Search results for: CAST-IN-PLACE CONCRETE
-
Prediction of cast-in-place concrete strength of the extradosed bridge deck based on temperature monitoring and numerical simulations
PublicationThe work is devoted to the implementation of a monitoring system for high performance concrete embedded in the span of an extradosed bridge deck using a modified maturity method augmented by numerical simulations conducted by the authors’ FEM code. The paper presents all research stages of bridge construction and considers the conclusions drawn from the results of laboratory tests, field measurements, and numerical calculations....
-
Determination of Thermophysical Parameters Involved in The Numerical Model to Predict the Temperature Field of Cast-In-Place Concrete Bridge Deck
PublicationThe paper dealswith a concept of a practical computationmethod to simulate the temperature distribution in an extradosed bridge deck. The main goal of the study is to develop a feasible model of hardening of concrete consistent with in-situ measurement capabilities. The presented investigations include laboratory tests of high performance concrete, measurements of temperature evolution in the bridge deck and above all, numerical...
-
Concrete elements cast in febric forms
PublicationPrzedstawiono wyniki badań wytrzymałościowych elementów betonowych wylewanych w wiotkich formach wykonanych z materiałów syntetycznych. Badania przeprowadzono dla modelu ściany/słupa. Zbadano mechaniczne i chemiczne własności 10 różnych materiałów syntetycznych. Wybrano materiał o przepuszczalności umożliwiającej wykonanie monolitycznej konstrukcji. Z 12 zbadanych mieszanek betonowych do dalszej analizy wyselekcjonowano trzy. Badania...
-
Model tests of cast-in-place piles formed by using different types of auger
PublicationModel tests are still a popular research tool used to observe and determine the mechanisms of pile-soil interaction. Due to the significant scale effect, the results of model tests performed in the 1g system can only be analysed from the qualitative side. This article describes and presents the results of 1g pile model tests carried out for comparative purposes. There were tested the effectiveness and efficiency of various types...
-
Maturity curve for estimating the in-place strength of high performance concrete
PublicationThe paper presents the maturity curve for estimating the in-place early-age compressive strength of concrete. The development of appropriate maturity curve is a complex process. It is important to correctly determine the datum temperature and activation energy, which can be obtained in mortar tests. This paper describes an investigation of the accuracy of the maturity method to estimate the strength when different way to rate constant...
-
Insight into the microstructural and durability characteristics of 3D printed concrete: Cast versus printed specimens
PublicationThis study presents the comparison of microstructural and durability characteristics of 3D printed concrete (3DPC) depending on its production method (printing or casting). Printed samples with different numbers of layers, as well as a cast specimen with an identical mix composition, were produced and compared, with their microstructural pore and solid characteristics quantitatively and qualitatively investigated. For this purpose,...
-
FEM and experimental investigations of concrete temperature field in the massive stemwall of the bridge abutment
PublicationThe paper deals with the prediction of early-age concrete temperature of cast-in-place stemwall of the bridge abutment. The considered object is an arch bridge located in Gda´nsk. In the case of massive structures, it is particularly important to not exceed the temperature difference between the core and the concrete surface. Too high temperature gradient generates an increase in thermal stresses, what could be the reason of exceeding...
-
Isothermal Calorimetry and Compressive Strength Tests of Mortar Specimens for Determination of Apparent Activation Energy
PublicationThe hydration process of cementitious materials involves a thermally activated reaction that depends on the composition of the mixture and the curing temperature. The main parameter affecting the temperature variation of cast-in-place concrete is the apparent activation energy, which can be used for the efficient prediction of the temperature evolution and maturity index of hardening concrete. This paper discusses two methods to...
-
Conservation aspects of cast-iron platform shelters on the example of Vistula Pomerania railway stations
PublicationCast-iron shelters were used in the 19th century as cheaper alternatives to large platform halls. Nevertheless, they were aesthetically distinguishable from later riveted solutions. Because of their durability and continuous utility, they were not the subject of disassembly, as numerous transport infrastructure objects have been in recent decades. This article aims to indicate proper conservation practices during construction works...
-
3D X-ray Micro-CT Analysis of Rebar Corrosion in Reinforced Concrete Subjected to a Chloride-Induced Environment
PublicationThe paper presents experimental investigations of the concrete cover protective ability to coun-teract rebar corrosion in reinforced concrete cubes. To study and quantify the consequences of corrosion a reinforced concrete sample was subjected to chloride-induced environment in order to get corroded and combined with un-corroded sample. Chloride-accelerated technique can in-duce a high degree of corrosion within at a controlled...