Filtry
wszystkich: 17
Wyniki wyszukiwania dla: HERNIA IMPLANTS
-
Mechanical compatibility of implants used in hernia repair with abdominal wall
PublikacjaThe paper deals with a membrane model of a synthetic surgical mesh for treatment of abdominal hernia. The authors analyse the compatibility of two implant types with the human wall: Dualmesh Gore and Proceed. The finite element method is applied to simulate tjhe behavior of the proposed model. Due fact that recurrences are usually caused by connection failure, this study is focused on reaction forces in supports representing the...
-
Constitutive Modelling of Knitted Abdominal Implants in Numerical Simulations of Repaired Hernia Mechanics
PublikacjaThe paper presents a numerical approach to describe mechanical behavior of anisotropic textile material, which is a selected abdominal prosthesis. Two constitutive nonlinear concepts are compared. In the first one the material is considered composed from two families of threads (dense net model) and in the second one the material is homogeneous but anisotropic (as proposed by Gassel, Ogden, Holzapfel). Parameters of both models...
-
Mechanical properties of mosquito nets in the context of hernia repair
PublikacjaThe paper deals with issue of applying mosquito nets as implants in hernia repair, which have already been used in resource-poor developing countries. Uniaxial tensile tests have been conducted on polyester mosquito meshes in two orthogonal directions. Non-linear elastic constitutive laws parameters have been identified to be applied in dense net material models. Mechanical performance of tested mosquito nets has been compared...
-
Dynamics of mechanical model of implant-tissue system in ventral hernia repair
PublikacjaThe paper deals with a finite element modelling of implants in the problem of ventral hernia repair. The synthetic mesh implanted in the abdomen during surgery is here modelled as a membrane structure. Thesystem undergoes the internal abdominal pressure that occurs during the postoperative cough, the load identified in the literature as the main cause of the connection failure and hernia recurrence. The model can be used to estimate...
-
IMPLANT USED IN HERNIA REPAIR UNDER PHYSIOLOGICAL MOVEMENTS OF HUMAN ABDOMEN
PublikacjaThe study deals with the mechanical behaviour of implant used in repair of abdominal hernia. The influence of orientation of the orthotropic implants in different areas of abdominal wall is studied.
-
Physical and mathematical modelling of implant-fascia system in order to improve laparoscopic repair of ventral hernia
PublikacjaThis paper describes an investigation of biomechanical behaviour of hernia repair, which is focused on the selection of safe linking of certain type of implant with fascia in laparoscopic operation. The strength of various fixations of the implant to the fascia is analysed. Methods: The research is based on experimental observations of operated hernia model behaviour during a dynamic impulse load corresponding to post-operative...
-
Cough influence on fascia-mesh system built for a hernia repair - an experimental research
PublikacjaAn experimental approach to identify stronger and weaker fixation schemes in laparoscopic ventral hernia repair is presented in the paper. Two types of implants, whose mechanical properties are significantly different and five kinds of connectors are considered. Physical models of operated hernia have been built using those materials and porcine abdominal tissue. The models have been subjected to dynamic impulse load, similar to...
-
In vivo performance of intraperitoneal onlay mesh after ventral hernia repair
PublikacjaBackground: Ventral hernia repair needs to be improved since recurrence, postoperative pain and other complications are still reported in many patients. The behavior of implants in vivo is not sufficiently understood to design a surgical mesh mechanically compatible with the human abdominal wall. Methods: This analysis was based on radiological pictures of patients who underwent laparoscopic ventral hernia repair. The pictures...
-
Behaviour of orthotropic surgical implant in hernia repair due to the material orientation and abdomen surface deformation
Publikacjarelation to the different range of typical deformations observed in different directions and zones of abdomen surface due to the patients’ life activities, has a significant influence on the extreme junction forces in the mesh–tissue connections and hence the repair persistence. The finite element model of the orthotropic implant was developed, and the junction forces in the connections of tissue and mesh were studied. The kinematical...
-
Sensitivity analysis based on non-intrusive regression-based polynomial chaos expansion for surgical mesh modelling
PublikacjaThe modelling of a system containing implants used in ventral hernia repair and human tissue suffers from many uncertainties. Thus, a probabilistic approach is needed. The goal of this study is to define an efficient numerical method to solve non-linear biomechanical models supporting the surgeon in decisions about ventral hernia repair. The model parameters are subject to substantial variability owing to, e.g., abdominal wall...
-
Regression points in non-intrusive polynomial chaos expansion method and D-optimal design
PublikacjaThe paper addresses selected issues of uncertainty quantification in the modelling of a system containing surgical mesh used in ventral hernia repair. Uncertainties in the models occur e.g. due to variability of abdominal wall properties among others. In order to include them, a non-intrusive regression-based polynomial chaos expansion method is employed. Its accuracy depends on the choice of regression points. In the study a relation...
-
Stiffness change of abdominal prosthesis Optomesh™ under cyclic loading
PublikacjaAbdominal prostheses are used in humans for abdominal wall strengthening or reconstruction. From the mechanical point of view they are membranes, so their basic mechanical property is tensile stiffness. This property is experimentally identified for a selected implant, OptomeshTM. The obtained results are described herein. Uni-axial simple and cyclic tension tests are a basis for the analysis. Both kinds of tests allowed to distinguish...
-
Biomechanical causes for failure of the Physiomesh/Securestrap system
PublikacjaThis study investigates the mechanical behavior of the Physiomesh/Securestrap system, a hernia repair system used for IPOM procedures associated with high failure rates. The study involved conducting mechanical experiments and numerical simulations to investigate the mechanical behavior of the Physiomesh/Securestrap system under pressure load. Uniaxial tension tests were conducted to determine the elasticity modulus of the Physiomesh...
-
EXPERIMENTS AND SIMULATIONS FOR LAPAROSCOPICVENTRAL HERNIA REPAIR IMPROVEMENT
PublikacjaThe authors conducted a wide experimental and numerical study in order to determine effective approaches in the laparoscopic VH repair. At first the study covered identification of mechanical properties of the abdominal fascia, implants, tacks and transabdominalsutures. Basis on these data, the one and two-dimensional mathematical models were formulated and a number of numerical static and dynamic analyses were carried out. Then...
-
Is mesh fixation necessary in laparoendoscopic techniques for M3 inguinal defects? An experimental study.
Publikacjarepairs, in case of large direct hernias (M3) mesh fixation is recommended to reduce recurrence risk. Despite lack of highquality evidence, the recommendation was upgraded to strong by expert panel. The authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. Method The authors conducted...
-
Mechanical behaviour of the implant used in human hernia repair under physiological loads
PublikacjaIn laparoscopic operations of abdominal hernias some recurrences still take place, even when applying a surgical mesh. This is usually caused by a failure of the connection between the tissue and the implant. The study deals with the influence of an implant’s orientation on forces in joints, which connect the mesh to human tissues. In the paper, the implant is modelled as a membrane structure within framework of the Finite Element...
-
Mechanical behaviour of knit synthetic mesh used in hernia surgery
PublikacjaPurpose: There is a discussion in literature concerning mechanical properties and modelling of surgical meshes. An important feature of elastic modulus dependency on load history is taken into account in this paper, as implants are subjected to variable loading during human activity. The example of DynaMesh®-IPOM surgical implant is studied. Methods: The analysis is based on failure tension tests and cyclic loading and unloading...