ISSN:
eISSN:
Publisher:
Disciplines
(Field of Science):
- biomedical engineering (Engineering and Technology)
- chemical engineering (Engineering and Technology)
- civil engineering, geodesy and transport (Engineering and Technology)
- materials engineering (Engineering and Technology)
- mechanical engineering (Engineering and Technology)
- pharmacology and pharmacy (Medical and Health Sciences )
- chemical sciences (Natural sciences)
(Field of Science)
Ministry points: Help
Year | Points | List |
---|---|---|
Year 2024 | 40 | Ministry scored journals list 2024 |
Year | Points | List |
---|---|---|
2024 | 40 | Ministry scored journals list 2024 |
2023 | 70 | Ministry Scored Journals List |
2022 | 40 | Ministry Scored Journals List 2019-2022 |
2021 | 40 | Ministry Scored Journals List 2019-2022 |
2020 | 40 | Ministry Scored Journals List 2019-2022 |
2019 | 40 | Ministry Scored Journals List 2019-2022 |
2018 | 11 | B |
2017 | 11 | B |
2016 | 11 | B |
2015 | 11 | B |
2014 | 9 | B |
2013 | 9 | B |
2012 | 6 | B |
2011 | 6 | B |
2010 | 6 | B |
Model:
Impact Factor:
Publishing policy:
- License
- open in new tab
- Information on publishing policy
- https://content.sciendo.com/view/journals/adms/adms-overview.xml open in new tab
- Information on the conditions of self-archiving
- Included in license
- Is self-archiving allowed by the journal?
- Yes - with restrictions
- Information on research data policy
- n/a
- Months of embargo
- no embargo
- Additional information
-
Must link to journal homepage with DOI.
Self-archiving policy for article versions based on the Sherpa Romeo database.
Papers published in journal
Filters
total: 135
Catalog Journals
Year 2015
-
Project of hip joint endoprothesis for an individual patient with materials selection
PublicationThis work includes the hip replacement design, based on the patient's medical records, the description of creation process and materials used for individual components.
Year 2014
-
BIOMATERIALS AND IMPLANTS IN CARDIAC AND VASCULAR SURGERY - REVIEW
PublicationCurrently, on prosthesis in cardiac blood vessels and heart valves are used materials of animal or synthetic origin. For animal materials include, among others pericardial sac in which is the heart. Materials such as this (natural) are characterized by a remarkable biocompatibility within the human body, but their main disadvantage is the relatively low durability. In turn, synthetic materials, which include the austenitic chromium-nickel-molybdenum...
-
Comparative in vitro research of the Human Aortic Bioprosthesis
PublicationE valuate of the usefulness and reliability of structures based on the analysis of recorded parameters determining the flow through the Human Aortic Bioprosthesis (HAB) have been dealt with. By flow parameters changes determining the performance environment of prosthesis analyzed change of the motion dynamics of the valve leaflets as a function of pressure, thereby determining the degree of alignment of the prosthesis to the performance...
-
Electrochemical Characterization of Gelatine Derived Ceramics
PublicationNew materials obtained by pyrolysis of gelatine (G) and poly(1,2-dimethylsilazane) (PSN) (weight ratio: G/PSN 70/30) at temperatures 700 and 900 °C were characterized by SEM and Raman spectroscopy. The presence of ceramics influences on the cluster size of the materials. Electrochemical tests were performed by cyclic voltammetry and galvanostatic cyclic polarization. The capacity of G/PSN was 464 and 527 mAh/g for materials pyrolysed...
-
THE DETERMINATION OF ABRASION RESISTANCE OF SELECTED BIOMATERIALS FOR THE FRICTION PAIRS IN THE HIP JOINT ENDOPROSTHESIS
PublicationThe key requirement for the modern endoprosthesis is high durability of the friction components, which results in long and trouble-free operation in the human body. The durability of currently used endoprosthesis is often limited by tribological wear processes of friction components (e.g. between the head and the acetabular component in a hip joint endoprosthesis) [8, 19, 23, 24]. In order to compare the tribological wear, tribological...
-
The Effect of Welding Conditions on Mechanical Properties of Superduplex Stainless Steel Welded Joints
PublicationThe tests results of superduplex stainless steel welded joints made with a different heat input, using automatic submerged arc welding (SAW) and semi-automatic flux-cored arc welding (FCAW) have been presented. Metallographic examinations, the measurements of the ferrite content, the width of the heat affected zone (HAZ) and the hardness of the welds in characteristic areas have been performed. Significant differences in the amount of...
-
Weldability of S500MC Steel in Underwater Conditions
PublicationWet welding with the use of covered electrodes is one of the methods of underwater welding. This method is the oldest, the most economic and the most versatile. The main difficulties during underwater wet welding are: high cooling rates of the joint, the presence of hydrogen in the arc area and formation of hard martensitic structure in the weld. These phenomena are often accompanied by porosity of welds and large number of spatters,...
Year 2013
-
DEGRADATION OF GFRP MARINE LAMINATES WITH NANO PARTICLE MODIFIED COATINGS
PublicationWater absorption and surface blistering behaviour was studied for polyester-matrix laminates with SiO2 nanoparticle reinforced gel coats. Accelerated water immersion tests at 37°C showed that addition of 10% nanoparticles increases blisters incubation time by ca. 50% compared to 5% and 0% nanoparticles composites.
-
DYNAMIC MECHANICAL BEHAVIOUR OF GFRP COMPOSITES WITH SiO2 NANO PARTICLES REINFORCED EPOXY MATRIX
PublicationDynamic mechanic (DMA) tests were performed to compare the mechanical behaviour of glass fibre reinforced epoxy laminate composites with SiO2 nanoparticle reinforced matrix. The selection of the most promising nanoparticle concentrations was considered in terms of elastic modulus and glass transition temperature. The reference specimens (0% nanoparticles) did not contain diluent accordingly the results do not allow the exact comparison...
-
Novel Polyurethanes as Antifouling Paint Matrices
PublicationThe new poly(ester-ether urethane)s (PEEUR) were prepared in two stage synthesis from formerly obtained oligo(alkylene ester-ether)diols (OAEE) and 4,4‘-diphenylmethane diisocyanate (MDI). PEEUR samples were subjected to crosslinking with styrene in the presence of radical polymerization initiators: methyl ethyl ketone peroxide (MEKPO) or cobalt 2-ethyl cyclohexanoate (EtHCo). Crosslinked PEEUR were characterized by their physicochemical...
Year 2012
-
Bioactive core material for porous load-bearing implants
PublicationSo far state of knowledge on biodegradable materials is reviewed. Among a variety of investigated materials, those composed of polymers and ceramics may be considered as only candidates for a core material in porous titanium alloy. The collagen and chitosan among natural polymers, polyhydroxy acids among synthetic polymers, and hydroxyapatite and tricalcium phosphate among ceramics are proposed for further research. Three essential...
-
Environmental degradation of titanium alloy in artificial saliva
PublicationThe titanium and its alloys are potentially prone to hydrogen embrittlement, including those proposed for dental implants. The research has been aimed to assess a susceptibility to environment-enhanced degradation of the Ti-13Zr-13Nb alloy in artificial saliva with or without hydrofluoric acid, subject or not to cathodic polarisation. The results have shown that even if artificial saliva is safe environment, both cathodic polarization...
-
Water sorption and blistering of GFRP laminates with varying structures
PublicationThe microstructures, water absorption as well as blistering was studied for bi- and tri- axial glass fibre vinyl ester and polyester -matrix laminates coated with gel coat layer and uncoated. The effect of manufacturing technique on water sorption characteristics was considered. It was found that water sorption characteristics of GFRP depend on manufacturing methods. The least water intake was found for specimens having perfect...
Year 2011
-
Corrosion resistance examinations of Ti6Al4V alloy with the use of potentiodynamic method in Ringer`s and artificial saliva solutions
PublicationThe research results of corrosion resistance of the Ti6Al4V alloy in the simulated body fluids (SBF) are presented. The polished specimens have shown better corrosion resistance than grinded surfaces in both liquids. The artificial saliva has revealed more aggressive test solution than Ringer`s solution. The pitting tendency has been observed in Ringer`s solution for grinded specimens.
-
Influence of pore formers on electrical properties of CaTi0.9Fe0.1O3-δ perovskite-type ceramics
PublicationPorous CaTi0.9Fe0.1O3-δ (CTF) perovskites were synthesized by the standard solid state method at different sintering temperatures with carbon black (CB), corn starch (CS) and potato starch (PS) as pore-forming agents. The ceramic samples of porosity between 9% and 42% with 5 - 40 μm pore sizes, were obtained by a 6 h sintering at either 1130º C or 1200º C of precursor powder prepared at 1470º C. X-ray diffraction analysis proved...
-
Modeling by finite element methods of impact of erosion on frequency of normal modes of L-0 blade
PublicationAfter some time of exploitation steam turbine rotors blades in energetic industry they are being eroded and also their frequency of normal modes is changed. Those changes can cause to unwanted shift of blades normal mode frequencies. It is necessary to find quick method of rating changes of frequency in connection of mass loss due erosion. The evaluation of this dependence was made by finite element modeling method using HyperWorks...
-
Nanotechnologies in Development of Structural Materials and Biomaterials
PublicationThe nanometric materials and technologies resulted in nanostructures are reviewed. The examples of nanomaterials are shown. The typical nanotechnologies, including plastic deformation, mechanical attrition, controlled detonation, hot plasma jet synthesis, laser vaporisation, CVD and PVD, mechanical milling, annealing, ultrasonic irradiation, nanolithography, electrocrystallisation, electrospinning, sol-gel method, cryogenic laser-enhanced...
-
Nanotubular Titanium Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublicationThe present paper describes the techniques to improve the bioactivity of titanium and enhance the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotube arrays (TiO2).
-
On degradation of glass/polyester laminate immersed in water
PublicationMechanical behaviour was compared for glass/ polyester laminates manufactured in the boatbuilding plant using three methods: hand lay-up, vacuum bagging, infusion. Specimens were tested in dry condition and following accelerated water immersion test (70°C- corresponding to the exposure of 30 years at 19°C). In three point bending test 40-50% reduction in laminate strength was observed due to water immersion. The highest degradation...
-
Porous biomaterial for orthopaedic implants based on titanium alloy
PublicationTytan i jego stopy są szeroko stosowane jako biomateriały dla zastosowań ortopedycznych. Badania związane z ich najlepszą odpornością na korozję i ścieranie, biozgodnością i bioaktywnością są stale prowadzone. Obecne badania koncentrują się również na projektowaniu i produkcji materiałów porowatych w oparciu o stopy np. Ti-13Nb-13Zr, które mogą być stosowane do wytwarzania implantów. Jedną z najbardziej efektywnych metod wytwarzania...
seen 2182 times