) films on silicon-based micro- and nano-electromechanical structures have been investigated. Nanocrystalline boron doped -diamond (B-NCD) films were deposited using Microwave Plasma Assisted Chemical Vapour Deposition (MW PA CVD) method. The variation of B-NCD morphology, structure and optical parameters were particularly investigated. The use of truncated...
-
Towards high quality ITO coatings: the impact of nitrogen admixture in HiPIMS discharges
PublikacjaThe paper reports controlled deposition of optically transparent and electrically conductive ITO films prepared by a combination of rf (13.56 MHz) and High Power Impulse Magnetron Sputtering (HiPIMS) systems without any post deposition thermal treatment/annealing. It is shown that (i) reactive admixture of N2 gas to the process and (ii) pressure in the deposition chamber enable to optimize optical properties of ITO films. Furthermore,...
-
Multisine impedimetric probing of biocatalytic reactions for label-free detection of DEFB1 gene: How to verify that your dog is not human?
PublikacjaAlbert is a dog (Canis familiaris), but he does not realize this. Albert loves human food (and beer), watching movies on the internet, sleeping in bed, and more. But he should not do all these things. To convince him that, we have desinged a test procedure. The DEFB1 gene is unique to human species. Detecting its presence from saliva and in short periods may offer an advantage in the field of forensic medicine, and influence Albert’s...
-
Helium-assisted, solvent-free electro-activation of 3D printed conductive carbon-polylactide electrodes
PublikacjaFused filament fabrication is one of the most rapidly developing 3D printing techniques, with numerous applications, including in the field of applied electrochemistry. Here, the utilisation of conductive carbon black polylactic acid (CB-PLA) for 3D printouts is the most promising. To use CB-PLA as an electrode material, an activation process must be performed, removing the polymer matrix and uncovering the electrically conductive...
-
Low-power microwave-induced fabrication of functionalised few-layer black phosphorus electrodes: A novel route towards Haemophilus Influenzae pathogen biosensing devices
PublikacjaIn this paper, various passivation schemes were applied at few-layer black phosphorus (FLBP) to achieve covalent functionalisation with 4-azidobenzoic acid, improving its electrochemical response intended for analytical and biosensing applications. The thermal and microwave assisted modification procedures in toluene and dime-thylformamide resulted in high reversibility of reactions on functionalised FLBP using a ferricyanide/ferrocya-nide...
-
Experimental results of full scattering profile from finger tissue-like phantom
PublikacjaHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. We suggest a new optical method for sensing physiological tissue state, based on the collection of the ejected light at all exit angles, to receive the full scattering profile. We built a unique set-up for noninvasive encircled measurement. We use a laser, a photodetector and finger tissues-mimicking phantoms presenting different optical...
-
Predictions of cervical cancer identification by photonic method combined with machine learning
PublikacjaCervical cancer is one of the most commonly appearing cancers, which early diagnosis is of greatest importance. Unfortunately, many diagnoses are based on subjective opinions of doctors—to date, there is no general measurement method with a calibrated standard. The problem can be solved with the measurement system being a fusion of an optoelectronic sensor and machine learning algorithm to provide reliable assistance for doctors...
-
Optimization of a Fabry-Perot Sensing Interferometer design for an optical fiber sensor of hematocrit level
PublikacjaContinuous measurement of the hemato crit level in blo o d can p otentially b e p erformed using optical bre sensors. The FabryPerot interferometric sensors are a promising candidate in this application. The most imp ortant step in the design of the sensor is design of the sensing interferometer. Adequate cavity length and high interference contrast are two most imp ortant requirements in this application. The design metho d of...
-
Fault diagnosis of analog piecewise linear circuits based on homotopy
PublikacjaArtykuł opisuje weryfikację metodą diagnostyki analogowych układów odcinkowo-liniowych opartą na podejściu homotopijnym. Homotopia przekształca jedną funkcję f(x) w inną funkcję g(x) poprzez zmianę parametru homotopii tî[0,1]. Ścieżka homotopijna pokazuje drogę od punktu x0 z dziedziny funkcji f(x) do odpowiadającego mu punktu x* funkcji g(x). Idea metody zakłada wykorzystanie funkcji f(x) do opisu diagnozowanego układu w stanie...
-
Tuning of the Electrochemical Properties of Transparent Fluorine-doped Tin Oxide Electrodes by Microwave Pulsed-plasma Polymerized Allylamine
PublikacjaWe report here the dry, one-step, and low-temperature modification of FTO surfaces using pulsed plasma polymerization of allylamine (PPAAm). PPAAm/FTO surfaces were characterized by X-ray photoelectron spectroscopy, spectroscopic ellipsometry, and contact angles to understand the morphological, structural, and optical properties. FTO were coated with a very thin layer of adherent cross-linked, pinhole-, and additive-free allylamine...
-
Analytical fluctuation enhanced sensing by resistive gas sensors
PublikacjaResistance fluctuations across polarised resistive gas sensors were studied in detail to evaluate sensor working conditions for detecting methane and ammonia at various concentrations. The 1/f noise component typically dominates other noise sources up to a few kHz and can be utilised to improve gas selectivity when compared with measurements of the sensor DC resistance. The Arrhenius plot was created and the activation energy for...
-
Determination of Chemical Oxygen Demand (COD) at Boron-doped Diamond (BDD) Sensor by Means of Amperometric Technique
PublikacjaA boron-doped diamond (BDD) sensor was proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Thin boron doped diamond active sensor layer was deposited on Si wafer and glassy carbon substrate by Microwave Plasma Enhanced Chemical Vapor Deposition (MW PE CVD). The structure of BDD was confirmed by Raman spectra analysis. Broad Raman bands centered at 482 cm-1 and 1219 cm-1 are typical...
-
Blood equivalent phantom vs whole human blood, a comparative study
PublikacjaPreclinical research of biomedical optoelectronic devices is often performed with the use of blood phantoms — a simpli¯ed physical model of blood. The aim of this study is the comparison and distinction between blood phantoms as well as whole human blood measurements. We show how the use of such phantoms may in°uence the incorrect interpretation of measured signal. On the other hand, we highlight how the use of blood phantoms enables...
-
Gas selectivity enhancement by sampling-and-hold method in resistive gas sensors
PublikacjaCommercial resistive gas sensors exhibit various sensitivity to numerous gases when working at different elevated temperatures. That effect is due to a change in velocity of adsorption and desorption processes which can be modulated by temperature. Thus, to reach better selectivity of gas detection, we propose to apply a known method (called the sampling-and-hold method) of cooling down the gas sensor in the presence of the investigated...
-
Doped Nanocrystalline Diamond Films as Reflective Layers for Fiber-Optic Sensors of Refractive Index of Liquids
PublikacjaThis paper reports the application of doped nanocrystalline diamond (NCD) films—nitrogen-doped NCD and boron-doped NCD—as reflective surfaces in an interferometric sensor of refractive index dedicated to the measurements of liquids. The sensor is constructed as a Fabry–Pérot interferometer, working in the reflective mode. The diamond films were deposited on silicon substrates by a microwave plasma enhanced chemical vapor deposition...