Nie znaleźliśmy wyników w zadanych kryteriach!
Ale mamy wyniki w innych katalogach.Filtry
wszystkich: 1892
-
Katalog
- Publikacje 1272 wyników po odfiltrowaniu
- Czasopisma 19 wyników po odfiltrowaniu
- Konferencje 37 wyników po odfiltrowaniu
- Osoby 39 wyników po odfiltrowaniu
- Wynalazki 1 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Kursy Online 16 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 505 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: END-PLATE JOINT
-
Shell model of multiple-row moment I-section end-plate joint
PublikacjaThe paper deals with a problem of application of shell elements in the models of multiple-row moment end-plate connections. The extended connection of I-section with a cross-section W760x265x220 made of steel S355 was analyzed. Comparison analysis of FEM, complex volume and shell models has been done. Three cases with different end-plate thickness: 14, 18 and 36 mm were analyzed and compared with the reference results. Comparison...
-
Medially positioned plate in first metatarsophalangeal joint arthrodesis
PublikacjaObjective The purpose of this study was to biomechanically compare the stability of first metatarsophalangeal (MTP1) joint arthrodesis with dorsally and medially positioned plates. Methods A physical model of the MTP1 joint consists of printed synthetic bones, a titanium locking plate and screws. In the experiments, samples with dorsally and medially positioned plates were subjected to loading of ground load character in a universal...
-
Moment resistance of I-section end-plate roof girder splices; a case study
PublikacjaThis article deals with the problem of determining the resistance of end-plate connections. A nonlinear FEM model of the joint was constructed in order to predict its carrying capacity. A standard code procedure was done as well. The analyses have been done to assess atypical end-plate joints designed and constructed as a part of roof structures.
-
Effect of lag screw on stability of first metatarsophalangeal joint arthrodesis with medial plate
PublikacjaBackground: First metatarsophalangeal joint (MTP-1) arthrodesis is a commonly performed procedure in the treatment of disorders of the great toe. Since the incidence of revision after MTP-1 joint arthrodesis is not insignificant, a medial approach with a medially positioned locking plate has been proposed as a new technique. The aim of the study was to investigate the effect of the application of a lag screw on the stability and...
-
RMS-based damage identification in adhesive joint between concrete beam and steel plate using ultrasonic guided waves
PublikacjaAdhesive joints have numerous applications in many branches of industry, such as civil engineering, automotive, aerospace and shipbuilding. As with most structural elements, adhesive joints can experience any damage mechanism, which induces the need for diagnostic testing. Ultrasonic waves are widely used for non-destructive inspection of many structures and their elements, including adhesive joints. Guided wave propagation method...
-
Comparative analysis of mechanical conditions in bone union following first metatarsophalangeal joint arthrodesis with varied locking plate positions: A finite element analysis
PublikacjaFirst metatarsophalangeal joint arthrodesis is a typical medical treatment performed in cases of arthritis or joint deformity. The gold standard for this procedure is arthrodesis stabilisation with the dorsally positioned plate. However, according to the authors’ previous studies, medially positioned plate provides greater bending stiffness. It is worth to compare the mechanical conditions for bone formation in the fracture callus...
-
Bending test results of first metatarsophalangeal joint after arthrodesis with medially or dorsally positioned locking plate and lag screw.
Dane BadawczeThe Dataset contains the results of the bending test of first metatarsophalangeal (MTP1) joint specimens after arthrodesis.
-
Displacements of bones during bending test of first metatarsophalangeal joint after arthrodesis with medially or dorsally positioned locking plate and lag screw.
Dane BadawczeThe Dataset contains the values of displacements of bone control points during the bending test of first metatarsophalangeal (MTP1) joint specimens after arthrodesis.
-
Lamb wave propagation in a single lap adhesive joint
PublikacjaThe aim of the paper is the analysis of Lamb wave propagation in adhesive joints. The research was performed on a single lap adhesive joint of two steel plates. Two types of joints, namely an intact and with defect were considered. In experimental investigations the condition assessment of the joint was performed with the use of antisymmetric Lamb waves excited by a plate piezo actuators and measured by a laser vibrometer. Numeri-cal...
-
CAPABILITY OF IDENTIFYING AND PREDICTING THE TECHNICAL CONDITION OF PLATE HEAT EXCHANGERS IN OPERATION
PublikacjaThe paper presents a test stand for plate heat exchangers, allowing to identify the technical condition and to predict durability of the heat exchangers used aboard the sea-going ships: ”Oceanograf”, ”Władysław Orkan”and a passenger-car ferry, under the condition that they are of the same type and manufactured by the same company. In the first part three different installations with plate heat exchangers in the engine rooms...