Filters
total: 238
filtered: 231
-
Catalog
Chosen catalog filters
Search results for: COLLECTION EFFICIENCY
-
Collection Efficiency in Narrow Electrostatic Precipitators with a Longitudinal or Transverse Wire Electrode
PublicationRecently narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application in diesel engine exhaust systems. In this work, results of particle collection efficiency measurements in narrow electrostatic precipitators for negative and positive dc voltage polarity are presented. The ESP usedin this work was a parallelepiped equipped with wire discharge electrode and two collecting plate-electrodes....
-
Collection efficiency in narrow electrostatic precipitators with a longitudinal or transverse wire electrode
Publication -
Electrohydrodynamic flow patterns and collection efficiency in narrow wire-cylinder type electrostatic precipitator
PublicationRecently, narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application for the cleaning of the exhaust gases emitted by diesel engines. Diesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. Therefore,...
-
Electrohydrodynamic secondary flow and particle collection efficiency in spike-plate multi-electrode electrostatic precipitator
PublicationIn this work the results of electrohydrodynamic (EHD) secondary flow measurements in a spike-plate type electrostatic precipitator (ESP) are presented. In the investigated ESP two-sided and one-sided spike electrodes were used as a discharge electrodes. The results of 2D PIV measurements showed that flow pattern obtained for a different spike tips positions in respect to the primary flow direction significantly changing the flow...
-
Electrohydrodynamic Secondary Flow and Particle Collection Efficiency in Spike-Plate Multi-Electrode Electrostatic Precipitator
PublicationIn this work the results of electrohydrodynamic (EHD) secondary flowmeasurements in a spike-plate type electrostatic precipitator (ESP) are presented. In the investigated ESP two-sided and one-sided spike electrodes were used as a discharge electrodes. The results of 2D PIVmeasurements showed that flow pattern obtained for a different spike tips positions in respect to the primary flow direction significantly changing the flow...
-
Electrohydrodynamic flow and particle collection efficiency in a one-sided spike-plate type electrostatic precipitator
Publication -
Electrohydrodynamic Secondary Flow and Particle Collection Efficiency in a One-sided Spike-plate Type Electrostatic Precipitator
PublicationIn this work, results of electrohydrodynamic secondary flow and particle collection efficiency measurements in an electrostatic precipitator under positive and negative voltage polarity are presented. The electrostatic precipitator had two plate collecting electrodes and a single spike discharge electrode. The spike tips were only on one side of the discharge electrode, therefore called a one-sided spike electrode. The electrohydrodynamic...
-
Influence of Toll Collection Method on Motorways on Traffic Safety and Efficiency
PublicationThe paper presents the results of the effectiveness analysis for various forms of toll collection on motorway gates and their impact on safety and efficiency of traffic. The results from field tests that were performed on the A1 motorway in Rusocin were used for the analysis. The research included the analysis of the video image of driver behaviour on the way to the toll booths and at toll booths. The PTV VISSIM tool was used to...
-
Evaluation of the efficiency of the duty cycle of refuse collection vehicle based on real-world data
PublicationIn this paper a method of the efficiency evaluation of the duty cycle of Refuse Collection Vehicle is presented. Using real world data, two representative duty cycles were analysed. Total cycle efficiency was calculated, as well as the efficiency of particular cycle phases. Then, energy needed to collect and compact the waste and energy from fuel were compared. Measured and calculated values were shown on the diagrams illustrating...
-
Energetic model of hydraulic system of refuse collection vehicle based on simulation and experimental data
PublicationThis paper presents an energetic model of hydraulic system of a refuse collection vehicle. First, benefits resulting from implementation of an energetic model in the industry and operation of a Refuse Collection Vehicle are briefly explained. Then, components of the energy consumption in hydraulic circuits of compactor and lifting device are described and combined into a comprehensive model that can be evaluated using basic measurement...
-
Urban dew formation efficiency and chemistry in Poland
PublicationThe measurements of dew formation efficiency and chemistry were performed in Poland in September 2009, as a part of a longer, two-year sampling campaign. Pairs of sites, representing centers of major Polish cities and rural conditions in three different regions, were compared. With the aim to get more detailed landuse-oriented characteristics of dew, two additional sites were set close to Wroclaw. Collection of dew at each site...
-
Artificial intelligence support for disease detection in wireless capsule endoscopy images of human large bowel
PublicationIn the work the chosen algorithms of disease recognition in endoscopy images were described and compared for theirs efficiency. The algorithms were estimated with regard to utility for application in computer system's support for digestive system's diagnostics. Estimations were achieved in an advanced testing environment, which was built with use of the large collection of endoscopy movies received from Medical University in Gdańsk....
-
Pre-analytical aspects in metabolomics of human biofluids – sample collection, handling, transport, and storage
PublicationMetabolomics is the field of omics research that offers valuable insights into the complex composition of biological samples. It has found wide application in clinical diagnostics, disease investigation, therapy prediction, monitoring of treatment efficiency, drug discovery, or in-depth analysis of sample composition. A suitable study design constitutes the fundamental requirements to ensure robust and reliable results from the...
-
Electrohydrodynamic secondary flow in the electrostatic precipitator with spiked electrodes
PublicationIn this work, the results of electrohydrodynamic (EHD) secondary flow measurements in an electrostatic precipitator (ESP) with one-sidedspike electrodes are presented. The EHD secondary flow was measured for one-sided spike electrodes with the spike tips directed either upstream or downstream the primary flow. The results showed different flow patterns for different spike tips direction in respect to the primary flow direction....
-
Ocena sprawności cyklu roboczego Pojazdu do Usuwania Odpadów z Pojemników na podstawie danych eksploatacyjnych
PublicationW artykule przedstawiona została metoda oceny sprawności cyklu roboczego śmieciarki. Wykorzystując dane eksploatacyjne wyznaczono dwa reprezentatywne cykle i na ich podstawie obliczono zarówno sprawność całego cyklu, jak i jego poszczególnych faz. Porównano wartości energii potrzebnej do opróżniania pojemników, energii do zagęszczania odpadów oraz energii z paliwa. Przedstawiono przebiegi mierzonych i obliczonych wartości w czasie...
-
Electrohydrodynamic Flow Patterns in a Narrow Electrostatic Precipitator with Longitudinal Wire Electrode for Various Electrode Geometries
PublicationRecently narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application in diesel engines. In this paper results of 2-dimensional (2D) Particle Image Velocimetry (PIV) measurements of the flow patterns in a narrow ESP for a various electrode geometries are presented. The PIV measurements were carried out in the observation plane that is perpendicular to the ESP duct. The ESP was...
-
Investigation of Narrow Transverse and Longitudinal Electrostatic Precipitators
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of...
-
New approach for e-cigarette aerosol collection by an original automatic aerosol generator utilizing melt-blown non-woven fabric
PublicationCurrently, there is lack of standardized conditions for the collection and analysis of e-cigarette (EC) aerosol. Considering the urgent need for the development of these guidelines, a procedure for EC aerosol analysis was developed. A novel automatic e-cigarette aerosol generator was designed. For the first time, melt-blown non-woven fabric was applied for the effective uptake of compounds released from vaporized e-liquid. The...
-
Towards automation of IT systems repairs
PublicationMonitoring and repair are two sides of the on-the-fly maintenance of IT systems.Monitoring is well supported by automatic tools. In contrast, repairs involve much higherhuman intervention which negatively affects reliability and efficiency. The paper intro-duces a method of automating repairs of IT systems which can be integrated with any ofthe existing monitoring mechanisms. The method is described as a collection of modelsand...
-
comparison of circular and rectangular narrow esps with longitudinal wire electrode
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of...