Wyniki wyszukiwania dla: CURRENT SOURCE INVERTER (CSI)
-
Current Source Inverter Fed Drive
PublikacjaThis book covers three-phase and multiphase (more than three-phase) motor drives including their control and practical problems faced in the field (e.g., adding LC filters in the output of a feeding converter), are considered. The new edition contains links to Matlab®/Simulink models and PowerPoint slides ideal for teaching and understanding the material contained within the book. Readers will also benefit from the inclusion of: A...
-
Predictive Current Control of Voltage-Source Inverter.
PublikacjaW artykule przedstawiono regulator prądu stojana silnika asynchronicznego z predykcją napiecia wyjściowego. Rozważono aspekty praktycznej realizacji algorytmu w układzie z procesorem sygnałowym związane z opóźnieniami pomiaru prądu przy zastosowaniu przetwornika A/C. Układ zrealizowano praktycznie przy wykorzystaniu układu FPGA. W pracy zamieszczono wyniki badań symulacyjnychi eksperymentalnych.
-
Sensorless Control of Induction Machine Supplied by Current Source Inverter
PublikacjaThe paper describes the voltage control technique of induction machines supplied by a current source inverter. The control system is based on proposed new multi-scalar variables, which are named “r.” The control system contains the output filter capacitor's model. In the sensorless control system the Z type backstepping speed observer was applied. The mathematical dependences are confirmed by simulation and experimental research.
-
Sensorless Control of Induction Motor Supplied by Current Source Inverter
Publikacja -
Nonlinear Control of a Doubly Fed Generator Supplied by a Current Source Inverter
PublikacjaNowadays, wind turbines based on a doubly fed induction generator (DFIG) are a commonly used solution in the wind industry. The standard converter topology used in these systems is the voltage source inverter (VSI). The use of reverse-blocking insulated gate bipolar transistor (RB-IGBT) in the current source inverter topology (CSI), which is an alternative topology, opens new possibilities of control methods. This paper presents...
-
Trans-Z-source-like inverter with built-in DC current blocking capacitors
Publikacja -
The PWM current source inverter with IGBT transistors and multiscalar model control system
PublikacjaW niniejszym artykule przedstawiono struktury układów sterowania maszyny indukcyjnej zasilanej z falownika prądu. Przedstawiono metodę modulacji szerokości impulsów dla falownika prądu. Pokazano modele matematyczne maszyny indukcyjnej klatkowej zasilanej z falownika prądu. Przedstawiono trzy układy regulacji sterowania multiskalarnego z czego dwa są nowe. Rozważania teoretyczne zweryfikowano za pomocą badań symulacyjnych.
-
The adaptive backstepping control of PMSM supplied by current source inverter for the field weakening region
PublikacjaThe sensorless control system of permanent magnet synchronous motor PMSM supplied by current source inverter for field weakening operation is presented in this paper. The adaptive backstepping control system and the backstepping speed observer are presented. The control system is based on multi-scalar variables. The control variables are: dc-link voltage and the output current vector pulsation. The control system was named voltage...
-
The Adaptive Backstepping Control of Permanent Magnet Synchronous Motor Supplied by Current Source Inverter
Publikacja...
-
Control Strategy of a Five-Phase Induction Machine Supplied by the Current Source Inverter With the Third Harmonic Injection
PublikacjaIn the five-phase induction machine (IM), it is possible to better use the electromagnetic circuit than in the three-phase IM. This requires the use of an adequate converter system which will be supplied by an induction machine. The electric drive system described, in this article, includes the five-phase induction machine supplied by the current source inverter (CSI). The proposed novelty—not presented previously—is the control...
-
Control of induction machine supplied by a current source inverter using the multi-scalar transformation and backstepping approach
PublikacjaThe paper describes the voltage control technique of squire-cage induction machines supplied by a current source inverter. The control system is based on new transformation of the electric drive system (machine and inverter) state variables to the multi-scalar variables form. The backstepping approach is used to obtain the feedback control law. The control system contains the structure of the observer...
-
Przekształtnik prądu jako sterownik w układach napędowych z silnikami indukcyjnymi
PublikacjaThe circuits used for power conversion applied in drives with electric machines are classified into two groups: voltage source inverters (VSI) and current source inverters (CSI). Application of the current source inverter results in better properties of drive than application of voltage source inverter because there is no output filter. The development of power electronics and especially the IGBTs, in which on/off-times are very...
-
Simulation Studies of Control Systems for Doubly Fed Induction Generator Supplied by the Current Source Converter
PublikacjaThe control system for a Doubly Fed Induction Generator (DFIG) supplied by a grid-connected Current Source Converter (CSC) is presented in this paper. Nonlinear transformation of DFIG model to the multi-scalar form is proposed. The nonlinear control strategy of active and reactive power of DFIG is realized by feedback linearization. In the proposed control scheme, the DFIG model and CSI parameters are included. Two Proportional-Integral...
-
Przekształtniki tranzystorowe działające w trybie prądu trójkątnego
PublikacjaPrzekształtniki oparte na węgliku krzemu mogą być analizowane jako źródła napięcia lub prądu niezależnie od topologii przy odpowiednich parametrach filtru wyjściowego. Szczególnie interesujące są falowniki napięcia działające w trybie prądu trójkątnego. W referacie przedstawiono sterowanie trójfazowym falownikiem napięcia posiadającym właściwości źródła prądu. Pokazano, jak dobrać parametry filtru wyjściowego falownika. Oceniono...
-
Synteza bezczujnikowego sterowania maszyną indukcyjną klatkową zasilaną z falownika prądu
PublikacjaSynteza bezczujnikowego sterowania maszyną indukcyjną klatkową zasilaną z falownika prądu stanowi cel niniejszej monografii. Praca zawiera podstawowe informacje na temat modelowania układu napędowego z maszyną indukcyjną klatkową zasilaną z falownika prądu. Przedstawiono informacje na temat linearyzacji nieliniowych obiektów. Na pod-stawie metody syntezy strukturalnej opracowano nowe transformacje do postaci zmien-nych multiskalarnych,...
-
New type T-Source inverter
PublikacjaThis paper presents different topologies of voltage inverters with alternative input LC networks. The basic topology is known in the literature as a Z-source inverter (ZSI). Alternative passive networks were named by the authors as T-sources. T-source inverter has fewer reactive components in comparison to conventional Z-source inverter. The most significant advantage of the T-source inverter (TSI) is its use of a common voltage...
-
Marek Adamowicz dr hab. inż.
OsobyStopień naukowy doktora uzyskał w 2008 r. na Wydziale Elektrotechniki i Automatyki Politechniki Gdańskiej. W latach 2005 – 2011 pracował na Akademii Morskiej w Gdyni. W 2010 r. jako laureat programu NCBR LIDER wybrał Wydział Elektrotechniki i Automatyki Politechniki Gdańskiej jako jednostkę realizującą swój projekt z zakresu szerokopasmowych przyrządów półprzewodnikowych i ich zastosowań w elektrowniach wiatrowych. Od 2011 roku...
-
Comparison of Impedance-Source Networks for Two and Multilevel Buck–Boost Inverter Applications
Publikacjampedance-source networks are an increasingly popular solution in power converter applications, especially in single-stage buck-boost power conversion to avoid additional front-end dc-dc power converters. In the survey papers published, no analytical comparisons of different topologies have been described, which makes it difficult to choose the best option. Thus, the aim of this paper is to present a comprehensive analytical comparison...
-
New type T-Source inverter
Publikacja -
Feedback Control of Doubly-Fed Generator Connected to Current Source Converter
PublikacjaDoubly-fed induction generator (DFIG) system supplied by current source converter (CSC) is considered in this article. The DFIG can work in two independent modes: AC grid connection and stand-alone mode. The DFIG is connected to the ac grid directly through its stator and the CSC links the rotor side. In this mode, the active and reactive powers of the DFIG must be controlled. This article proposes two control system structures...
-
Hybridized Space-Vector Pulsewidth Modulation for Multiphase Two-Level Voltage Source Inverter
PublikacjaIn space vector pulsewidth modulation (SVPWM) algorithms for multiphase two-level voltage source inverters (VSI), the components of active vectors in all orthogonal spaces have to be calculated within the processor and stored in its memory. These necessitate intensive computational efforts of the processor and large memory space. This article presents a hybridized SVPWM for multiphase two-level VSI. In this algorithm, elements...
-
Optimized Space Vector Modulation strategy for five phase voltage source inverter with third harmonic injection
PublikacjaThis paper presents a simple and an effective SVM algorithm for five-phase Voltage-Source Inverters with the possibility to control independently the voltage vectors for fundamental and auxiliary orthogonal subspaces. The essential benefit is that output voltage is generated using only four active voltage vectors with limited numbers of switching. In the proposed solution, four active vectors are arbitrary chosen, independent of...
-
Errors in the analysis of series resonant inverter/converter assuming sinusoidal waveforms of voltage and current
PublikacjaIn this paper the theory and simulation results of the series resonant inverter / converter are presented. In this work the authors carried out a detailed comparative analysis of results obtained using the method of AC analysis in the steady state for the first harmonic with the results of computer simulation. The AC analysis under certain conditions can lead to errors disqualifying this method. In particular, these errors appear...
-
Modular high precision high current source for special applications — Simulation and verification
PublikacjaThis paper presents selected issues concerning realization of high precision high current source for special applications, where high demands of output parameters of such device are required. A new 80 kW prototype of modular high precision high current source is presented, where output current accuracy reaches 5x10-5. This paper presents also results of operation of the simulation model and of the prototype converter. In order...
-
MPPT and GMPPT Implementation for Buck-Boost Mode Control of quasi-Z-Source Inverter
PublikacjaThe focus is on the maximum power point tracking implementation for the buck-boost voltage mode control of a single-phase multilevel inverter based on a three-level neutral point clamped quasi-Z-source topology. To utilize shoot-through states only when boost function is needed and avoid it in the buck mode, two different control approaches are required. This work proposes merged control system which provides switching between...
-
Modeling of a Quasi-Resonant DC Link Inverter Dedicated to Common-Mode Voltage and Ground Current Reduction
PublikacjaIn this paper, the modeling methodology of the AC drive system with a Parallel Quasi-Resonant DC Link Inverter (PQRDCLI) is described. A presented modeling approach is an attractive tool used for the effective evaluation of a common-mode (CM) voltage and grounds current reduction methods. Designed models of inverter, induction machine (IM), and cable are simple, thus the methods for parameter extraction are not complicated. Verification...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Three-Level Z-Source Neutral-Point-Clamped Inverter
PublikacjaThe paper describes construction and the principles of activity, attributes and potential of 3-phase Z-type inverters. The paper focuses on the basic system and suggested 3-level system of a NPC type Z-inverter, which was elaborated by authors. Simplified theoretical analysis of both systems has been verified by detailed simulation research. In the last section of the article, the possibility to build multilevel Z- inverters based...
-
Control of voltage source inverter without dead-time effects.
PublikacjaW artykule zaproponowano metodę dokładnego generowania wektora napięcia o małej amplitudzie w falowniku napięcia. Zaprezentowano metodę modulacji szerokości impulsów, w której wyeliminowano koniecznosć wprowadzania czasów martwych oraz kompensacji ich wpływu na napięcie wyjsciowe przekształtnika
-
Output filter for voltage source inverter supplying induction motor
PublikacjaW artykule przedstawiono problemy związane z występowaniem składowej zerowej w falowniku napięcia. Jako rozwiązanie zastosowano filtr bierny składowej zerowej dodatkowo pełniący funkcję filtru sinusoidalnego. Filtr nie wprowadza zauważalnych przesunięć prądów i napięć na wejściu i wyjściu układu. Przedstawiono metodę doboru elementów filtru w prostokatnym układzie współrzędnych oraz wyniki badań symulacyjnych i eksperymentalnych....
-
Advanced current regulated PWM inverter with simplified load model.
PublikacjaW artykule przedstawionio nowy regulator prądu stojana silnika asynchronicznego zasilanego z falownika napięcia. Regulator wykorzystuje obliczenia siły elektromotorycznej silnika. Rozważonio wpływ zmian parametrów silnika na działanie regulatora. Wykorzystano uproszczony model silnika bez uwzględnienienia rezystancji stojana. Zastosowano stałą częstotliwość próbkowania prądu. Układ zrealizowania w programie symulacyjnym oraz na...
-
The Electrical Drive Systems with the Current Source Converter
Publikacja-
-
CCM and DCM operation analysis of cascaded quasi-Z-source inverter
Publikacja -
Bearing current path and pulse rate in PWM-inverter-fed induction
Publikacja -
Power control system structure of doubly‐fed induction generator connected to current source converter
PublikacjaThe power control system structures for a doubly-fed generator (DFIG) are proposed. The classical field oriented control and the feedback control with the multi-scalar variables were considered. The generator is working in the AC grid connection mode. The rotor side of the generator is connected to the current source converter (CSC); the stator is directly related to the AC grid. The static feedback linearization using the multi-scalar...
-
Sensorless control system of induction machine supplied by voltage source inverter with output filter
PublikacjaThe paper focuses on sensorless control of the induction machines supplied by inverter with the output filters. “The novel” idea of the speed observer which is based on the backstepping approach is shown. The standard structure of the exponential observer is extended by the integrators and additional Z vector. The simulation and experimental results validate the proposed solution.
-
Design of three-phase three-level CIC T-source inverter with maximum boost control
Publikacja -
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaPrzedstawiono nową metodę detekcji i lokalizacji uszkodzeń polegających na braku przewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne. Metoda jest rozszerzeniem, opracowanej wcześniej, metody wykorzystującej znormalizowane składowe stałe prądów obciążenia. Znormalizowane wartości średnie prądów powiązano z dodatkowymi wskaźnikami diagnostycznymi, które zawierają informacje o czasie trwania nieprzewodzenia...
-
Control Systems of an Induction and Synchronous Motor Supplied by Current Source Converter Working as Generator
Publikacja -
High step-up continuous input current LCCT-Z-source inverters for fuel cells
PublikacjaFalowniki typu Z (ZSI) przeznaczone są do układów wymagających szerokiej zmiany wzmocnienia napięciowego, np. w energetyce odnawialnej. Ostatnio zaproponowano w literaturze zmienione struktury - falowniki typu Trans-Z (TZSI) oraz typu T (TSI) - w których dzięki zastosowaniu dławików sprzężonych uzyskano lepsze wzmocnienie niż w ZSI. W tym artykule przedstawiono ideę rozszerzonej struktury TZSI. Zaproponowano dwie nowe struktury...
-
The determination and identification of stray current source influences on buried pipelines using time/frequency analysis
PublikacjaZaprezentowano metodę detekcji źródła interferencji prądów błądzących na rurociągach podziemnych w aglomeracjach miejskich z wykorzystaniem łącznej analizy czasowo-częstotliwościowej mierzonych sygnałów. Badania przeprowadzono na rurociągu podziemnym zlokalizowanym w sąsiedztwie dwóch trakcji elektrycznych: tramwajowej i kolejowej. Wyniki analiz zaprezentowano w formie spektrogramów, które ilustrują zmiany spektralnej gęstości...
-
Advances in CSI-fed induction motor drives
PublikacjaThe application of current source inverters (CSI)in induction motor (IM) drives offers a number of advantages,including: voltage boosting capability, natural shoot-throughshort-circuit protection and generation of sinusoidal voltages.The exact generation of sinusoidal voltages is possible thanks tothanks to the effect of the output ac filter capacitors and mayimprove the accuracy of sensorless IM control. The eliminationof high...
-
Five-phase induction motor drive with sine-wave filter
PublikacjaThe paper presents closed loop ac drive with 5 phase induction motor operating with voltage source inverter and sine wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed co ntrol can be applied. In the presence of output filter both control and estimation algorithms should be modified due to sine wave filter installation....
-
Long-term measurements from a photovoltaic power plant and meteorological stations at the Laboratory LINTE^2 of Gdańsk University of Technology
Dane Badawcze1) The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E). 2) The measurements have been collected from a photovoltaic power plant located on the roof of the laboratory, having total capacity...
-
New Alternative Passive Networks to Improve the Range Output Voltage Regulation of the PWM Inverters
PublikacjaThis paper presents different topologies of buck-boost converters with passive input networks that have alternative topologies; this is known in the literature as a Z-source inverter. Alternative passive networks were named by the authors as T-inverters; these improve output voltage regulation of the PWM inverters. T-inverter has fewer reactive components in comparison to conventional Z-source inverter. The most significant advantage...
-
Pulse-Width Modulation of Power Electronic DC–AC Converter
PublikacjaThe Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges in the industrial drive system, as well as their components, and control, current source inverter-based drives, PWM techniques for...
-
Voltage and frequency regulation of a standalone induction generator by reduced-rating power electronic compensators - comparative evaluation
PublikacjaIn this paper are considered two fundamental topologies of power electronic compensators for voltage and frequency control of a standalone self-excited induction generator (IG) system. These are voltage and current source inverter based shunt compensators with energy storage. The aim of this study is to assess main features of both topologies in dynamic and steady-state IG operation. The whole system is modelled with the aid of...
-
Conducted EMI Propagation Paths in DC-AC Hard Switching Converter
PublikacjaIn order to limit the electromagnetic interference (EMI) in power electronics devices, knowledge about the phenomena connected with EMI generation and propagation is necessary. This papers describes the propagation paths in the 3 phase voltage source inverter using wide-band simulation and laboratory test with the signal processing method Wiener filtering, where the transfer functions between voltage across switches and the perturbation...
-
High Performance Control of AC Drives with Matlab/ Simulink
PublikacjaExplore this indispensable update to a popular graduate text on electric drive techniques and the latest converters used in industry. The Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges...
-
Indirect Measurement of Motor Current Derivatives in PMSM Sensorless Drives
PublikacjaMotor current derivatives contain useful information for control algorithms, especially in sensorless electric drives. The measurement of motor current derivatives in electric motors supplied by voltage source inverter can be performed using di/dt transducers. However, in such a solution additional sensors have to be installed, e.g. Rogowski coils. Another approach is to measure current derivatives indirectly – by oversampling...