Filtry
wszystkich: 24
Wyniki wyszukiwania dla: VARISTOR
-
Problems of varistor quality assessment during exploitation
PublikacjaVaristors are commonly used elements which protect power supply networks against high-voltage surges or lightning. Therefore, quality and endurance of these elements is important to avoid losses when an expensive laboratory equipment would not be protected from random overvoltages. Additionally, excessive leakage currents generate serious costs due to high energy consumption. The paper presents shortly properties of varistors that...
-
Resonant ultrasonic spectroscopy in high-voltage varistor spectroscopy
PublikacjaResonant spectroscopy is an effective non-destructive testing method focused on defects in tested objects. The testing procedure, based on the resonant pattern, allows rejection of the tested samples with defects which do not fit the pattern. A sweeping frequency method has been used to measure the spectrum of resonances in high-voltage varistors. As a result we can observe resonances that depend directly on inhomogeneity of the...
-
Quality assessment of varistor ZnO structures by resonant ultrasound spectroscopy
PublikacjaWarystory sa wytwarzane z tlenku cynku ZnO jako cylindrycznie uformowane struktury, a ich jakość zależy od zmieniających się uwarunkowań technologicznych na etapach formowania ich kształtu oraz spiekania. W związku z tym są one testowane w końcowej fazie produkcji, a elementy wadliwe się odrzuca. Proponujemy testowanie jakości struktur ZnO we wcześniejszej fazie ich wytwarzania w celu wyeliminowania elementów wadliwych z dalszej,...
-
Diagnostics of high-voltage varistor quality using resonant ultrasound spectroscopy
PublikacjaResonant spectroscopy is an effective nondestructive testing method focused on defects detection in tested objects. Resonance spectrum contains an information about the mechanical properties and particularly about the structural homogeneity of the whole object. A swept frequency method has been used to measure the selected resonant frequencies range. The system for measurement of resonant ultrasound spectroscopy of high-voltage...
-
Impedance spectra of ZnO varistor type 440 model A ver. M
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model A ver. M
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model A M ver. 93
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model A M ver. xx
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model 0 ver. 89
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model O ver. 68
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 100 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 440 model O ver. 68
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 10 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model O M ver. 89
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model O M ver. 65 13
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model O M ver. 65 60
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 10 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Diagnostics of zno varistors by means of nondestructive testing
PublikacjaStandard industrial testing of high-voltage varistors for surge arresters demands application of high voltages and intensive currents. Nondestructive methods for varistor quality and endurance evaluation have been proposed and described. They rely on the application of resonant ultrasound spectroscopy, electro-ultrasonic spectroscopy, noise measurement and nonlinearity testing at voltages lower than continuous operating range....
-
Application of infrared thermoography to non-contact testing of varistors
PublikacjaTesting of varistors using thermography was carried out in order to assess their protective properties against possible overvoltage phenomena in the form of high-level voltage surges. An advantage of the thermography technique is non-contact temperature measurement. It was proposed to assess the properties of varistors workingin electronic devices as protective elements, on the basis of estimating temperature increments on varist...
-
Diagnostics of high-voltage varistors by acoustic emission
PublikacjaWarystory, szeroko stosowane w ogranicznikach przepięć, powinny być testowane na końcowym etapie ich wytwarzania. Stosowane metody testowania wymagają użycia wysokich napięć i prądów o dużych natężeniach, co jest nidogodne, destrukcyjne i wymaga poboru relatywnie dużych pocy. W artykule zaproponowano zastosowanie analizy sygnału emisji akustycznej do predykcji jakości struktury warystora. Opisano system przygotowany do tej aplikacji,...
-
Third harmonic index as a diagnostic tool of high-voltage varistors
PublikacjaThe recommended methods for standard testing of high-voltage varistors demand application of high voltages and intensive currents that is inconvenient and needs extensive power consumption. These methods require metallization of the prepared ZnO structures that increases costs of testing. Another method of varistor quality and endurance evaluation by the third harmonic index measurement at relatively low voltage range has been...
-
Quality assessment of high voltage varistors by third harmonic index
PublikacjaHigh voltage varistors that consist of grained ZnO have to be tested before assembling into a surge arrester. The existing methods demand a usage of high voltages and intensive currents that is inconvenient, destructive and needs extensive power consumption. Additionally, these methods require metallization of the prepared varistor structures that increases costs. We propose another method of varistors quality assessments by a...
-
Application of Infrared Thermography to Non-Contact Testing of Varistors
Publikacja -
Classification of high-voltage varistors into groups of differentiated quality
PublikacjaThe research was aimed on defining a factor of quality for high-voltage varistors using Non-Destructive Testing (NDT) techniques, which could be applied during the production testing. The newly proposed parameter Q determined on the basis of the lowest resonant frequency fr measured within the preselected frequency range was taken into account. The parameter Q was defined for ZnO structures after firing, without metallized contacts....
-
Quality assessment of ZnO-based varistors by 1/f noise
PublikacjaNoise has been used as a diagnostic tool of surge arrester varistor structures comprising of ZnO grains of various type and size. The physical and electrical properties of the measured samples have been described. In the experimental study, the applied measurement system and the results of noise measurements for the selected structures of varistors designed for the continuous working voltage 280 V, 440 V and 660 V have been presented....
-
Quality assessment of low voltage surge arresters
PublikacjaUsers expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...
-
Leakage Current Measurements of Surge Arresters
PublikacjaThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...