wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: X-RAY COMPUTED TOMOGRAPHY
-
Use of X-Ray Computed Tomography for Ice Detection Applied to Organ Cryopreservation
Publikacja -
Ovarian tissue cryopreservation by stepped vitrification and monitored by X-ray computed tomography
Publikacja -
Assessment of the cryoprotectant concentration inside a bulky organ for cryopreservation using X-ray computed tomography
Publikacja -
An optimized controlled rate slow cooling protocol for bovine ovarian tissue cryopreservation by means of X-ray computed tomography
Publikacja -
Bimodal Nd-Doped LuVO4 Nanoprobes Functionalized with Polyacrilic Acid for X-Ray Computed Tomography and NIR Luminescent Imaging
Publikacja -
Application of the X-ray micro computed tomography to the analysis of the structure of polymeric materials
PublikacjaIn this paper the application of X-ray micro-computed tomography (micro-CT) as a non-destructive testing method of polymeric materials is presented. Increasing applicability of polymers in variedend-use industries such as automotive, building and construction, consumer goods, and packaging is propelling the growth of the global polymer processing market. However, controlling of the polymer structure is one of the most important...
-
Experimental investigations of fracture process in concrete by means of x-ray micro-computed tomography
PublikacjaW artykule pokazano doświadczalne wyniki badań procesu pękania w betonie stosując mikro-tomografię. Doświadczenia wykonano dla zginanych belek betonowych. Wyniki doświadczalne modelowano stosując MES na bazie modelu z degradacją sztywności sprężystej z nielokalnym osłabieniem. Beton symulowano jako materiał 4-fazowy. Uzyskano dobra zgodność wyników MES z doświadczeniami.
-
Mechanical and radiation shielding properties of concrete reinforced with boron--basalt fibers using Digital Image Correlation and X--ray micro--computed tomography
PublikacjaThe paper presents experimental investigations of the radiation shielding, mechanical and fracture properties of concrete reinforced with 5 kg/m3 of novel basalt fibers infused with boron oxide (BBF). However, further studies concerning other dosages i.e. 1 kg/m3, 10 kg/m3, 15 kg/m3 and 20 kg/m3 are currently carried out. Experiments with neutron source revealed that addition of BBF as a dispersed concrete reinforcement could improve...
-
Mechanical and fracture properties of concrete reinforced with recycled and industrial steel fibers using Digital Image Correlation technique and X-ray micro computed tomography
PublikacjaPaper presents investigation of fracture phenomenon in plain concrete and in concrete reinforced with both recycled steel fibers (RSF) and industrial steel fibers (ISF). The wedge splitting test (WST), which enables stable crack propagation for quasi-brittle materials, was carried out on 75 75 75 mm cube samples. Initially, fracture process zone development was investigated only on the surface of samples using Digital Image Correlation...
-
Monitoring the fracture process of concrete during splitting using integrated ultrasonic coda wave interferometry, digital image correlation and X-ray micro-computed tomography
PublikacjaThe paper deals with the continuous-time monitoring of mechanical degradation in concrete cubes under splitting. A series of experiments performed with integrated coda wave interferometry (CWI) and digital image correlation (DIC), supported with X-ray micro-computed tomography (micro-CT) is reported. DIC and micro-CT techniques were used to characterize the fracture process in detail. CWI method was proved to be effective in the...
-
Tome-lapse X-ray tomography imaging of flow patterns in versatile silo model
PublikacjaThe paper introduces a new versatile silo model that was especially designed for in situ X-ray tomography studies of silo discharge for various flow conditions, namely concentric and eccentric. The presented work focuses on organic granular materials where low fraction of short-grain white rice is mixed with spheroidal sorghum particles. The high-quality tomography images combined with adequate image processing strategy allows...
-
X-Ray Computer Tomography Study of Degradation of the Zircaloy-2 Tubes Oxidized at High Temperatures
PublikacjaThe investigations of high-temperature oxidation of zirconium alloys, applied for fuel pellets in nuclear power plants, are usually limited to oxidation kinetics, phase transformations and microstructural characterization. The purpose of this research was to characterize the degradation phenomena occurring within oxide layer and at the interface oxide/metal, on internal and external Zircaloy-2 tube...
-
Shear fracture of longitudinally reinforced concrete beams under bending using Digital Image Correlation and FE simulations with concrete micro-structure based on X-ray micro-computed tomography images
PublikacjaThe paper presents experimental and numerical investigations of the shear fracture in rectangular concrete beams longitudinally reinforced with steel or basalt bar under quasi-static three point bending. Shear fracture process zone formation and development on the surface of beams was investigated by Digital Image Correlation (DIC) whereas thorough analyses of 3D material micro-structure, air voids, width and curvature of shear...
-
Analysis of the bulk solid flow during gravitational silo emptying using X-ray and ECT tomography
PublikacjaW pracy przedstawiono wyniki pomiarów zmian koncentracji piasku bezkohezyjnego zachodzących w prostokątnym modelu silosu opróżnianym grawitacyjnie. Pomiary wykonano z zastosowaniem kontynualnego promieniowania rentgenowskiego oraz z użyciem tomografii pojemnościowej. Badania wykonano dla zróżnicowanego zagęszczenia początkowego piasku oraz różnego stopnia szorstkości ścian. Szczególny nacisk położono na zachowanie sie materiału...
-
Quantitative estimation of volume changes of granular materials during silo flow using X-ray tomography.
PublikacjaW artykule przedstawiono wyniki badań doświadczalnych nad zmianami objętościowymi materiału granulowanego podczas przepływu silosowego. Badania wykonano przy zastosowaniu tomografii rentgenowskiej. Wyniki porównano z wynikami doświadczalnymi przy zastosowaniu cyfrowej obróbki zdjęć płynącego materiału.
-
Selection of material for X-ray tomography analysis and DEM simulations: comparison between granular materials of biological and non-biological origins
PublikacjaPhysical properties and X-ray tomography images of five different granular materials: glass bead, glass grit, short grain white rice, sorghum and clay granules (Seramis) are investigated to select the most promising materials for numerical simulations and time-lapse X-ray tomography imaging. The examined materials represent granular materials of non-biological origin (glass bead, glass grit and Seramis) and granular plant materials...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #3)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #1)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #4)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #2)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...