Filtry
wszystkich: 9839
wybranych: 987
-
Katalog
- Publikacje 6699 wyników po odfiltrowaniu
- Czasopisma 45 wyników po odfiltrowaniu
- Konferencje 13 wyników po odfiltrowaniu
- Osoby 146 wyników po odfiltrowaniu
- Wynalazki 22 wyników po odfiltrowaniu
- Projekty 52 wyników po odfiltrowaniu
- Laboratoria 3 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Aparatura Badawcza 7 wyników po odfiltrowaniu
- Kursy Online 161 wyników po odfiltrowaniu
- Wydarzenia 13 wyników po odfiltrowaniu
- Dane Badawcze 2677 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: SYSTEM TRANKINGOWY TETRA
-
Study of the influence of the presence of Dr fimbriae on the adherence of cells of the recombinant Escherichia coli strain: BL21(DE3)/pACYCpBAD to glass in a dynamic system
Dane BadawczeThe attachment of bacteria begins the process of surface colonization, called biofilm development, characterized by a number of physicochemical and molecular interactions. Adherence to inert surfaces typically involves nonspecific interactions, whereas adherence to biological surfaces is associated with specific ligand-receptor interactions. In this...
-
Study of the influence of the presence of Dr fimbriae on the adherence of cells of the recombinant Escherichia coli strain: BL21(DE3)/pCC90 to glass in a dynamic system
Dane BadawczeThe attachment of bacteria begins the process of surface colonization, called biofilm development, characterized by a number of physicochemical and molecular interactions. Adherence to inert surfaces typically involves nonspecific interactions, whereas adherence to biological surfaces is associated with specific ligand-receptor interactions. In this...
-
Study of the influence of the presence of Dr fimbriae on the adherence of cells of the recombinant Escherichia coli strain: BL21(DE3)/pACYCpBAD to polystyrene in a dynamic system
Dane BadawczeThe attachment of bacteria begins the process of surface colonization, called biofilm development, characterized by a number of physicochemical and molecular interactions. Adherence to inert surfaces typically involves nonspecific interactions, whereas adherence to biological surfaces is associated with specific ligand-receptor interactions. In this...
-
Euilibrium composition of CH4-CO2-CO-H2-H2O-C system under various compositions syngas methanation with 10% water vapour introduced
Dane BadawczeThe equilibrium compositions of CH4, CO2, CO, H2, H2O and C under the methanation reaction of various syngas mixtures (different CO/H2 ratio) were supplied with this dataset
-
Euilibrium composition of CH4-CO2-CO-H2-H2O-C system under various compositions syngas methanation with 20vol.% water vapour introduced
Dane BadawczeThe equilibrium compositions of CH4, CO2, CO, H2, H2O and C under the methanation reaction of various syngas mixtures (different CO/H2 ratio) were supplied with this dataset
-
Euilibrium composition of CH4-CO2-CO-H2-H2O-C system under various compositions syngas methanation with 30vol.% water vapour introduced
Dane BadawczeThe equilibrium compositions of CH4, CO2, CO, H2, H2O and C under the methanation reaction of various syngas mixtures (different CO/H2 ratio) were supplied with this dataset
-
Reliability data safety instrumented systems SIS from the functional safety analysis example critical instalation
Dane BadawczeThe dataset represents the results of an example of functional safety analysis systems is presented below. It is based on a control system, which consists of some basic components like sensors, programmable logic controllers and valves. It is a part of petrochemical critical installations. The communication between sensor logic controllers and actuators...
-
Analytical and reliability data from the real-time simulator biogas plant
Dane BadawczeThe dataset represents the results of biogas plant simulation. The described plant is an agricultural biogas system, which can produce electrical energy with power estimated up to 1070 kW and heat energy that can reach 1200 kW simultaneously.
-
Dual drive control under SVPWM, experimental results
Dane BadawczeThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The analysis includes the behaviour of the drive system, examining the dynamic system response to speed and angle changes, and encompassing data...
-
Structure of the register of immovable monuments in terms of the typological groups of large-scale monuments by voivodeship - comparison of 2016 and 2024
Dane BadawczeThe following dataset compares the structure of the register of immovable monuments in Poland regarding the typological groups of large-scale monuments by voivodeship for 2016 and 2024. The typological groups of large-scale monuments included:
-
Numerical metadata of a microchamber with bacteria
Dane BadawczeSelected results in the form of graphs and a diagram of the analysed system. The metadata shows in sequence: 1) Temperature distribution inside fluidic chamber (=0.8, h=100) after 190s of irradiationTemperature distribution inside fluidic chamber (=0.8, h=100) after 190s of irradiation; 2) Maximum temperature profile in the fluidic chamber during the...
-
Communication methods at selected private universities in Gdańsk, Sopot and Gdynia in 2010
Dane BadawczeA university, including a private one, is an organization serving the environment. Therefore, a necessary condition (especially in today's market situation) is the development of cooperation between universities and the environment. Creating mutual relations between universities with the environment, belongs to an important area of activity of this...
-
Structural investigations of the Al2O3 ultra thin films
Dane BadawczeUltra-thin layers of Al2O3 were deposited by atomic layer deposition (ALD) (Beneq TFS 200 ALD system). This method provides precise thickness control down to a single atomic layer. The precursors used were trimethylaluminum (Sigma-Aldrich) and purified water. The deposition of the atomic layer was carried out at 200 °C. Samples with a thickness of 2...
-
Long-term measurement of physiological parameters - adult (120 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters.
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (60 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - adult (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
AeroSense Measurements: Aventa AV-7 Taggenberg Winter 2022-2023 Campaign
Dane BadawczeData from field tests of Aerosesne measurement system installed on Avneta AV-7 wind turbine, located in Taggenberg (ZH), Switzerland. Dataset contains intermittent 10 minute long measurement sessions from 40 barometers, and IMU system installed on the wind turbine blade at r/R = 0.740625. The measurement campaign was performed between 01.DEC.2022 and...
-
Long-term measurement of physiological parameters (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 110 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 3 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 6th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 5 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 1 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 12. series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (4h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 11. series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 2 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 7th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 10th series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (150 minutes) 1 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 150 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (13h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (13 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 9th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 4 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 8th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (10h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (10 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 3 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Measurement of the temperature change of PVCP tissue phantom illuminated by dermatological laser 1.series
Dane BadawczeApplication of laboratory set-up for characterization of thermal properties of optical tissue phantoms during laser irradiation is presented. The produced system utilizes a thermographic camera VIGOcam v50 and a dermatological laser system with a 975 nm diode laser module. The set-up was used to perform measurements of the temporal and spatial temperature...
-
Long-term measurement of physiological parameters - a teenager (9h and 20min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (9 hours and 20 minutes) measurement of physiological parameters was performed on...
-
Detailed results of shaping personnel risk factors in enterprise A
Dane BadawczeThe data presents the shape of all the researched personnel risk factors in the A enterprise (which was tested by the author). Further considerations should be started with the presentation of the synthesis of the obtained results, which is presented in this research data.
-
Fire Weather Index data for Poland (March – September 2019) based on high-resolution Weather Research and Forecasting Model
Dane BadawczeThis dataset contains forecasted FWI indices calculated for the period: March 1 - September 30, 2019, based on the meteorological fields derived from the Weather Research and Forecasting Model (WRF) ver. 4.2.1. For each day FWI data with the forecast range equal 24 and 48 hour were stored in GeoTIFF files. In addition, soil moisture and temperature...
-
Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser.
Dane BadawczeApplication of laboratory set-up for characterisation of thermal properties of optical tissue phantoms during laser irradiation is presented. The produced system utilizes thermographic camera VIGOcam v50 and dermatological laser system with a 975 nm diode laser module. The set-up was used to perform measurements of the temporal and spatial temperature...
-
Maximum temperature of 0.5-W infrared laser-Illuminated gold nanorod platforms
Dane BadawczeData concern a system consisted of two pieces of borosilicate glass surrounded by air and joined together by a transparent glue, which is to serve as a thermal transducer. On the top and bottom sides of the smaller piece, gold nanorods are dislocated. Glass is prepared here due to its high transparency, facilitating heat to be produced within the system....
-
Optical Parameters Stability Over Time of Porous Phantoms Mimicking Tissues
Dane BadawczeOptical phantoms are used to validate optical measurement methods. The stability of their optical parameters over time allows them to be used and stored over long-term periods while maintaining their optical parameters. The aim of the presented research was to investigate the stability of fabricated porous phantoms, which can be used as a lung phantom...
-
Data obtained by computation for X-ray imaging of grating without magnification using oriented Gaussian beams
Dane BadawczeThe propagation of X-ray waves through an optical system consisting of grating and X-ray refractive lenses is considered. In this approach, the propagating wave is represented as a superposition of the oriented Gaussian beams. The direction of wave propagation in each Gaussian beam is consistent with the local propagation direction of the X-ray wavefront.