Uncertainty of antioxidant profiling in complex mixtures using liquid chromatography involving post-column derivatisation
Abstrakt
The main goal of this paper is to discuss the problems associated with antioxidant profiling in complex samples using a high-throughput HPLC system coupled with post-column derivatisation reactor. Based on the experimental data reported in the literature, we demonstrated that improper optimisation of temperature and/or pH assay conditions performed using an on-line derivatisation reactor may substantially change the antioxidant peaks ratio of targeted phytochemical compounds. It has been found that despite the relatively high stability of flavonoids at high temperature and under binary mobile phase HPLC conditions, the reaction of target compounds with common ABTS, FCR and DPPH radicals at elevated regions (particularly above 100 °C) dramatically changes their antioxidant activity values expressed, for example, as TEAC (Trolox equivalent antioxidant capacity) parameters. In principle, separation and detection processes of antioxidant profiling assay must not significantly affect the antioxidant activity of target compounds. In the case of foods eaten by humans or animals, critical experimental parameters such as pH and temperature concerning interaction of target analytes with derivatisation reagent should be as close as possible to the real physiological values.
Cytowania
-
3
CrossRef
-
0
Web of Science
-
3
Scopus
Autorzy (3)
Cytuj jako
Pełna treść
pełna treść publikacji nie jest dostępna w portalu
Słowa kluczowe
Informacje szczegółowe
- Kategoria:
- Publikacja w czasopiśmie
- Typ:
- artykuł w czasopiśmie wyróżnionym w JCR
- Opublikowano w:
-
JOURNAL OF FOOD COMPOSITION AND ANALYSIS
nr 33,
wydanie 2,
strony 216 - 219,
ISSN: 0889-1575 - Język:
- angielski
- Rok wydania:
- 2014
- Opis bibliograficzny:
- Głód B., Kamiński M., Zarzycki P.: Uncertainty of antioxidant profiling in complex mixtures using liquid chromatography involving post-column derivatisation// JOURNAL OF FOOD COMPOSITION AND ANALYSIS. -Vol. 33, iss. 2 (2014), s.216-219
- DOI:
- Cyfrowy identyfikator dokumentu elektronicznego (otwiera się w nowej karcie) 10.1016/j.jfca.2013.02.012
- Weryfikacja:
- Politechnika Gdańska
wyświetlono 148 razy
Publikacje, które mogą cię zainteresować
Quality control of cheese samples for the presence of natamycin preservative – A natural deep eutectic solvent (NADES) based extraction coupled with HPLC
- H. Haq,
- N. Altunay,
- M. Tuzen
- + 1 autorów