Filtry
wszystkich: 43
Wyniki wyszukiwania dla: FRONT THICKNESS
-
Study on effective front region thickness of PCM in thermal energy storage using a novel semi-theoretical model
PublikacjaThermal energy storage in mobile applications, particularly battery of electric vehicles, is currently gaining a lot of importance. In this paper, a semi-theoretical time-dependent mathematical model of the phase change in a double shell thermal energy storage module has been developed where the inner tube is a heat exchange surface. An effective front region thickness for the melting and solidification process has been studied....
-
A New Approach of Solidification Analysis in Modular Latent Thermal Energy Storage Unit Based on Image Processing
PublikacjaThe solidification process of RT18HC in a cylindrical shell and tube storage unit has been studied using a new methodology based on image processing. The main idea of the algorithm is to label the region of solidification and use statistical functions to calculate the dimensions of the solidification front over time. Said analysis includes two methods. The first method is to measure the solid fraction changes during solidification....
-
Fracture in Asymmetric Bonded Joints
PublikacjaAdhesion was studied in asymmetric bonded joints using fracture mechanics tests. The asymmetric bonded joints consist of two different type and/or thickness materials bonded by an adhesive. Mentions of asymmetric bonded joint tests employed so far are rare in the literature. They are imperfect and therefore are not standardized. Accordingly three new tests were introduced in this work to study bonded joints. The new metrological...
-
Photovoltaic phenomena in devices with perfluorozincphthalocyanine layer
PublikacjaThe course of photovoltaic phenomenon in organic photovoltaic cells utilizing thin layers of perfluorozincphthalocyanine was studied in few single and planar bilayer configurations. Mechanisms of photogeneration and recombination of free charge carriers were determined and active interfaces were localized. In case of single layer cells these interfaces were located at the front electrode/F16ZnPc junctions, whereas photogeneration...
-
A study of nighttime vehicle detection algorithms
Dane BadawczeThis dataset is from my master's thesis "A study of nighttime vehicle detection algorithms". It contains both raw data and preprocessed dataset ready to use. In the pictures below you can see how images were annotated.
-
Jumping Wave 2D Profiles
Dane BadawczeThe file contains 2D profiles obtained from a jumping wave study in front of the tool during burnishing of 1.0562 steel by the toroidal-cone tool. Burnishing speed 30.5 m/min, feed of burnishing 0.2mm/rev Force 550 and 800 N.
-
Underwater noise recorded in Hornsund Fjord, Spitsbergen, at the front of the Hans Glacier
Dane BadawczeThe data includes underwater noise recorded in Hornsund Fjord, Spitsbergen at the front of the Hans Glacier between 05/09/2013 and 30/09/2013. A description of the data is in the article
-
UAV Survey Images - 3D Model - Zukowo Church
Dane BadawczeDataset description: Raw images from photogrammetric survey. Object: Parafia Wniebowzięcia Najświętszej Maryi Panny w ŻukowieLocation: Żukowo, Pomorskie, Kartuski County, PolandDrone type: DJI Mavic Pro.Flight plan: CircleTarget Product: 3D ModelDate: 21.04.2018Direct georeferencing: yesMetadata data: yes/GPSGCP: NoGCP: No Camera Name: DJI FC220Model...
-
UAV Survey Images - orthophotomap - Zukowo City
Dane BadawczeDataset description: Raw images from photogrammetric survey.Location: Żukowo, Pomorskie, Kartuski County, PolandDrone type: DJI Mavic Pro.Flight plan: Single gridTarget Product: OrthophotomapDate: 22.04.2018Direct georeferencing: yesMetadata data: yes/GPSGCP: yes (description and location in file)\GCP: RTK Camera Name: DJI FC220Model type: PerspectiveImage...
-
Malignant neoplasm of breast - Female, 54 - Tissue image [9140730014147811]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant neoplasm of breast - Female, 54 - Tissue image [9140730014148001]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Malignant neoplasm of breast - Female, 54 - Tissue image [9140730014149491]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Ultrasonic wave propagation and digital image correlation measurements of steel bars under 3-point bending
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a bar under a 3-point bending test. The bar was made of steel and had a cross-section of 5.96 × 5.96 mm2 and a length of 200 mm. The three-point bending test was performed using a Zwick/Roell Z10 universal testing machine (UTM), with a distance between supports of 12 cm. The parameters...
-
Congenital malformations of other endocrine glands - Female, 33 - Tissue image [9200729571531051]
Dane BadawczeThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Congenital malformations of other endocrine glands - Female, 33 - Tissue image [9200729571533821]
Dane BadawczeThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Congenital malformations of other endocrine glands - Female, 33 - Tissue image [9200729571532211]
Dane BadawczeThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #3)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #1)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #4)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #2)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Sarcoidosis of other and combined sites - Female, 58 - Tissue image [1205063001303421]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sarcoidosis of other and combined sites - Female, 58 - Tissue image [12050630013037371]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sarcoidosis of other and combined sites - Female, 58 - Tissue image [12050630013036081]
Dane BadawczeThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Permanent traffic counting stations - Expressway S6 in Gdansk (dataset containing 5-min aggregated traffic data and weather information)
Dane BadawczeThe data includes traffic data from permanent traffic count station located on the expressway S6 in the Tri-City Agglomeration area in Poland. The data covers the three year period between 2014 and 2017 and one direction of traffic (southbound).
-
Ultrasonic wave propagation and digital image correlation measurements of polyolefin fibre-reinforced concrete beams under 3-point bending (beam B-002)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete beam under a 3-point bending test. The beams had dimensions 15 x 15 x 70 cm3. The beam B-Con was made of concrete without fibres (as the reference beam), while beams B-002, B-004, and B-006 were manufactured from the concrete mix containing 2 kg/m3, 4 kg/m3 and 6 kg/m3 of fibres,...
-
Ultrasonic wave propagation and digital image correlation measurements of polyolefin fibre-reinforced concrete beams under 3-point bending (beam B-Con)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete beam under a 3-point bending test. The beams had dimensions 15 x 15 x 70 cm3. The beam B-Con was made of concrete without fibres (as the reference beam), while beams B-002, B-004, and B-006 were manufactured from the concrete mix containing 2 kg/m3, 4 kg/m3 and 6 kg/m3 of fibres,...
-
Ultrasonic wave propagation and digital image correlation measurements of polyolefin fibre-reinforced concrete beams under 3-point bending (beam B-004)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete beam under a 3-point bending test. The beams had dimensions 15 x 15 x 70 cm3. The beam B-Con was made of concrete without fibres (as the reference beam), while beams B-002, B-004, and B-006 were manufactured from the concrete mix containing 2 kg/m3, 4 kg/m3 and 6 kg/m3 of fibres,...
-
Ultrasonic wave propagation and digital image correlation measurements of polyolefin fibre-reinforced concrete beams under 3-point bending (beam B-006)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete beam under a 3-point bending test. The beams had dimensions 15 x 15 x 70 cm3. The beam B-Con was made of concrete without fibres (as the reference beam), while beams B-002, B-004, and B-006 were manufactured from the concrete mix containing 2 kg/m3, 4 kg/m3 and 6 kg/m3 of fibres,...
-
Invasive breast carcinoma of no special type - Female, 50 - Tissue image [5310730015834281]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 50 - Tissue image [5310730015839351]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 50 - Tissue image [5310730015834251]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 50 - Tissue image [5310730015833761]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 50 - Tissue image [5310730015834171]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 50 - Tissue image [5310730015833531]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 50 - Tissue image [5310730015838231]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 50 - Tissue image [5310730015838711]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 50 - Tissue image [5310730015834391]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 50 - Tissue image [5310730015839211]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 50 - Tissue image [5310730015836851]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Very low resolution depth images of 200,000 poses
Dane BadawczeA dataset represents simulated images of depth sensor seeing a single human pose, performing 200,000 random gestures. The depth images as vectors of pixels are stored with ground truth positions of every relevant joint.
-
Investigation of low-temperature cracks on selected national roads and motorways in Poland 2020
Dane BadawczeThe dataset contains video investigation and records of 68 road sections in various parts of Poland. Videos were recorded with the use of two cameras: 1) mounted in front of measurement vehicle, which was focused on overall view of road and 2) which was focused on pavement surface. The records are categorized according to the ID of the section given...